ADG758/ADG759
–5–
REV. A
ABSOLUTE MAXIMUM RATINGS
1
(T
A
= 25
°
C, unless otherwise noted.)
V
DD
to V
SS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
V
DD
to GND . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +7 V
V
SS
to GND . . . . . . . . . . . . . . . . . . . . . . . . . . +0.3 V to –3.5 V
Analog Inputs
2
. . . . . . . . . . . . . . V
SS
– 0.3 V to V
DD
+0.3 V or
30 mA, Whichever Occurs First
Digital Inputs
2
. . . . . . . . . . . . . . . . . . –0.3 V to V
DD
+0.3 V or
30 mA, Whichever Occurs First
Peak Current, S or D . . . . . . . . . . . . . . . . . . . . . . . . . . 100 mA
(Pulsed at 1 ms, 10% Duty Cycle max)
Continuous Current, S or D . . . . . . . . . . . . . . . . . . . . . 30 mA
Operating Temperature Range
Industrial (B Version) . . . . . . . . . . . . . . . . –40
°
C to +85
°
C
Storage Temperature Range . . . . . . . . . . . . –65
°
C to +150
°
C
Junction Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . 150
°
C
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although
the ADG758/ADG759 features proprietary ESD protection circuitry, permanent damage may
occur on devices subjected to high-energy electrostatic discharges. Therefore, proper ESD
precautions are recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
Chip Scale Package,
θ
JA
Thermal Impedance . . . . . . . . . . . . . . . . . . . . . . 32
°
C/W
Lead Temperature, Soldering
Vapor Phase (60 sec) . . . . . . . . . . . . . . . . . . . . . . . . . 215
°
C
Infrared (15 sec) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220
°
C
NOTES
1
Stresses above those listed under Absolute Maximum Ratings may cause perma-
nent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions above those listed in the operational
sections of this specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device reliability. Only one absolute
maximum rating may be applied at any one time.
2
Overvoltages at EN, A, S, or D will be clamped by internal diodes. Current should
be limited to the maximum ratings given.
Table I. ADG758 Truth Table
A2
A1
A0
EN
Switch Condition
X
0
0
0
0
1
1
1
1
X
0
0
1
1
0
0
1
1
X
0
1
0
1
0
1
0
1
0
1
1
1
1
1
1
1
1
NONE
1
2
3
4
5
6
7
8
X = Don’t Care
Table II. ADG759 Truth Table
A1
A0
EN
ON Switch Pair
X
0
0
1
1
X
0
1
0
1
0
1
1
1
1
NONE
1
2
3
4
X = Don’t Care
ORDERING GUIDE
Model
Temperature Range
–40
°
C to +85
°
C
–40
°
C to +85
°
C
Package Description
Package Option
ADG758BCP
ADG759BCP
20-Lead Chip Scale Package (CSP)
20-Lead Chip Scale Package (CSP)
CP-20
CP-20
PIN CONFIGURATIONS
TOP VIEW
(Not to Scale)
PIN 1
EN
V
SS
S1
S2
S3
GND
V
DD
S5
S6
S7
ADG758
N
20
A
19
A
18
A
17
N
16
S
D
N
N
S
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
NC = NO CONNECT
EXPOSED PAD TIED TO SUBSTRATE, V
SS
TOP VIEW
(Not to Scale)
PIN 1
EN
S1A
S2A
S3A
GND
V
DD
S1B
S2B
S3B
ADG759
N
20
A
19
N
18
A
17
N
16
S
D
N
D
S
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
NC = NO CONNECT
EXPOSED PAD TIED TO SUBSTRATE, V
SS
V
SS