型號: ADM6318CY46ARJ
廠商: ANALOG DEVICES INC
元件分類: 電源管理
英文描述: Supervisory Circuits with Watchdog and Manual Reset in 5-Lead SOT-23
中文描述: 1-CHANNEL POWER SUPPLY MANAGEMENT CKT, PDSO5
封裝: SOT-23, 5 PIN
文件頁數: 9/11頁
文件大小: 255K
代理商: ADM6318CY46ARJ
ADM6316/ADM6317/ADM6318/ADM6319/ADM6320/ADM6321/ADM6322
Table 5. Reset Threshold Options
Rev.PrC | Page 9 of 11
Table 6. Reset Timeout Options
Suffix
Min
A
1
B
20
C
140
D
1.12
Typ
1.6
30
200
1.60
Max
2
40
280
2.24
Unit
ms
ms
ms
s
Table 8. Standard Models
Table 7. Watchdog Timer Operations
Suffix
Min
W
4.3
X
71
Y
1.12
Z
17.9
Typ
6.3
102
1.6
25.6
Max
9.3
153
2.24
38.4
Unit
ms
ms
s
s
T
A
= +25°C
Typ
5.000
4.900
4.800
4.700
4.630
4.500
4.390
4.300
4.200
4.100
4.00
3.900
3.800
3.700
3.600
3.500
3.400
3.300
3.200
3.080
3.000
2.930
2.800
2.700
2.630
2.500
T
A
= 40°C to +85°C
Min
4.875
4.778
4.680
4.583
4.514
4.388
4.270
4.193
4.095
3.998
3.900
3.803
3.705
3.608
3.510
3.413
3.315
3.218
3.120
3.003
2.925
2.857
2.730
2.633
2.564
2.438
Part No.
Min
4.925
4.827
4.728
4.630
4.561
4.433
4.314
4.236
4.137
4.039
3.940
3.842
3.743
3.645
3.546
3.448
3.349
3.251
3.152
3.034
2.955
2.886
2.758
2.660
2.591
2.463
Max
5.075
4.974
4.872
4.771
4.699
4.568
4.446
4.365
4.263
4.162
4.060
3.959
3.857
3.756
3.654
3.553
3.451
3.350
3.248
3.126
3.045
2.974
2.842
2.741
2.669
2.538
Max
5.125
5.023
4.920
4.818
4.746
4.613
4.490
4.408
4.305
4.203
4.100
3.998
3.895
3.793
3.690
3.588
3.485
3.383
3.280
3.157
3.075
3.000
2.870
2.768
2.696
2.563
ADM63 _ _ _ 50
ADM63 _ _ _ 49
ADM63 _ _ _ 48
ADM63 _ _ _ 47
ADM63 _ _ _ 46
ADM63 _ _ _ 45
ADM63 _ _ _ 44
ADM63 _ _ _ 43
ADM63 _ _ _ 42
ADM63 _ _ _ 41
ADM63 _ _ _ 40
ADM63 _ _ _ 39
ADM63 _ _ _ 38
ADM63 _ _ _ 37
ADM63 _ _ _ 36
ADM63 _ _ _ 35
ADM63 _ _ _ 34
ADM63 _ _ _ 33
ADM63 _ _ _ 32
ADM63 _ _ _ 31
ADM63 _ _ _ 30
ADM63 _ _ _ 29
ADM63 _ _ _ 28
ADM63 _ _ _ 27
ADM63 _ _ _ 26
ADM63 _ _ _ 25
Model
ADM6316CY29ARJ
ADM6316CY46ARJ
ADM6318CY46ARJ
ADM6319C46ARJ
ADM6320CY29ARJ
ADM6320CY46ARJ
ADM6321CY46ARJ
ADM6322C46ARJ
Reset Threshold (V)
2.93
4.63
4.63
4.63
2.93
4.63
4.63
4.63
Minimum Reset Timeout (ms)
140
140
140
140
140
140
140
140
Typical Watchdog Timeout (s)
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
PRELIMINARY TECHNICAL DATA
相關PDF資料
PDF描述
ADM6319 Supervisory Circuits with Watchdog and Manual Reset in 5-Lead SOT-23
ADM6319C46ARJ Supervisory Circuits with Watchdog and Manual Reset in 5-Lead SOT-23
ADM6320 Supervisory Circuits with Watchdog and Manual Reset in 5-Lead SOT-23
ADM6320CY29ARJ Supervisory Circuits with Watchdog and Manual Reset in 5-Lead SOT-23
ADM6320CY46ARJ Supervisory Circuits with Watchdog and Manual Reset in 5-Lead SOT-23
相關代理商/技術參數
參數描述
ADM6318CY46-ARJ-RL7 制造商:AD 制造商全稱:Analog Devices 功能描述:Supervisory Circuits with Watchdog and Manual Reset in 5-Lead SOT-23
ADM6318CY46ARJ-RL7 功能描述:IC SUPERVISOR WATCHDOG SOT23-5 RoHS:否 類別:集成電路 (IC) >> PMIC - 監控器 系列:- 標準包裝:400 系列:- 類型:備用電池電路 監視電壓數目:1 輸出:開路漏極,推挽式 復位:高有效/低有效 復位超時:最小為 35 ms 電壓 - 閥值:4.65V 工作溫度:-40°C ~ 85°C 安裝類型:表面貼裝 封裝/外殼:16-SOIC(0.295",7.50mm 寬) 供應商設備封裝:16-SOIC W 包裝:帶卷 (TR) 其它名稱:ADM691ARZ-REEL7TR
ADM6318CY46-ARJZ-R7 制造商:AD 制造商全稱:Analog Devices 功能描述:Supervisory Circuits with Watchdog and Manual Reset in 5-Lead SOT-23
ADM6318CY46ARJZ-R7 功能描述:IC SUPERVISOR W/RESET SOT23-5 RoHS:是 類別:集成電路 (IC) >> PMIC - 監控器 系列:- 標準包裝:3,000 系列:- 類型:簡單復位/加電復位 監視電壓數目:1 輸出:推挽式,圖騰柱 復位:高有效 復位超時:最小為 100 ms 電壓 - 閥值:3.06V 工作溫度:-40°C ~ 105°C 安裝類型:表面貼裝 封裝/外殼:SC-70,SOT-323 供應商設備封裝:SC-70-3 包裝:帶卷 (TR) 其它名稱:ADM1817-5AKSREEL7
ADM6318CZ28-ARJ-RL7 制造商:AD 制造商全稱:Analog Devices 功能描述:Supervisory Circuits with Watchdog and Manual Reset in 5-Lead SOT-23
主站蜘蛛池模板: 临城县| 砀山县| 家居| 兰坪| 洪洞县| 涿州市| 武山县| 镇坪县| 永城市| 石景山区| 河津市| 广元市| 讷河市| 安塞县| 东山县| 元阳县| 乌兰察布市| 宁河县| 民县| 六盘水市| 北辰区| 南京市| 肥东县| 威远县| 镇巴县| 阳东县| 察隅县| 班玛县| 开阳县| 习水县| 兴文县| 庆云县| 闵行区| 准格尔旗| 高青县| 象山县| 沽源县| 海丰县| 垣曲县| 枝江市| 尚义县|