FEATURES
Universal Thermocouple Compensation:
Internally Provided: Types J, K, T
User Configurable: Types E, R, S, B
Digitally Programmable Type Select
High Accuracy: ±0.8
°
C max over +5
°
C to +45
°
C
High Ambient Rejection: 50 to 1 min.
Low Cost
Small Size: 1.5" X 2" X 0.4"
APPLICATIONS
Thermocouple Signal Conditioning
Temperature Measurement and Control Systems
Temperature Data Acquisition and Logging
Temperature Controllers
1400 Providence Highway, Building #2
Norwood, MA 02062
Phone (781)
551-5500
FAX (781)
551-5555
www.intronicspower.com
GENERAL DESCRIPTION
Model 2B56 is a high accuracy, universal thermocouple cold junction
compensator. Designed to operate with an external temperature sensor
in thermal contact with the cold junction, the 2B56 provides an
automatic compensation for amplified thermocouple signals over wide
ambient temperature variations. The 2B56 is calibrated to compensate
the cold junction to a reference temperature of 0
°
C. The total
compensation error is ±0.8
°
C max over +5
°
C to +45
°
C.
Designed to compensate seven different thermocouple types, the 2B56
may be digitally programmed to select compensation for types J, K
and T, and one user programmed type (E, R, S, B or none). This
feature makes the 2B56 especially suitable for multichannel
applications involving several thermocouple types.
COLD JUNCTION COMPENSATION PRINCIPLES
In thermocouple measurements, temperature is determined by
measuring the potential difference between the measurement (hot)
junction of two dissimilar metals and the reference (cold) junction
which is formed when thermocouple leads are connected to a
measuring circuit. Since this potential difference is proportional to the
temperature difference between the measurement temperature and the
temperature at the reference junction, the reference junction
temperature must be known. Changes in reference junction
temperature influence the output voltage and, therefore, cold junction
compensation is required to eliminate measurement errors.
Two methods may be used to reduce errors introduced at the
thermocouple connections: keep the reference junction at a known
constant temperature, or measure the reference junction temperature
and cancel the changes by the appropriate correction
to the thermocouple output signal. The first method, accomplished by
immersing the reference junction in an ice bath maintained at 0
°
C is
not very practical. The 2B56 employs the second method and has been
specifically designed to eliminate the need for ice baths by
electronically simulating the desired reference point. Digital
programmability, high accuracy and low cost make the 2B56 ideal for
single or multichannel thermocouple temperature measurement,
indication or control systems.
FUNCTIONAL DESCRIPTION
The 2B56 compensates for cold junction temperature by adding a
correction signal at the output of the user's thermocouple amplifier, as
shown in Figure 1. The value of the correction signal is determined by
the cold junction temperature, as measured by a sensor, and the
thermocouple type in use, as specified by two digital TYPE SELECT
inputs. Since compensation is done at the output of the thermocouple
amplifier it is also necessary to scale the correction signal for the gain
of the amplifier. This is done by a scaling circuit which has provision
for a
user-supplied gain-setting resistor for each thermocouple type in
use.
Compensating networks for thermocouple types J, K, and T are
built into the 2B56. A fourth compensation (X) can be
programmed with two external resistors for any other
thermocouple type. The X compensation can also be used without
programming resistors to obtain an uncompensated output when
sensors other than thermocouples are in use.
High Accuracy, Thermocouple
Cold Junction Compensator
Model 2B56
相關PDF資料
PDF描述
2B940A Silicon PNP epitaxial planar type(For power amplification)
2BT-5 THERMOPILE TYPE INFRARED SENSOR
2BZX84C36A surface mount silicon Zener diodes
2BZX84C4V3A surface mount silicon Zener diodes
2BZX84C4V7A surface mount silicon Zener diodes
相關代理商/技術參數
參數描述
2B56A 制造商:Intronics Incorporated 功能描述:SIGNAL CONDITIONING; Signal Conditioner Input:Thermocouple; Signal Conditioner Output:Voltage; No. of Output Channels:4; No. of Channels:4; Type:Digitally Programmable Type Select
2B57A-1 制造商:Intronics Incorporated 功能描述:TEMPERATURE TRANSMITTER; Signal Conditioner Input:Temperature; Signal Conditioner Output:Current; No. of Output Channels:2; No. of Channels:2
2B58 制造商:INTRONICS 制造商全稱:INTRONICS 功能描述:Low Cost Two-Wire Transmitters
2B59 制造商:INTRONICS 制造商全稱:INTRONICS 功能描述:Low Cost Two-Wire Transmitters
2B5UM 功能描述:斷路器 5A MCB B CHAR 277VAC UL508 RoHS:否 制造商:Phoenix Contact 產品:Device Circuit Breakers 產品類型:Thermomagnetic 電流額定值:2 A 電壓額定值 AC:240 V, 277 V 電壓額定值 DC:50 V 極數:1 Pole 執行器類型:Slide 電路功能:Trip Free 系列:CB TM1 工作溫度范圍:- 30 C to + 60 C 照明:No
主站蜘蛛池模板: 广元市| 堆龙德庆县| 土默特左旗| 札达县| 淮阳县| 营山县| 威宁| 六安市| 无为县| 凉城县| 庄河市| 黄浦区| 宁武县| 林周县| 云浮市| 定远县| 精河县| 汝州市| 阿荣旗| 郓城县| 洪洞县| 鹤庆县| 常熟市| 陆丰市| 洛南县| 永清县| 汝阳县| 新郑市| 蕲春县| 噶尔县| 阿拉尔市| 东方市| 开阳县| 长宁县| 康马县| 湾仔区| 马边| 合阳县| 台江县| 郸城县| 伊川县|