Board Mountable
DC-DC Converters
IMP 12 Series
Edition 5/5.2000
1/7
12 Watt DC-DC Converters
IMP 12-Series
Input voltage range 4:1
Input filter built-in
High efficiency up to 82%
Short-circuit proof
No derating
2"
× 2" metal case
Low cost
Summary
The IMP 12 series of primary controlled single transistor
forward DC-DC converters have been developed for
powering commercial type of electronic circuits, e.g. tel-
ephone systems components, industrial controllers and
small appliances. They are suitable for applications with
standard battery voltages. The IMP 12 converters feature
good efficiency and good dynamic response to load
changes and at start-up. The IMP 12 modules are short-cir-
cuit proof.
51
2.0"
51
2.0"
12
0.47"
Type Survey and Key Data
Table 1: Type survey
Output 1
Output 2
Output 3
Output power
Input voltage
Efficiency 1
Type designation
Uo nom
Io nom
Uo nom
Io nom
Uo nom
Io nom
TA = 71°C
Ui min...Ui max
hmin
[V]
[mA]
[V]
[mA]
[V]
[mA]
Po nom [W]
[V DC]
[%]
5
2400
-
12
10...36
77
24 IMP 12-05-7
5
2400
-
18...72
48 IMP 12-05-7
12
1000
-
10...36
24 IMP 12-12-7
12
1000
-
18...72
48 IMP 12-12-7
15
800
-
10...36
24 IMP 12-15-7
15
800
-
18...72
48 IMP 12-15-7
+5
+1200
–5
–1200
-
10...36
24 IMP 12-0505-7
+5
+1200
–5
–1200
-
18...72
48 IMP 12-0505-7
+12
+500
–12
–500
-
10...36
24 IMP 12-1212-7
+12
+500
–12
–500
-
18...72
48 IMP 12-1212-7
+15
+400
–15
–400
-
10...36
24 IMP 12-1515-7
+15
+400
–15
–400
-
18...72
48 IMP 12-1515-7
+5
1500
+12
+200
–12
–200
10...36
24 IMP 12-051212-7
+5
1500
+12
+200
–12
–200
18...72
48 IMP 12-051212-7
+5
1500
+15
+160
–15
–160
10...36
24 IMP 12-051515-7
+5
1500
+15
+160
–15
–160
18...72
48 IMP 12-051515-7
1 Efficiency at
Ui nom and Io nom
Table of Contents
Page
Summary .......................................................................... 1
Type Survey and Key Data .............................................. 1
Type Key .......................................................................... 2
Functional Descripion ....................................................... 2
Electrical Input Data ......................................................... 2
Page
Electrical Output Data ...................................................... 3
Electromagnetic Compatibility (EMC) .............................. 5
Immunity to Environmental Conditions ............................. 5
Mechanical Data .............................................................. 5
Safety and Installation Instructions .................................. 6
Input voltage range up to 72 V DC
1, 2 or 3 outputs up to 30 V DC
1500 V DC I/O electric strength test voltage