–18–
FREQUENCY – Hz
30
d
20
–20
110
5
10
0
–10
110
6
110
7
Figure 39. Change in ADDC02808PB Differential Emis-
sions vs. ADDC02805SA Emissions with the Same Test
Setup
dB, by which the differential emissions would change if either of
these approaches were followed. Notice that the inductor solu-
tion provides substantial attenuation in the 1 MHz and higher
frequency range, while the larger capacitor solution has a more
uniform effect. These proposed solutions are suggestions; they
have not been tested.
FREQUENCY – Hz
30
d
20
–20
110
5
10
0
–10
110
6
110
7
Figure 40. Change in ADDC02808PB Differential Emissions
vs. the ADDC02805SA Emissions with External 30
μ
F
Capacitor
FREQUENCY – Hz
30
d
20
–20
110
5
10
0
–10
110
6
110
7
Figure 41. Change in ADDC02808PB Differential Emissions
vs. the ADDC02805SA Emissions with External 0.5
μ
H,
16 A Inductor
The peak in the radiated emissions in the 20 MHz–30 MHz
range of Figure 14 is dominated by common-mode noise. This
common-mode noise emission is changed only slightly between
the ADDC02808PB and the ADDC02805SA converters since it
does not depend on the power level or the differential input
filter. The turns ratio on the transformer has been changed, so
we expect the common-mode emissions might be 2–4 times
larger. This increase could be countered by increasing the 82 nF
common-mode capacitors of Figure 15 correspondingly. Again,
this solution is a suggestion; it has not been tested.
Finally, the pulsed nature of the load means there will be a
substantial ripple in the input current at the fundamental pulse
rate and its harmonics. This ripple can be calculated once the
power is known as a function of time by dividing by the input
voltage. For instance, if the load switches between zero and
200 W (260 W at the input) at 1 kHz with a duty ratio of 50%,
the current drawn by the converter will have a 9.3 A on, 0 A off,
50% duty ratio input current waveform (260 W/28 V = 9.3 A).
This waveform has an average of 4.65 A and a square wave of
plus and minus 4.65 A around this average. This square wave of
current has a fundamental component as well as odd harmonics
(3rd, 5th, 7th, . . .). The peak of the fundamental component is
(4/
π
) 4.65. The rms value of this component is .707 times the
peak, or 4.2 A.
With the test setup in Figure 15, given the impedances of the
LISNs and the 100
μ
F capacitor with its 1
series resistance, a
3.6 V rms waveform would result from this fundamental
component of the input current. The MIL-STD-461D limit
shown in Figure 11 calls for approximately 100 mV at the 1 kHz
frequency. If this limit is to be met, substantial filtering at the
lower frequencies will have to be added to the system.
RELIABILITY CONSIDERATIONS
MTBF (Mean Time Between Failure) is a commonly used
reliability concept that applies to repairable items in which
failed elements are replaced upon failure. The expression for
MTBF is
MTBF = T/r
where
T
= total operating time
r
= number of failures
In lieu of actual field data, MTBF can be predicted per
MIL-HDBK-217.
MTBF, Failure Rate, and Probability of Failure:
A proper
understanding of MTBF begins with its relationship to lambda
(
λ
), which is the failure rate. If a constant failure rate is assumed,
then MTBF = 1/
λ
, or
λ
= 1/MTBF. If a power supply has an
MTBF of 1,000,000 hours, this does not mean it will last
1,000,000 hours before it fails. Instead, the MTBF describes
the failure rate. For 1,000,000 hours MTBF, the failure rate
during any hour is 1/1,000,000, or 0.0001%. Thus, a power
supply with an MTBF of 500,000 hours would have twice the
failure rate (0.0002%) of one with 1,000,000 hours.
What users should be interested in is the probability of a power
supply not failing prior to some time t. Given the assumption of
a constant failure rate, this probability is defined as
R
(
t
)
=
e
λ
t
相關PDF資料
PDF描述
ADDC02815 28 V/100 W DC/DC Converters(帶積分EMI濾波器的DC-DC轉換器)
ADDC02812 28 V/100 W DC/DC Converters(帶積分EMI濾波器的DC-DC轉換器)
ADDC02828SA 28 V/100 W DC/DC Converter with Integral EMI Filter
ADDC02828SATV 28 V/100 W DC/DC Converter with Integral EMI Filter
ADDC02828SAKV JT 7C 7#20 PIN GRND PLUG
相關代理商/技術參數
參數描述
ADDC02808PBTV/883B 制造商:未知廠家 制造商全稱:未知廠家 功能描述:DC-to-DC Voltage Converter
ADDC02808PBTV/QMLH 制造商:AD 制造商全稱:Analog Devices 功能描述:28 V, 200 W Pulsed DC/DC Converter with Integral EMI Filter
ADDC02812DA 制造商:AD 制造商全稱:Analog Devices 功能描述:28 V/100 W DC/DC Converters with Integral EMI Filter
ADDC02812DAKV 制造商:AD 制造商全稱:Analog Devices 功能描述:28 V/100 W DC/DC Converters with Integral EMI Filter
ADDC02812DATV 制造商:AD 制造商全稱:Analog Devices 功能描述:28 V/100 W DC/DC Converters with Integral EMI Filter
主站蜘蛛池模板: 辽宁省| 安福县| 合阳县| 佛冈县| 东乌| 定结县| 石门县| 会理县| 高州市| 二连浩特市| 巴青县| 通渭县| 郸城县| 勃利县| 牡丹江市| 陆丰市| 江都市| 铁力市| 乳山市| 同仁县| 许昌市| 金溪县| 吉水县| 九龙县| 霍州市| 阳新县| 烟台市| 鹤岗市| 吉木萨尔县| 大化| 麟游县| 体育| 贵港市| 黄石市| 五家渠市| 海门市| 榆中县| 长海县| 辽阳县| 临西县| 辽宁省|