REV. 0
ADM6711/ADM6713
–3–
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although the
ADM6711/ADM6713 feature proprietary ESD protection circuitry, permanent damage may occur on
devices subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are
recommended to avoid performance degradation or loss of functionality.
ABSOLUTE MAXIMUM RATINGS
*
(T
A
= 25
°
C, unless otherwise noted.)
V
CC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +6 V
RESET
(Push-Pull) . . . . . . . . . . . . . . –0.3 V to (V
CC
+ 0.3 V)
RESET
(Open-Drain) . . . . . . . . . . . . . . . . . . . –0.3 V to +6 V
MR
. . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to (V
CC
+ 0.3 V)
Input Current
V
CC
,
MR
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 mA
Output Current
RESET
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 mA
Rate of Rise, V
CC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 V/
μ
s
JA
Thermal Impedance, SC70 . . . . . . . . . . . . . . . . . 146
°
C/W
Operating Temperature Range . . . . . . . . . . –40
°
C to +125
°
C
Storage Temperature Range . . . . . . . . . . . . –65
°
C to +150
°
C
Lead Temperature (Soldering, 10 sec) . . . . . . . . . . . . . 300
°
C
*
Stresses above those listed under Absolute Maximum Ratings may cause perma-
nent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions above those listed in the operational
sections of this specification is not implied. Exposure to absolute maximum ratings
for extended periods of time may affect device reliability.
ORDERING GUIDE
Temperature Range
–40
°
C to +125
°
C
–40
°
C to +125
°
C
–40
°
C to +125
°
C
–40
°
C to +125
°
C
–40
°
C to +125
°
C
–40
°
C to +125
°
C
–40
°
C to +125
°
C
–40
°
C to +125
°
C
–40
°
C to +125
°
C
–40
°
C to +125
°
C
–40
°
C to +125
°
C
–40
°
C to +125
°
C
–40
°
C to +125
°
C
–40
°
C to +125
°
C
–40
°
C to +125
°
C
–40
°
C to +125
°
C
–40
°
C to +125
°
C
–40
°
C to +125
°
C
–40
°
C to +125
°
C
–40
°
C to +125
°
C
–40
°
C to +125
°
C
–40
°
C to +125
°
C
–40
°
C to +125
°
C
–40
°
C to +125
°
C
Model
RESET
Threshold (V)
Branding
Quantity (k)
ADM6711LAKS-REEL
ADM6711LAKS-REEL-7
ADM6711MAKS-REEL
ADM6711MAKS-REEL-7
ADM6711TAKS-REEL
ADM6711TAKS-REEL-7
ADM6711SAKS-REEL
ADM6711SAKS-REEL-7
ADM6711RAKS-REEL
ADM6711RAKS-REEL-7
ADM6711ZAKS-REEL
ADM6711ZAKS-REEL-7
ADM6713LAKS-REEL
ADM6713LAKS-REEL-7
ADM6713MAKS-REEL
ADM6713MAKS-REEL-7
ADM6713TAKS-REEL
ADM6713TAKS-REEL-7
ADM6713SAKS-REEL
ADM6713SAKS-REEL-7
ADM6713RAKS-REEL
ADM6713RAKS-REEL-7
ADM6713ZAKS-REEL
ADM6713ZAKS-REEL-7
4.63
4.63
4.38
4.38
3.08
3.08
2.93
2.93
2.63
2.63
2.32
2.32
4.63
4.63
4.38
4.38
3.08
3.08
2.93
2.93
2.63
2.63
2.32
2.32
M0B
M0B
M0C
M0C
M0D
M0D
M0E
M0E
M0F
M0F
M0G
M0G
M0H
M0H
M0J
M0J
M0K
M0K
M0L
M0L
M0M
M0M
M0N
M0N
10
3
10
3
10
3
10
3
10
3
10
3
10
3
10
3
10
3
10
3
10
3
10
3
Table I.
RESET
Threshold Options
Model
RESET
Threshold (V)
ADM671_L
ADM671_M
ADM671_T
ADM671_S
ADM671_R
ADM671_Z
4.63
4.38
3.08
2.93
2.63
2.32