SELECTING A FREQUENCY FOR AN ENERGY METER APPLICATION
As shown in Table 5, the user can select one of seven
frequencies. This frequency selection determines the maximum
frequency on F1 and F2. These outputs are intended to be used
to drive the energy register (electromechanical or other). Since
seven different output frequencies can be selected, the available
frequency selection has been optimized for a 3-phase 4-wire
service with a meter constant of 100 imp/kWhr and a
maximum current of between 10 A and 100 A. Table 8 shows
the output frequency for several maximum currents (I
MAX
) with
a line voltage of 220 V (phase neutral). In all cases, the meter
constant is 100 imp/kWhr.
Table 8. F1 and F2 Frequency at 100 imp/kWhr
I
MAX
(A)
F1 and F2 (Hz)
10
0.18
25
0.46
40
0.73
60
1.10
80
1.47
100
1.83
Rev. PrA | Page 24 of 27
The F
1–7
frequencies allow complete coverage of this range of
output frequencies on F1 and F2. When designing an energy
meter, the nominal design voltage on the voltage channels
should be set to half scale to allow for calibration of the meter
constant. The current channel should also be no more than half
scale when the meter sees maximum load. This allows
overcurrent signals and signals with high crest factors to be
accommodated. Table 9 shows the output frequency on F1 and
F2 when all six analog inputs are half scale.
Table 9. F1 and F2 Frequency with Half-Scale AC Inputs
SCF
S1
S0
F
1–7
(Hz)
(Half-Scale AC Inputs) (Hz)
0
0
0
2.3
0.23
1
0
0
4.61
0.46
0
0
1
1.15
0.12
1
0
1
4.61
0.46
0
1
0
5.22
0.53
1
1
0
1.15
0.12
0
1
1
0.58
0.06
1
1
1
0.58
0.06
Frequency on F1 and F2
When selecting a suitable F
1–7
frequency for a meter design, the
frequency output at I
MAX
(maximum load) with a 100 imp/kWhr
meter constant should be compared with Column 5 of Table 9. The
frequency that is closest in Table 9 determines the best choice of
frequency (F
1–7
). For example, if a 3-phase 4-wire Wye meter with a
25 A maximum current is being designed, the output frequency on
F1 and F2 with a 100 imp/kWhr meter constant is 0.46 Hz at 25 A
and 220 V (see Table 8). Looking at Table 9, the closest frequency to
0.46 Hz in Column 5 is 0.53 Hz. Therefore, F
1–7
= 5.22 Hz is
selected for this design.
FREQUENCY OUTPUTS
Figure 2 shows a timing diagram for the various frequency
outputs. The outputs F1 and F2 are the low frequency outputs
that can be used to directly drive a stepper motor or electro-
mechanical impulse counter. The F1 and F2 outputs provide
two alternating high going pulses. The pulse width (t
1
) is set at
120 ms, and the time between the rising edges of F1 and F2 (t
3
)
is approximately half the period of F1 (t
2
). If, however, the
period of F1 and F2 falls below 550 ms (1.81 Hz), the pulse
width of F1 and F2 is set to half of their period. The maximum
output frequencies for F1 and F2 are shown in Table 6.
The high frequency CF output is intended to be used for
communications and calibration purposes. CF produces a 90 ms-
wide active high pulse (t
4
) at a frequency proportional to active
power. The CF output frequencies are given in Table 7. As in the
case of F1 and F2, if the period of CF (t
5
) falls below 190 ms, the CF
pulse width is set to half the period. For example, if the CF
frequency is 20 Hz, the CF pulse width is 25 ms.
NO LOAD THRESHOLD
The ADE7752B includes no load threshold and start-up current
circuitry features that eliminate any creep effects in the meter.
The circuit is designed to issue a minimum output frequency.
Any load generating a frequency lower than this minimum
output frequency does not cause a pulse to be issued on F1, F2, or
CF. The no-load threshold is determined by the sum of all phases.
The minimum output frequency is given as 0.0075% of the full-
scale output frequency for each of the F
1–7
frequency selections,
or
approximately 0.0029% of the F
1–7
frequency (see Table 10). For
example, for an energy meter with a 100 imp/kWhr meter
constant using F
1–7
(4.61 Hz), the minimum output frequency at
F1 or F2 would be
13.35 × 10
–5
Hz. This would be 2.13 × 10
–3
Hz
at CF (16 × F1 Hz). In this example, the no load threshold would
be equivalent to 4.8 W of load or a start-up current of 20.03 mA
at 240 V
相關PDF資料
PDF描述
ADE7753 Active and Apparent Energy Metering IC with di/dt sensor interface
ADE7753ARS Active and Apparent Energy Metering IC with di/dt sensor interface
ADE7753ARSRL Active and Apparent Energy Metering IC with di/dt sensor interface
ADE7754 ADE7754
ADE7754AR ADE7754
相關代理商/技術參數
參數描述
ADE7753 制造商:AD 制造商全稱:Analog Devices 功能描述:Active and Apparent Energy Metering IC with di/dt sensor interface
ADE7753_10 制造商:AD 制造商全稱:Analog Devices 功能描述:Single-Phase Multifunction Metering IC with di/dt Sensor Interface
ADE7753ARS 制造商:Analog Devices 功能描述:Single Phase Multifunction Metering IC 20-Pin SSOP 制造商:Rochester Electronics LLC 功能描述:- Bulk 制造商:Analog Devices 功能描述:IC SEMICONDUTOR ((NS))
ADE7753ARSRL 制造商:Analog Devices 功能描述:Single Phase Multifunction Metering IC 20-Pin SSOP T/R 制造商:Rochester Electronics LLC 功能描述:- Bulk
ADE7753ARSZ 功能描述:IC ENERGY METERING 1PHASE 20SSOP RoHS:是 類別:集成電路 (IC) >> PMIC - 能量測量 系列:- 產品培訓模塊:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 標準包裝:2,500 系列:*
主站蜘蛛池模板: 呼和浩特市| 虞城县| 秭归县| 内黄县| 南雄市| 乌什县| 东乌| 德令哈市| 元阳县| 雷州市| 呼图壁县| 子洲县| 成武县| 历史| 雷波县| 绥芬河市| 积石山| 武宣县| 阿克| 安庆市| 石渠县| 延庆县| 尚志市| 百色市| 陇西县| 大庆市| 嘉鱼县| 乌兰县| 麻栗坡县| 万荣县| 历史| 长治县| 武邑县| 侯马市| 鹤庆县| 夏邑县| 甘孜县| 确山县| 二连浩特市| 万宁市| 巢湖市|