Mfg. Co. Inc 240 Stanwell Drive, Concord Ca. 94520 Ph: 925-687-44 Fax: 925-687-3333 www.calex.com
Email: sales@calex.com
eco# 050, 060206-7, 060403-, 090629-2
30 Watt MH/MHW Single Series DC/DC Converters
Features
Up to 30 Watts of Output Power
4: and 2: Input Range
Rated to 00C Case Operating Temperature
24 & 48 Volt Nominal Inputs,
5, 2, 5, and 24 Volt Outputs
Five Year Warranty
Water Washable Design
Positive or Negative Logic
Six Sided Shielding
Output Overvoltage Protection
Selection Chart
Model
Input Range
VDC
Outputs
VDC
Outputs
mA
Min
Max
24S5.6000MH
8
36
5
6000
24S5.6000MHW
9
36
5
6000
24S2.2500MH
8
36
2
2500
24S2.2500MHW
9
36
2
2500
24S5.2000MH
8
36
5
2000
24S5.2000MHW
9
36
5
2000
24S24.250MH
8
36
24
250
24S24.250MHW
9
36
24
250
48S5.6000MH
36
75
5
6000
48S5.6000MHW
8
75
5
6000
48S2.2500MH
36
75
2
2500
48S2.2500MHW
8
75
2
2500
48S5.2000MH
36
75
5
2000
48S5.2000MHW
8
75
5
2000
48S24.250MH
36
75
24
250
48S24.250MHW
8
75
24
250
The Calex MH series are 30 Watt DC/DC converters
in a .6” x 2” case with a 2: and 4: input ratio. The
input voltage range is 8 to 36 or 9 to 36 VDC for 24 Volt
models and 36 to 75 or 8 to 75 for 48 Volt models.
The units are filled with a compound which allows them
to withstand a normal water wash after being soldered to
a PC board.
Description
Default ON/OFF logic is positive. Default case connected to -Vin.
Options:
Add
(-N) to the model number to order negative ON/OFF logic.
(ie. 24S5.600MH-N, 24S5.6000MHW-N)
Add
(-O) to the model number to order case connected to -Vout
(ie. 24S5.6000MH-O, 24S5.6000MHW-O)
Add
(-NO) to the model number to order negative ON/OFF logic and case
connected to -Vout (ie. 24S5.600MH-NO, 24S5.6000MHW-NO)
General Specifications
All Models
Units
Isolation
Isolation Voltage
MIN
544
VDC
Input to Output
Capacitance
TYP
500
pF
ON/OFF Function
Positive Logic
HIGH/OPEN - Module On
LOW - Module Off
Open or > 3VDC
Pulled Low < 0.8 V
Negative Logic
HIGH/OPEN - Module On
LOW - Module Off
Open or > 3 VDC
Pulled Low < 0.8 V
Output Voltage Trim
Trim Range
MIN
MAX
-0
+0
%
Environmental
Case Operating Range
No Derating
MIN
MAX
-40
00
C
Storage Range
MIN
MAX
-55
25
C
Thermal Impedance (6)
TYP
0
C/Watt
General
Unit Weight
TYP
.
oz
Chassis Mounting Kits
MS8
MTBF
> M Hours
Agency Approvals
UL / IEC60950
CSA 22.2 No. 950
CE MARKED
Output Overvoltage
Protection
(OVP) Threshhold
OVP Type - Non-latching
Open Loop Overvoltage
Clamp
MIN
MAX
5
35
%