Preliminary Technical Data
ADE7752B
TERMINOLOGY
Measurement Error
The error associated with the energy measurement made by the
ADE7752B is defined by the following formula:
Rev. PrA | Page 11 of 27
%
100
Energy
True
Energy
True
7762
ADE
by
Registered
Energy
Error
Percentage
×
=
Error between Channels
The high-pass filter (HPF) in the current channel has a phase
lead response. To offset this phase response and equalize the
phase response between channels, a phase correction network is
placed in the current channel. The phase correction network
ensures a phase match between the current channels and
voltage channels to within ±0.1° over a range of 45 Hz to 65 Hz
and ±0.2° over a range of 40 Hz to 1 kHz (see Figure 25 and
Figure 26).
Power Supply Rejection (PSR)
This quantifies the ADE7752B measurement error as a
percentage of reading when the power supplies are varied.
For the ac PSR measurement, a reading at a nominal supply
(5 V) is taken. A 200 mV rms/100 Hz signal is then introduced
onto the supply and a second reading is obtained under the
same input signal levels. Any error introduced is expressed as a
percentage of reading. See definition for Measurement Error.
For the dc PSR measurement, a reading at nominal supplies
(5 V) is taken. The supply is then varied ±5% and a second
reading is obtained with the same input signal levels. Any error
introduced is again expressed as a percentage of reading.
ADC Offset Error
This refers to the dc offset associated with the analog inputs to
the ADCs. It means that with the analog inputs connected to
AGND, the ADCs still see an analog input signal offset.
However, because the HPF is always present, the offset is
removed from the current channel and the power calculation is
not affected by this offset.
Gain Error
The gain error of the ADE7752B is defined as the difference
between the measured output frequency (minus the offset) and
the ideal output frequency. The difference is expressed as a
percentage of the ideal frequency. The ideal frequency is
obtained from the ADE7752B transfer function (see the
Transfer Function section).
相關PDF資料
PDF描述
ADE7752BARWZ-RL Polyphase Energy Metering IC with Pulsed Output
ADE7753 Active and Apparent Energy Metering IC with di/dt sensor interface
ADE7753ARS Active and Apparent Energy Metering IC with di/dt sensor interface
ADE7753ARSRL Active and Apparent Energy Metering IC with di/dt sensor interface
ADE7754 ADE7754
相關代理商/技術參數
參數描述
ADE7752BARWZ-RL 功能描述:IC ENERGY METERING 3PHASE 24SOIC RoHS:是 類別:集成電路 (IC) >> PMIC - 能量測量 系列:- 產品培訓模塊:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 標準包裝:2,500 系列:*
ADE7753 制造商:AD 制造商全稱:Analog Devices 功能描述:Active and Apparent Energy Metering IC with di/dt sensor interface
ADE7753_10 制造商:AD 制造商全稱:Analog Devices 功能描述:Single-Phase Multifunction Metering IC with di/dt Sensor Interface
ADE7753ARS 制造商:Analog Devices 功能描述:Single Phase Multifunction Metering IC 20-Pin SSOP 制造商:Rochester Electronics LLC 功能描述:- Bulk 制造商:Analog Devices 功能描述:IC SEMICONDUTOR ((NS))
ADE7753ARSRL 制造商:Analog Devices 功能描述:Single Phase Multifunction Metering IC 20-Pin SSOP T/R 制造商:Rochester Electronics LLC 功能描述:- Bulk
主站蜘蛛池模板: 博野县| 毕节市| 新乡县| 邛崃市| 娄烦县| 双牌县| 理塘县| 鹤山市| 延寿县| 辽阳市| 民勤县| 清丰县| 高雄市| 盐津县| 蚌埠市| 台北县| 昔阳县| 凭祥市| 沙田区| 枣阳市| 崇州市| 吴旗县| 沈阳市| 新建县| 蒙城县| 泌阳县| 永川市| 色达县| 宝鸡市| 图木舒克市| 平和县| 获嘉县| 丹阳市| 凌源市| 稻城县| 阜阳市| 呼图壁县| 温泉县| 湖北省| 民乐县| 长葛市|