欧美成人免费电影,国产欧美一区二区三区精品酒店,精品国产a毛片,色网在线免费观看

參數(shù)資料
型號: AD7751AARS
廠商: ANALOG DEVICES INC
元件分類: 模擬信號調(diào)理
英文描述: Energy Metering IC With On-Chip Fault Detection
中文描述: SPECIALTY ANALOG CIRCUIT, PDSO24
封裝: SSOP-24
文件頁數(shù): 13/16頁
文件大小: 249K
代理商: AD7751AARS
REV. A
–13–
AD7751
FREQUENCY
Hz
40
P
0.05
0.10
0
0.05
0.10
0.15
0.20
0.25
0.30
45
50
55
60
65
70
Figure 11. Phase Error Between Channels (40 Hz to 70 Hz)
DIGITAL-TO-FREQUENCY CONVERSION
As previously described, the digital output of the low-pass filter
after multiplication contains the real-power information. However,
since this LPF is not an ideal “brick wall” filter implementation,
the output signal also contains attenuated components at
the line frequency and its harmonics, i.e., cos(h
ω
t) where
h = 1, 2, 3, . . . etc.
The magnitude response of the filter is given by:
1
1
| ( )|
H f
( /8 9
f
)
Hz
=
+
(6)
For a line frequency of 50 Hz, this would give an attenuation of
the 2
ω
(100 Hz) component of approximately –22 dBs. The
dominating harmonic will be at twice the line frequency, i.e.,
cos(2
ω
t) and this is due to the instantaneous power signal.
Figure 12 shows the instantaneous real-power signal output of
LPF which still contains a significant amount of instantaneous
power information, i.e., cos(2
ω
t). This signal is then passed to
the digital-to-frequency converter where it is integrated (accumu-
lated) over time in order to produce an output frequency. This
accumulation of the signal will suppress or average out any non-
dc components in the instantaneous real-power signal. The average
value of a sinusoidal signal is zero. Hence the frequency generated
by the AD7751 is proportional to the average real power. Figure
12 shows the digital-to-frequency conversion for steady load
conditions, i.e., constant voltage and current.
As can be seen in the diagram, the frequency output CF is seen
to vary over time, even under steady load conditions. This fre-
quency variation is primarily due to the cos(2
ω
t) component in
the instantaneous real-power signal. The output frequency on CF
can be up to 128 times higher than the frequency on F1 and F2.
This higher output frequency is generated by accumulating the
instantaneous real-power signal over a much shorter time while
converting it to a frequency. This shorter accumulation period
means less averaging of the cos(2
ω
t) component. As a conse-
quence, some of this instantaneous power signal passes through
the digital-to-frequency conversion. This will not be a problem
in the application. Where CF is used for calibration purposes,
the frequency should be averaged by the frequency counter.
This will remove any ripple. If CF is being used to measure energy,
e.g., in a microprocessor-based application, the CF output should
also be averaged to calculate power. However, if an energy
measurement is being made by counting pulses, no averaging is
required. Because the outputs F1 and F2 operate at a much
lower frequency, a lot more averaging of the instantaneous real-
power signal is carried out. The result is a greatly attenuated
sinusoidal content and a virtually ripple-free frequency output.
2
V I
2
FREQUENCY
RAD/S
LPF
DIGITAL-TO-
FREQUENCY
F1
F2
DIGITAL-TO-
FREQUENCY
CF
INSTANTANEOUS REAL-POWER SIGNAL
(FREQUENCY DOMAIN)
MULTIPLIER
TIME
FF1
FCF
TIME
V
I
0
LPF TO EXTRACT
REAL POWER
(DC TERM)
cos(2 t)
ATTENUATED BY LPF
Figure 12. Real-Power-to-Frequency Conversion
FAULT DETECTION
The AD7751 incorporates a novel fault detection scheme that
warns of fault conditions and allows the AD7751 to continue
accurate billing during a fault event. The fault detection function is
designed to work over a line frequency of 45 Hz to 55 Hz. The
AD7751 does this by continuously monitoring both the phase
and neutral (return) currents. A fault is indicated when these
currents differ by more than 12.5%. However, even during a
fault the output pulse rate on F1 and F2 is generated using the
larger of the two currents. Because the AD7751 looks for a
difference between the signals on V1A and V1B, it is important
that both current transducers are closely matched.
On power-up the output pulse rate of the AD7751 is proportional
to the product of the signals on Channel V1A and Channel 2. If
there is a difference of greater than 12.5% between V1A and
V1B on power-up, the fault indicator (FAULT) will go active
after about one second. In addition, if V1B is greater than V1A
the AD7751 will select V1B as the input. The fault detection is
automatically disabled when the voltage signal on Channel 1 is less
than 0.5% of the full-scale input range. This will eliminate false
detection of a fault due to noise at light loads.
相關(guān)PDF資料
PDF描述
AD7755AAN-REF GT 7C 7#8 SKT RECP
AD7755AARS Energy Metering IC with Pulse Output
AD7755ABRS Energy Metering IC with Pulse Output
AD7755AAN Energy Metering IC with Pulse Output
AD7760 2.5 MSPS, 20-Bit ADC
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
AD7751ABRS 制造商:AD 制造商全稱:Analog Devices 功能描述:Energy Metering IC With On-Chip Fault Detection
AD7751AN 制造商:Rochester Electronics LLC 功能描述:PRODUCT TO FREQUENCY CONV - Bulk
AD7751ARS 制造商:Rochester Electronics LLC 功能描述:- Bulk 制造商:Analog Devices 功能描述:
AD7751BRS 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Power Metering
AD77537JP 制造商:Rochester Electronics LLC 功能描述:- Bulk
主站蜘蛛池模板: 莱阳市| 土默特右旗| 桦南县| 四平市| 绵阳市| 岫岩| 集贤县| 平顶山市| 连平县| 广汉市| 宜兰县| 长葛市| 阿拉善右旗| 甘肃省| 大庆市| 武威市| 习水县| 三亚市| 宁夏| 佛坪县| 山阴县| 南康市| 合阳县| 潼关县| 高碑店市| 新乡市| 建水县| 南部县| 楚雄市| 林口县| 蓬莱市| 涞源县| 田东县| 夏河县| 松原市| 赣榆县| 同江市| 翁源县| 汝阳县| 九台市| 罗城|