Preliminary Technical Data
ADE7762
TERMINOLOGY
Measurement Error
The error associated with the energy measurement made by the
ADE7762 is defined by the following formula:
Rev. PrB | Page 11 of 28
%
100
Energy
True
Energy
True
7762
ADE
by
Registered
Energy
Error
Percentage
×
=
Error between Channels
The high-pass filter (HPF) in the current channel has a phase
lead response. To offset this phase response and equalize the
phase response between channels, a phase correction network is
placed in the current channel. The phase correction network
ensures a phase match between the current channels and
voltage channels to within ±0.1° over a range of 45 Hz to 65 Hz
and ±0.2° over a range of 40 Hz to 1 kHz (see Figure 28 and
Figure 29).
Power Supply Rejection (PSR)
This quantifies the ADE7762 measurement error as a
percentage of reading when the power supplies are varied.
For the ac PSR measurement, a reading at a nominal supply
(5 V) is taken. A 200 mV rms/100 Hz signal is then introduced
onto the supply and a second reading is obtained under the
same input signal levels. Any error introduced is expressed as a
percentage of reading. See definition for Measurement Error.
For the dc PSR measurement, a reading at nominal supplies
(5 V) is taken. The supply is then varied ±5% and a second
reading is obtained with the same input signal levels. Any error
introduced is again expressed as a percentage of reading.
ADC Offset Error
This refers to the dc offset associated with the analog inputs to
the ADCs. It means that with the analog inputs connected to
AGND, the ADCs still see an analog input signal offset.
However, because the HPF is always present, the offset is
removed from the current channel and the power calculation is
not affected by this offset.
Gain Error
The gain error of the ADE7762 is defined as the difference
between the measured output frequency (minus the offset) and
the ideal output frequency. The difference is expressed as a
percentage of the ideal frequency. The ideal frequency is
obtained from the ADE7762 transfer function (see the Transfer
Function section).
相關PDF資料
PDF描述
ADE7762ARWZ Polyphase Energy Metering IC with Phase Drop Indication
ADE7762ARWZ-RL Polyphase Energy Metering IC with Phase Drop Indication
ADE7768 Energy Metering IC with Integrated Oscillator and Positive Power Accumulation
ADE7768AR Energy Metering IC with Integrated Oscillator and Positive Power Accumulation
ADE7768AR-REF Energy Metering IC with Integrated Oscillator and Positive Power Accumulation
相關代理商/技術參數
參數描述
ADE7762ARWZ 功能描述:IC ENERGY METERING 3PHASE 28SOIC RoHS:是 類別:集成電路 (IC) >> PMIC - 能量測量 系列:- 產品培訓模塊:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 標準包裝:2,500 系列:*
ADE7762ARWZ-RL 功能描述:IC ENERGY METERING 3PHASE 28SOIC RoHS:是 類別:集成電路 (IC) >> PMIC - 能量測量 系列:- 產品培訓模塊:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 標準包裝:2,500 系列:*
ADE7763 制造商:AD 制造商全稱:Analog Devices 功能描述:Single-Phase Active and Apparent Energy Metering IC
ADE7763_13 制造商:AD 制造商全稱:Analog Devices 功能描述:Single-Phase Active and Apparent Energy Metering IC
ADE7763ARS 制造商:Analog Devices 功能描述:Energy Measurement 20-Pin SSOP 制造商:Rochester Electronics LLC 功能描述:1 PHASE ACTIVE AND APPARENT ENERGY IC - Bulk
主站蜘蛛池模板: 淅川县| 北票市| 密山市| 冷水江市| 兰考县| 沐川县| 任丘市| 清河县| 乳源| 新源县| 城步| 商水县| 历史| 治县。| 象山县| 古田县| 鄯善县| 密山市| 大冶市| 松阳县| 华坪县| 任丘市| 沿河| 霍林郭勒市| 西畴县| 黔江区| 宁都县| 永康市| 通山县| 天气| 浪卡子县| 商南县| 济宁市| 女性| 中方县| 锦屏县| 兰坪| 浑源县| 旌德县| 林甸县| 旬邑县|