ADM1033
READ OPERATIONS
Receive Byte
Rev. 0 | Page 15 of 40
This operation is useful when repeatedly reading a single
register. The register address must be set up prior to this, with
the MSB at 0 to read a single byte. In this operation, the master
device receives a single byte from a slave device as follows:
1.
The master device asserts a start condition on SDA.
2.
The master sends the 7-bit slave address followed by the
read bit (high).
3.
The addressed slave device asserts ACK on SDA.
4.
The master receives a data byte.
5.
The master sends NO ACK on SDA.
6.
The master asserts a stop condition on SDA and the
transaction ends.
In the ADM1033, the receive-byte protocol is used to read a
single byte from a register whose address has previously been
set by a send-byte or write-byte operation.
SLAVE
ADDRESS
S
DATA
R A
A P
0
Figure 24. Receive Byte
Block Read
In this operation, the master reads a block of data from a slave
device. The number of bytes to be read must be set in advance.
To do this, use
a write-byte operation to the #Bytes/Block Read
Register at Address 0x00. The register address determines
whether a block-read or a read-byte operation is to be
completed (set MSB to 1 to specify a block-read operation). A
maximum number of 32 bytes can be read.
1.
The master asserts a start condition on SDA.
2.
The master sends the 7-bit slave address followed by the
write bit (low).
3.
The addressed slave device asserts ACK on SDA.
4.
The master sends the register address (MSB = 1).
5.
The slave asserts ACK on SDA.
6.
The master asserts a repeated start on SDA.
7.
The master sends the 7-bit slave address followed by the
read bit (high).
8.
The slave asserts ACK on SDA.
9.
The slave sends the byte count.
10.
The master asserts ACK on SDA.
11.
The slave sends N data bytes.
12.
The master asserts ACK on SDA after each data byte.
13.
The master does not acknowledge after the Nth data byte.
14.
The master asserts a stop condition on SDA to end the
transaction.
SLAVE
ADDRESS
S
BYTE
COUNT
DATA 1
REGISTER
ADDRESS
W
A
P
A
A
A DATA N
SLAVE
ADDRESS
S
R
A
0
A
Figure 25. Block Read from RAM
SMBus TIMEOUT
The ADM1033 has a programmable SMBus timeout feature.
When this is enabled, the SMBus typically times out after 25 ms
of no activity. The timeout is disabled by default. It prevents
SMBus hangups by releasing the bus after a period of inactivity.
To enable the SDA timeout, set the SDA timeout bit (Bit 5) of
Configuration Register 1 (Address 0x01) to 1.
To enable the SCL timeout, set the SCL timeout bit (Bit 4) of
Configuration Register 1 (Address 0x01) to 1.
PACKET ERROR CHECKING (PEC)
The ADM1033 supports packet error checking (PEC). This
optional feature is triggered by the extra clock for the PEC byte.
The PEC byte is calculated using CRC-8. The frame check
sequence (FCS) conforms to CRC-8 by the following:
1
)
(
2
8
+
+
+
=
x
x
x
x
C
For more information, consult www.SMBus.org.
ALERT RESPONSE ADDRESS (ARA)
ALERT RESPONSE
ADDRESS
S
DEVICE
ADDRESS
R A
A P
0
Figure 26. Alert Response Address
When multiple devices exist on the same bus, the alert response
address (ARA) feature allows an interrupting device to identify
itself to the host. The ALERT output can be used as an interrupt
output or as an SMBALERT. One or more ALERT outputs can
be connected to a common SMBALERT line, which is
connected to the master. If a device’s ALERT line goes low, the
following procedure occurs:
1.
SMBALERT is pulled low.
2.
The master initiates a receive-byte operation and sends the
alert response address (ARA 0001 100). This is a general call
address that must not be used as a specific device address.
3.
The device with the low ALERT output responds to the
ARA, and the master reads its device address. Once the
address is known, it can be interrogated in the usual way.
4.
If low ALERToutput is detected in more than one device,
the one with the lowest device address has priority, in
accordance with normal SMBus arbitration.
5.
Once the ADM1033 has responded to the ARA, it resets its
ALERT output. If the error persists, the ALERT is re-
asserted on the next monitoring cycle.
相關PDF資料
PDF描述
ADM1033ARQ Thermal Monitor and Fan Speed (RPM) Controller
ADM1033ARQ-REEL Thermal Monitor and Fan Speed (RPM) Controller
ADM1033ARQ-REEL7 Thermal Monitor and Fan Speed (RPM) Controller
ADM1033ARQZ Thermal Monitor and Fan Speed (RPM) Controller
ADM1033ARQZ-REEL Thermal Monitor and Fan Speed (RPM) Controller
相關代理商/技術參數
參數描述
ADM1033ARQ 功能描述:IC THERM/FAN SPEED CTRLR 16-QSOP RoHS:否 類別:集成電路 (IC) >> PMIC - 熱管理 系列:- 標準包裝:1 系列:- 功能:溫度監控系統(傳感器) 傳感器類型:內部和外部 感應溫度:-40°C ~ 125°C,外部傳感器 精確度:±2.5°C 本地(最大值),±5°C 遠程(最大值) 拓撲:ADC,比較器,寄存器庫 輸出類型:2 線 SMBus? 輸出警報:無 輸出風扇:無 電源電壓:2.7 V ~ 5.5 V 工作溫度:-40°C ~ 125°C 安裝類型:表面貼裝 封裝/外殼:SOT-23-8 供應商設備封裝:SOT-23-8 包裝:Digi-Reel® 其它名稱:296-22675-6
ADM1033ARQ-REEL 功能描述:IC THERM/FAN SPEED CTRLR 16-QSOP RoHS:否 類別:集成電路 (IC) >> PMIC - 熱管理 系列:- 標準包裝:1 系列:- 功能:溫度監控系統(傳感器) 傳感器類型:內部和外部 感應溫度:-40°C ~ 125°C,外部傳感器 精確度:±2.5°C 本地(最大值),±5°C 遠程(最大值) 拓撲:ADC,比較器,寄存器庫 輸出類型:2 線 SMBus? 輸出警報:無 輸出風扇:無 電源電壓:2.7 V ~ 5.5 V 工作溫度:-40°C ~ 125°C 安裝類型:表面貼裝 封裝/外殼:SOT-23-8 供應商設備封裝:SOT-23-8 包裝:Digi-Reel® 其它名稱:296-22675-6
ADM1033ARQ-REEL7 功能描述:IC THERM/FAN SPEED CTRLR 16-QSOP RoHS:否 類別:集成電路 (IC) >> PMIC - 熱管理 系列:- 標準包裝:1 系列:- 功能:溫度監控系統(傳感器) 傳感器類型:內部和外部 感應溫度:-40°C ~ 125°C,外部傳感器 精確度:±2.5°C 本地(最大值),±5°C 遠程(最大值) 拓撲:ADC,比較器,寄存器庫 輸出類型:2 線 SMBus? 輸出警報:無 輸出風扇:無 電源電壓:2.7 V ~ 5.5 V 工作溫度:-40°C ~ 125°C 安裝類型:表面貼裝 封裝/外殼:SOT-23-8 供應商設備封裝:SOT-23-8 包裝:Digi-Reel® 其它名稱:296-22675-6
ADM1033ARQZ 功能描述:馬達/運動/點火控制器和驅動器 +/- 1 C Digital 2-Wire RoHS:否 制造商:STMicroelectronics 產品:Stepper Motor Controllers / Drivers 類型:2 Phase Stepper Motor Driver 工作電源電壓:8 V to 45 V 電源電流:0.5 mA 工作溫度:- 25 C to + 125 C 安裝風格:SMD/SMT 封裝 / 箱體:HTSSOP-28 封裝:Tube
ADM1033ARQZ-REEL 功能描述:板上安裝溫度傳感器 +/- 1 C Digital 2-Wire RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關閉: 安裝風格: 封裝 / 箱體: 設備功能:Temperature and Humidity Sensor
主站蜘蛛池模板: 禹城市| 徐州市| 大庆市| 广南县| 恩平市| 蒙自县| 江都市| 桓台县| 徐州市| 柘荣县| 济源市| 昆明市| 成武县| 龙山县| 房产| 西乌珠穆沁旗| 石首市| 石景山区| 东丰县| 陵水| 巴里| 吴忠市| 涟源市| 玉树县| 遵义市| 石嘴山市| 南召县| 东平县| 玉林市| 安宁市| 怀柔区| 奇台县| 兰溪市| 乌兰察布市| 高陵县| 广河县| 钟祥市| 谢通门县| 静海县| 南康市| 芜湖县|