ANODE CONNECTION FITTED
WITH 8-32 UNC SCREW
A
C
1
B
E
D
MOUNTING FLANGE
SEE NOTE 1
F
SEE NOTE 2
SEE NOTE 3
1
G
RESERVOIR HEATER LEAD (RED)
L LONG, TAG TO FIT
1
M TERMINAL
GRID LEAD (GREEN) L LONG
TAG TO FIT
1
M TERMINAL
CATHODE HEATER LEAD (YELLOW)
L LONG, TAG TO FIT
1
M TERMINAL
4 HOLES
1
H
EQUISPACED
ON J PCD
1
K
5027C
OUTLINE
(All dimensions without limits are nominal)
Ref
Millimetres
Inches
A
B
C
D
E
F
G
H
J
K
L
M
61.90
+
1.52
34.93
+
0.25
49.20
+
1.52
7.09 max
0.81
25.4 max
38.1 max
4.19
51.6
57.15 max
152.4
5.16
2.437
+
0.060
1.375
+
0.010
1.937
+
0.060
0.279 max
0.032
1.000 max
1.500 max
0.165
2.031
2.250 max
6.000
0.203
Inch dimensions have been derived from millimetres.
Outline Notes
1. The mounting flange is the connection for the
cathode, cathode heater return and reservoir
heater return.
2. A minimum clearance of 25.4 mm (1.000 inch)
must be allowed below the mounting flange.
3. Where e2v technologies gives prior agreement
to the use of alternative lead/mounting ar-
rangements on these posts, great care must be
taken to avoid damaging the threads and the
metal/ceramic joints. A flat wrench must be
used to hold the nut nearest the ceramic while
a torque wrench, set to a value of less than
0.046 kg-m (4 lb-in), is used on the other nut.
Printed in England
#
e2v technologies
7665A, page 3
Whilst e2v technologies has taken care to ensure the accuracy of the information contained herein it accepts no responsibility for the consequences of any use
thereof and also reserves the right to change the specification of goods without notice. e2v technologies accepts no liability beyond that set out in its standard
conditions of sale in respect of infringement of third party patents arising from the use of tubes or other devices in accordance with information contained herein.