2008–2011 Teridian Semiconductor Corporation
27
2.3.6
Pulse Generators
The 71M6541D/F and 71M6542F provide four pulse generators, VPULSE, WPULSE, XPULSE and YPULSE,
as well as hardware support for the VPULSE and WPULSE pulse generators. The pulse generators can
be used to output CE status indicators, SAG for example, to DIO pins. All pulses can be configured to
generate interrupts to the MPU.
The polarity of the pulses may be inverted with control bit PLS_INV (I/O RAM 0x210C[0]). When this bit is
set, the pulses are active high, rather than the more usual active low. PLS_INV inverts all the pulse outputs.
The function of each pulse generator is determined by the CE code and the MPU code must configure the
corresponding pulse outputs in agreement with the CE code. For example, standard CE code produces a
mains zero-crossing pulse on XPULSE and a SAG pulse on YPULSE.
A common use of the zero-crossing pulses is to generate interrupt in order to drive real-time clock software
in places where the mains frequency is sufficiently accurate to do so and also to adjust for crystal aging.
A common use for the SAG pulse is to generate an interrupt that alerts the MPU when mains power is about
to fail, so that the MPU code can store accumulated energy and other data to EEPROM before the
V3P3SYS supply voltage actually drops.
2.3.6.1 XPULSE and YPULSE
Pulses generated by the CE may be exported to the XPULSE and YPULSE pulse output pins. Pins
SEGDIO6 and SEGDIO7 are used for these pulses, respectively. Generally, the XPULSE and YPULSE
outputs can be updated once on each pass of the CE code.
See 5.3 CE Interface Description on page 125 for details.
2.3.6.2 VPULSE and WPULSE
Referring to Figure 12, during each CE code pass the hardware stores exported WPULSE and VPULSE sign
bits in an 8-bit FIFO and outputs them at a specified interval. This permits the CE code to calculate the
VPULSE and WPULSE outputs at the beginning of its code pass and to rely on hardware to spread them
over the multiplexer frame. As seen in Figure 12, the FIFO is reset at the beginning of each multiplexer
frame. As also seen in Figure 12, the I/O RAM register PLS_INTERVAL[7:0] (I/O RAM 0x210B[7:0])
controls the delay to the first pulse update and the interval between subsequent updates. The LSB of
the PLS_INTERVAL[7:0] register is equivalent to 4 CK_FIR cycles (CK_FIR is typically 4.9152MHz if
PLL_FAST=1 and ADC_DIV=0, but other CK_FIR frequencies are possible; see the ADC_DIV definition in
Table 76.) If PLS_INTERVAL[7:0]=0, the FIFO is deactivated and the pulse outputs are updated immediately.
The MUX frame duration in units of CK_FIR clock cycles is given by:
If PLL_FAST=1:
MUX frame duration in CK_FIR cycles = [1 + (
FIR_LEN+1) * (ADC_DIV+1) * (MUX_DIV)] * [150 / (ADC_DIV+1)]
If PLL_FAST=0:
MUX frame duration in CK_FIR cycles = [3 + 3*(
FIR_LEN+1) * (ADC_DIV+1) * (MUX_DIV)] * [48 / (ADC_DIV+1)]
PLS_INTERVAL[7:0] in units of CK_FIR clock cycles is calculated by:
PLS_INTERVAL[7:0] = floor (Mux frame duration in CK_FIR cycles / CE pulse updates per Mux frame / 4 )
Since the FIFO resets at the beginning of each multiplexer frame, the user must specify
PLS_INTERVAL[7:0] so that all of the possible pulse updates occurring in one CE execution are output
before the multiplexer frame completes. For instance, the 71M654x CE code outputs six updates per
multiplexer interval, and if the multiplexer interval is 1950 CK_FIR clock cycles long, the ideal value for
the interval is 1950/6/4 = 81.25. However, if PLS_INTERVAL[7:0] = 82, the sixth output occurs too late and
would be lost. In this case, the proper value for PLS_INTERVAL[7:0] is 81 (i.e., round down the result).
Since one LSB of
PLS_INTERVAL[7:0] is equal to 4 CK_FIR clock cycles, the pulse time interval TI in units of
CK_FIR clock cycles is:
TI = 4*PLS_INTERVAL[7:0]
相關PDF資料
PDF描述
71M6541D-IGTR/F SPECIALTY ANALOG CIRCUIT, PQFP64
71M6542F-IGTR/F SPECIALTY ANALOG CIRCUIT, PQFP100
71M6541D-IGT/F SPECIALTY ANALOG CIRCUIT, PQFP64
71M6542G-IGT/F SPECIALTY ANALOG CIRCUIT, PQFP100
71M6541G-IGT/F SPECIALTY ANALOG CIRCUIT, PQFP64
相關代理商/技術參數
參數描述
71M6541FT-IGT/F 制造商:Maxim Integrated Products 功能描述:1-PHASE SOC, 64KB FLASH, PRES TEMP SENSOR - Rail/Tube
71M6541FT-IGTR/F 制造商:Maxim Integrated Products 功能描述:1-PHASE SOC, 64KB FLASH, PRES TEMP SENSOR - Tape and Reel
71M6541G 制造商:未知廠家 制造商全稱:未知廠家 功能描述:71M6541D/71M6541F/71M6541G/71M6542F/71M6542G 是 TeridianTM 的第4 代高集成度單相電表SoC
71M6541G-IGT/F 功能描述:計量片上系統 - SoC 71M6541G-IGT/F RoHS:否 制造商:Maxim Integrated 核心:80515 MPU 處理器系列:71M6511 類型:Metering SoC 最大時鐘頻率:70 Hz 程序存儲器大小:64 KB 數據 RAM 大小:7 KB 接口類型:UART 可編程輸入/輸出端數量:12 片上 ADC: 安裝風格:SMD/SMT 封裝 / 箱體:LQFP-64 封裝:Reel
71M6541GT-IGT/F 功能描述:IC ENERGY METER 64-LQFP 制造商:maxim integrated 系列:Single Converter Technology? 包裝:托盤 零件狀態:停產 輸入阻抗:- 測量誤差:0.1% 電壓 - I/O 高:2V 電壓 - I/O 低:0.8V 電流 - 電源:- 電壓 - 電源:3 V ~ 3.6 V 表計類型:單相 工作溫度:-40°C ~ 85°C 安裝類型:表面貼裝 封裝/外殼:64-LQFP 供應商器件封裝:64-LQFP(10x10) 標準包裝:1,000
主站蜘蛛池模板: 井研县| 隆安县| 绥德县| 开化县| 改则县| 花莲县| 韩城市| 山丹县| 永兴县| 略阳县| 安宁市| 原阳县| 柯坪县| 沂水县| 紫阳县| 临安市| 图木舒克市| 清河县| 建宁县| 甘孜| 二连浩特市| 拉萨市| 营口市| 清流县| 武平县| 北票市| 邯郸市| 综艺| 化德县| 沙田区| 越西县| 张北县| 乐至县| 金华市| 温州市| 盐源县| 德兴市| 吐鲁番市| 怀集县| 临泉县| 酉阳|