Power entry modules without line filter
8842/8843
Connectors
IEC Appliance Inlet C14 with Fuseholder 2-pole
Plug removal necessary for fuse
replacement
C14
70° C
C18
70° C
Description
-PanelMount:
Screw-onmountingfromfrontside
-2Functions:
ApplianceInletprotectionclassIorII,Fuseholderforfuse-links
5x20mm,1-or2-pole
-Quickconnectterminals4.8x0.8mm
Approvals
-VDECertificateNumber:77560
-ULFileNumber:E93617
-CSAFileNumber:70111
Characteristics
-Allsingleelementsarealreadywired
-Withslottedscrewtypefuseholder
FuseholdermeetsrequirementsofmedicalstandardIEC/EN60601-1
Thefuseholdercanonlybeopenedwiththeaidofatool
Thefuseholderisaccessiblefromtheequipmentfront
-QualifiedforuseinequipmentaccordingIEC/EN60950
References
Werecommendfornewapplicationsthenewtype
4707Weblinks
Technical Data
RatingsIEC
10A/250VAC;50Hz
RatingsUL/CSA
6A/250VAC;60Hz
DielectricStrength
>2kVACbetweenL-N
>4kVACbetweenL/N-PE
(1min/50Hz)
AllowableOperationTemp.
-25°Cto70°C
DegreeofProtection
fromfrontsideIP40acc.toIEC60529
ProtectionClass
Suitableforapplianceswithprotection
class1or2acc.toIEC61140
Terminal
Quickconnectterminals4.8x0.8mm
PanelThicknesss
Screw:max6mm
Mountingscrewtorquemax0.5Nm
Material:Housing
Thermoplastic,UL94V-0
ApplianceInlet
C14acc.toIEC/EN60320-1,
UL498,CSAC22.2no.42(forcold
conditions)pin-temperature70°C,10A,
ProtectionClass1or2
Fuseholder
1or2pole,ShocksafecategoryPC2
acc.toIEC60127-6,
forfuse-links5x20mm
RatedPowerAcceptance@
Ta23°C
5x20:1.6W(1pole)/1,2W(2-pole)
perpole
PowerAcceptance@Ta>
23°C
Admissiblepoweracceptanceathig-
herambienttemperatureseederating
curves
Dimensions
50mm
max. R1.5
M3
33.3
40
3.2
6.2x90
50
40
37.5
26.5
6
32.5
+0.2
0
+0.2 0