BCD20007 Rev AA
Page 6 of 14
www.power-one.com
IMX7 DC-DC Series Data Sheet
7-Watt DC-DC Converters
Electrical Output Data
General conditions:
–TA = 25°C, unless TC is specified.
– Pin i connected with Vi –; Trim or R input left open-circuit.
Table 5a: Output data for single-output models
Output
Vo nom
3.3 V
5.1 V
Characteristics
Conditions
min
typ
max
min
typ
max
Unit
Vo
Output voltage setting
Vi nom
3.28
3.32 5.07
5.13
V
Io nom
Output current (nom.)
Vi min – Vi max
1.5
1.2
A
Io L
Current limit 2
Vi nom
3.0
2.4
Vo
Line and load regulation
Vi min – Vi max
±1
%
Io = (0.05 – 1) Io nom
vo
Output voltage noise
Vi min – Vi max
5
70
mVpp
20/40/70IMX7
Io = Io nom
6
20
40
20
40
110IMX7
40
50
40
50
Vo clp
Output overvoltage limit 7
Minimum load 1%
115
130
115
130
%
Co ext
Admissiblecapacitive load
2500
2000
mF
Vo d
Dynamic
Voltage deviat.
Vi nom
±250
mV
td
load
Recovery time
Io nom
1/2 Io nom
11
ms
regulation
αVo
Temperature coefficient
Vi min – Vi max
±0.02
%/K
Vo/TC (TC min to TC max)
Io = (0.05 – 1) Io nom
Table 5b: Output data for double-output models
Output
Vo nom
2 × 5 V
2 × 12 V
2 ×15 V
2 × 24 V
Characteristics
Conditions
min
typ
max
min
typ
max
min
typ
max
min
typ
max
Unit
Vo1
Output voltage setting
Vi nom
4.96
5.04 11.90
12.10 14.88
15.12 23.81
24.19 VDC
Vo2
Io1 = Io2 = 0.5 Io nom 4.95
5.05 11.88
12.12 14.85
15.15 23.75
24.25
Io nom
Output
20IMX7 Vi min – Vi max
2 × 0.6
2 × 0.25
2 × 0.2
2 × 0.13
A
current 1
40/70/110IMX7
2 × 0.7
2 × 0.3
2 × 0.24
2 × 0.15
Io L
Current
20IMX7 Vi nom
2.4
1.0
0.95
0.5
limit 2 3
40/70/110IMX7
2.8
1.2
1.1
0.6
Vo1
Line regulation
Vi min – Vi max, Io nom
±1
%
Vo l
Load regulation 4
Vi nom , (0.1 – 1) Io nom
±3
vo1, 2
Output voltage noise
Vi min – Vi ma
5
80
120
150
240
mVpp
Io = Io nom
6
20
40
25
50
30
60
50
100
Vo clp
Output overvoltage limit 7
Minimum load 1%
115
130
115
130
115
130
115
130
%
Co ext
Admissible capacitive load 3
2000
300
200
100
F
Vo d
Dynamic
Voltage deviat. Vi nom
±150
±330
±350
±600
mV
td
load
Recovery time
Io nom
1/2 Io nom
11
1
ms
regulation
αVo
Temperature coefficient
Vi min – Vi max
±0.02
%/K
Vo/TC (TC min to TC max)
Io = (0.05 – 1) Io nom
1 Each output is capable of delivering full output power Po nom according to table: Model Selection.
2 The current limit is primary side controlled.
3 Measured with both outputs connected in parallel.
4 Conditions for specified output. Other output loaded with constant current Io = 0.5 Io nom.
5 BW = 20 MHz
6 Measured with a probe according to EN 61204.
7 The overvoltage protection is not tracking with the R control.