AD8314
–10–
REV. 0
INPUT AMPLITUDE – dBV
1.2
0–70
0
–60
(–47dBm)
V
U
–50
–40
–30
–20
–10
(+3dBm)
1.0
0.8
0.6
0.4
0.2
V
S
= 3V
R
T
= 52.3
V
3
–3
2
1
0
–1
–2
6
1dB DYNAMIC RANGE
E
6
3dB DYNAMIC RANGE
INTERCEPT
Figure 29. V
UP
and Log Conformance Error vs. Input
Level vs. Input Level at 900 MHz
Transfer Function in Terms of Slope and Intercept
The transfer function of the AD8314 is characterized in terms of
its Slope and Intercept. The logarithmic slope is defined as the
change in the RSSI output voltage for a 1 dB change at the input.
For the AD8314, slope is nominally 21.5 mV/dB. So a 10 dB
change at the input results in a change at the output of approxi-
mately 215 mV. The plot of Log-Conformance (Figure 29) shows
the range over which the device maintains its constant slope. The
dynamic range can be defined as the range over which the error
remains within a certain band, usually
±
1 dB or
±
3 dB. In
Figure 29, for example, the
±
1 dB dynamic range is approxi-
mately 50 dB (from –13 dBV to –63 dBV).
The intercept is the point at which the extrapolated linear
response would intersect the horizontal axis (Figure 29). Using
the slope and intercept, the output voltage can be calculated for
any input level within the specified input range using the equation:
V
UP
= V
SLOPE
×
(
P
IN
– P
O
)
where
V
UP
is the demodulated and filtered RSSI output,
V
SLOPE
is the logarithmic slope, expressed in V/dB,
P
IN
is the input sig-
nal, expressed in decibels relative to some reference level (either
dBm or dBV in this case) and
P
O
is the logarithmic intercept,
expressed in decibels relative to the same reference level.
For example, at an input level of –40 dBV (–27 dBm), the
output voltage will be
V
OUT
= 0.020
V/dB
×
(–40
dBV
– (–63
dBV
)) = 0.46
V
dBV vs. dBm
The most widely used convention in RF systems is to specify power
in dBm, that is, decibels above 1 mW in 50
. Specification of
log amp input levels in terms of power is strictly a concession to
popular
convention; they do
not
respond to power (tacitly “power
absorbed at the input”), but to the input voltage. The use of dBV,
defined as
decibels with respect to a 1 V rms sine wave
, is more pre-
cise, although this is still not unambiguous because waveform is
also involved in the response of a log amp, which, for a complex
input (such as a CDMA signal), will not follow the rms value
exactly. Since most users specify RF signals in terms of power—
more specifically, in dBm/50
—we use both dBV and dBm in
specifying the performance of the AD8314, showing equivalent
dBm levels for the special case of a 50
environment. Values in
dBV are converted to dBm re 50
by adding 13.
Filter Capacitor
The video bandwidth of both V_UP and V_DN is approximately
3.5 MHz. In CW applications where the input frequency is much
higher than this, no further filtering of the demodulated signal
will be required. Where there is a low-frequency modulation of
the carrier amplitude, however, the low-pass corner must be
reduced by the addition of an external filter capacitor, C
F
(see
Figure 28). The video bandwidth is related to C
F
by the equation
Video Bandwidth
k
pF
C
F
=
×
×
+
1
2
4 4
.
10
(
π
)
Operating in Controller Mode
Figure 30 shows the basic connections for operation in the con-
troller mode and Figure 31 shows a block diagram of a typical
controller mode application. The feedback from V_UP to VSET is
broken and the desired setpoint voltage is applied to VSET from
the controlling source (often this will be a DAC). V
DN
will rail
high (2.2 V on a 3.3 V supply, 1.9 V on a 2.7 V supply) when
the applied power is less than the value corresponding to the set-
point voltage. When the input power slightly exceeds this value,
V
DN
would, in the absence of the loop via the power amplifier
gain pin, decrease rapidly toward ground. In the closed loop,
however, the reduction in V
DN
causes the power amplifier to re-
duce its output. This restores a balance between the actual power
level sensed at the input of the AD8314 and the demanded value
determined by the setpoint. This assumes that the gain control
sense of the variable gain element is positive, that is, an increas-
ing voltage from V_DN will tend to increase gain. The output
swing and current sourcing capability of V_DN are shown in
Figures 19 and 20.
1
2
3
4
ENBL
RFIN
AD8314
8
7
6
5
VSET
FLTR
V DN
VPOS
COMM
V UP
V
S
VDN
V
S
INPUT
VSET
C
F
0.1
m
F
52.3
V
Figure 30. Basic Connections for Operation in Controller
Mode
DAC
FLTR
V UP
VSET
AD8314
DIRECTIONAL
COUPLER
POWER
AMPLIFIER
RF INPUT
GAIN
CONTROL
VOLTAGE
RFIN
V DN
C
F
52.3
V
Figure 31. Typical Controller Mode Application
相關PDF資料
PDF描述
AD8316 Dual Output GSM PA Controller
AD8316-EVAL Dual Output GSM PA Controller
AD8316ACP-EVAL Dual Output GSM PA Controller
AD8316ACP-REEL Dual Output GSM PA Controller
AD8316ACP-REEL7 Dual Output GSM PA Controller
相關代理商/技術參數
參數描述
AD8315 制造商:AD 制造商全稱:Analog Devices 功能描述:50 dB GSM PA Controller
AD8315_06 制造商:AD 制造商全稱:Analog Devices 功能描述:50 dB GSM PA Controller
AD8315ACHIPS 制造商:AD 制造商全稱:Analog Devices 功能描述:50 dB GSM PA Controller
AD8315ACP-EVAL 制造商:Analog Devices 功能描述:EVAL BOARD GSM PA CONTR AD8
AD8315ACP-REEL 制造商:Analog Devices 功能描述:
主站蜘蛛池模板: 重庆市| 奉新县| 铜鼓县| 高密市| 裕民县| 栾城县| 安多县| 湘阴县| 扬州市| 墨江| 仙桃市| 随州市| 莎车县| 泰和县| 皋兰县| 灌南县| 子洲县| 广饶县| 色达县| 昔阳县| 光泽县| 威远县| 越西县| 泸定县| 郁南县| 民勤县| 汉沽区| 新平| 报价| 奇台县| 张掖市| 广安市| 修文县| 岳阳市| 乳山市| 宿州市| 南宫市| 富宁县| 蓬莱市| 凤冈县| 宁海县|