欧美成人免费电影,国产欧美一区二区三区精品酒店,精品国产a毛片,色网在线免费观看

參數(shù)資料
型號(hào): AD7675AST
廠商: ANALOG DEVICES INC
元件分類: ADC
英文描述: 16-Bit, 100 kSPS, Differential ADC
中文描述: 1-CH 16-BIT SUCCESSIVE APPROXIMATION ADC, SERIAL/PARALLEL ACCESS, PQFP48
封裝: 1.40 MM HEIGHT, PLASTIC, MS-026BBC, LQFP-48
文件頁(yè)數(shù): 14/20頁(yè)
文件大小: 399K
代理商: AD7675AST
REV. 0
AD7675
14
t
9
RESET
DATA
BUSY
CNVST
t
8
Figure 12. RESET Timing
For other applications, conversions can be automatically initi-
ated. If
CNVST
is held low when BUSY is low, the AD7675
controls the acquisition phase and then automatically initiates a
new conversion. By keeping
CNVST
low, the AD7675 keeps
the conversion process running by itself. It should be noted that
the analog input has to be settled when BUSY goes low. Also, at
power-up,
CNVST
should be brought low once to initiate the
conversion process. In this mode, the AD7675 could sometimes
run slightly faster than the guaranteed limit of 100 kSPS.
DIGITAL INTERFACE
The AD7675 has a versatile digital interface; it can be interfaced
with the host system by using either a serial or parallel interface.
The serial interface is multiplexed on the parallel data bus. The
AD7675 digital interface also accommodates both 3 V or 5 V
logic by simply connecting the OVDD supply pin of the AD7675
to the host system interface digital supply. Finally, by using the
OB/
2C
input pin, either two’s complement or straight binary
coding can be used.
The two signals
CS
and
RD
control the interface. When at least
one of these signals is high, the interface outputs are in high
impedance. Usually,
CS
allows the selection of each AD7675 in
multicircuits applications and is held low in a single AD7675
design.
RD
is generally used to enable the conversion result on
the data bus.
CNVST
BUSY
DATA
BUS
CS
=
RD
= 0
PREVIOUS CONVERSION DATA
NEW DATA
t
1
t
10
t
4
t
3
t
11
Figure 13. Master Parallel Data Timing for Reading
(Continuous Read)
PARALLEL INTERFACE
The AD7675 is configured to use the parallel interface (Figure 13)
when the SER/
PAR
is held low. The data can be read either
after each conversion, which is during the next acquisition
phase, or during the following conversion as shown, respectively,
in Figure 14 and Figure 15. When the data is read during the
conversion, however, it is recommended that it be read-only
during the first half of the conversion phase. That avoids any
potential feedthrough between voltage transients on the digital
interface and the most critical analog conversion circuitry.
DATA
BUS
t
12
t
13
BUSY
CS
RD
CURRENT
CONVERSION
Figure 14. Slave Parallel Data Timing for Reading
(Read after Convert)
CS
= 0
CNVST,
RD
t
1
PREVIOUS
CONVERSION
DATA
BUS
t
12
t
13
BUSY
t
4
t
3
Figure 15. Slave Parallel Data Timing for Reading (Read
During Convert)
The BYTESWAP pin allows a glueless interface to an 8-bit bus.
As shown in Figure 16, the LSB byte is output on D[7:0] and
the MSB is output on D[15:8] when BYTESWAP is low. When
BYTESWAP is high, the LSB and MSB bytes are swapped and
the LSB is output on D[15:8] and the MSB is output on D[7:0].
By connecting BYTESWAP to an address line, the 16-bit data
can be read in two bytes on either D[15:8] or D[7:0].
CS
RD
BYTE
PINS D[15:8]
PINS D[7:0]
HI-Z
HI-Z
HIGH BYTE
LOW BYTE
LOW BYTE
HIGH BYTE
HI-Z
HI-Z
t
12
t
12
t
13
Figure 16. 8-Bit Parallel Interface
相關(guān)PDF資料
PDF描述
AD7675ASTRL 16-Bit, 100 kSPS, Differential ADC
AD7676 16-Bit +-1 LSB INL, 500 kSPS, Differential ADC
AD7676AST 16-Bit +-1 LSB INL, 500 kSPS, Differential ADC
AD7676ASTRL 16-Bit +-1 LSB INL, 500 kSPS, Differential ADC
AD7677 16-Bit, 1 LSB INL, 1 MSPS Differential ADC
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
AD7675ASTRL 制造商:Analog Devices 功能描述:ADC Single SAR 100ksps 16-bit Parallel/Serial 48-Pin LQFP T/R 制造商:Analog Devices 功能描述:ADC SGL SAR 100KSPS 16BIT PARALLEL/SERL 48LQFP - Tape and Reel
AD7675ASTZ 功能描述:IC ADC 16BIT DIFF INP 48LQFP RoHS:是 類別:集成電路 (IC) >> 數(shù)據(jù)采集 - 模數(shù)轉(zhuǎn)換器 系列:PulSAR® 其它有關(guān)文件:TSA1204 View All Specifications 標(biāo)準(zhǔn)包裝:1 系列:- 位數(shù):12 采樣率(每秒):20M 數(shù)據(jù)接口:并聯(lián) 轉(zhuǎn)換器數(shù)目:2 功率耗散(最大):155mW 電壓電源:模擬和數(shù)字 工作溫度:-40°C ~ 85°C 安裝類型:表面貼裝 封裝/外殼:48-TQFP 供應(yīng)商設(shè)備封裝:48-TQFP(7x7) 包裝:Digi-Reel® 輸入數(shù)目和類型:4 個(gè)單端,單極;2 個(gè)差分,單極 產(chǎn)品目錄頁(yè)面:1156 (CN2011-ZH PDF) 其它名稱:497-5435-6
AD7675ASTZRL 功能描述:IC ADC 16BIT DIFF INP 48LQFP RoHS:是 類別:集成電路 (IC) >> 數(shù)據(jù)采集 - 模數(shù)轉(zhuǎn)換器 系列:PulSAR® 標(biāo)準(zhǔn)包裝:1,000 系列:- 位數(shù):12 采樣率(每秒):300k 數(shù)據(jù)接口:并聯(lián) 轉(zhuǎn)換器數(shù)目:1 功率耗散(最大):75mW 電壓電源:單電源 工作溫度:0°C ~ 70°C 安裝類型:表面貼裝 封裝/外殼:24-SOIC(0.295",7.50mm 寬) 供應(yīng)商設(shè)備封裝:24-SOIC 包裝:帶卷 (TR) 輸入數(shù)目和類型:1 個(gè)單端,單極;1 個(gè)單端,雙極
AD7676 制造商:AD 制造商全稱:Analog Devices 功能描述:16-Bit +-1 LSB INL, 500 kSPS, Differential ADC
AD7676ACP 制造商:Analog Devices 功能描述:ADC SGL SAR 500KSPS 16BIT PARALLEL/SERL 48LFCSP - Trays