391
www.littelfuse.com
2AG
Fast-Acting Fuse 2206P Series
PACKAGING OPTIONS:
2206P Series available on Tape and Reel
per EIA-296. 2206 series available in bulk packaging. For 1000 pieces
bulk, add packaging suffix MXP.
ENVIRONMENTAL SPECIFICATIONS:
Operating Temperature:
–55°C to 125°C.
Shock:
MIL-STD-202, Method 213, Test Condition I
(100 G’s peak for 6 milliseconds).
Vibration:
MIL-STD-202, Method 201 (10–55 Hz, 0.06 inches
total excursion).
Salt Spray:
MIL-STD-202 Method 101, Test Condition B (48 hours).
Insulation Resistance (After Opening): MIL-STD-202, Method 302,
Test Condition B.
Resistance to Soldering Heat:
(Axial Leaded Fuses):
MIL-STD-202, Method 210A, Test Condition B (260°C, 3 Seconds).
Thermal Shock:
MIL-STD-202, Method 107,
Test Condition B (–65°C to 125°C).
Moisture Resistance:
MIL-STD-202, Method 106
(90-98% RH, 65°C).
Solderability:
(Axial Leaded Fuses): MIL-STD-202,
Method 208.
PHYSICAL SPECIFICATIONS:
Materials:
Glass Body, Nickel-Plated Brass Fuse Caps.
(Insulating sleeve option available).
SOLDERING PARAMETERS:
Wave solder — 500°F (260°C), 3 seconds Max.
Reflow solder — Not recommended.
2206
000P
Series
14.48
(.57")
4.7 (.184")
0.635
(.025")
38.1
(1.50") TYP.
Axial Lead Material: Tin coated copper.
ORDERING INFORMATION:
Axial Lead
Catalog
Ampere Voltage
Number
Rating Rating
2206
.750P
2206
001P
2206
002P
2206
003P
Nominal
Resistance
Cold Ohms
0.340
0.210
0.0699
0.0505
Nominal
Melting I
2
t
A
2
Sec.
2.95
5.64
30.0
50.0
.750 300
1 300
2 300
3 300
Subminiature Glass Body
Pb
RoHS
PHYSCIALSPECIFICATIONS:
Materials:
Glass Body, Nickel-Plated Brass Fuse Caps
SOLDERING PARAMETERS:
Wave solder- 500F(260C), 3 seconds Max.
Reflow solder- Not recommended
Axial Lead and Cartridge Fuses
The 2AG Fast-Acting fuses are available with axial leads. Axial leaded
fuses are board washable. 2AG fuses provide the same performance
characteristics as their 3AG counterpart, while
occupying one-third the space.
ELECTRICAL CHARACTERISTICS:
% of Ampere
Rating
100%
135%
200%
AGENCY APPROVALS:
All ratings are Listed by UL and Certified by
CSA.
AGENCY FILE NUMBERS:
UL E10480, CSA LR 29862.
INTERRUPTING RATINGS:
0.75–3.0A
10,000 amperes at 125VAC
0.75–3.0A
35 amperes at 250VAC
Opening
Time
4 hours,
Min
imum
1 hour,
Max
imum
1 second,
Max
imum