欧美成人免费电影,国产欧美一区二区三区精品酒店,精品国产a毛片,色网在线免费观看

參數資料
型號: ADT7519ARQZ1
廠商: Analog Devices, Inc.
元件分類: 溫度/濕度傳感器
英文描述: SPI/I2C Compatible, Temperature Sensor, Four Channel ADC and Quad Voltage Output DAC
中文描述: SPI/I2C兼容,溫度傳感器,四通道ADC和四路電壓輸出DAC
文件頁數: 12/44頁
文件大小: 1350K
代理商: ADT7519ARQZ1
ADT7516/ADT7517/ADT7519
DAC-to-DAC Crosstalk
This is the glitch impulse transferred to the output of one DAC
due to a digital code change and subsequent output change of
another DAC. This includes both digital and analog crosstalk. It
is measured by loading one of the DACs with a full-scale code
change (all 0s to all 1s and vice versa) with LDAC low and
monitoring the output of another DAC. The energy of the glitch
is expressed in nV-s.
Multiplying Bandwidth
The amplifiers within the DAC have a finite bandwidth. The
multiplying bandwidth is a measure of this. A sine wave on the
reference (with full-scale code loaded to the DAC) appears on
the output. The multiplying bandwidth is the frequency at
which the output amplitude falls to 3 dB below the input.
Total Harmonic Distortion
This is the difference between an ideal sine wave and its
attenuated version using the DAC. The sine wave is used as the
reference for the DAC, and the THD is a measure of the
harmonics present on the DAC output, expressed in dB.
Round Robin
This term is used to describe the ADT7516/ADT7517/
ADT7519 cycling through the available measurement channels
in sequence, taking a measurement on each channel.
DAC Output Settling Time
This is the time required, following a prescribed data change, for
the output of a DAC to reach and remain within ±0.5 LSB of the
final value. A typical prescribed change is from 1/4 scale to
3/4 scale.
Rev. A | Page 12 of 44
AMPLIFIER
FOOTROOM
LOWER
DEADBAND
CODES
NEGATIVE
OFFSET
ERROR
GAIN ERROR
+
OFFSET ERROR
ACTUAL
IDEAL
OUTPUT
VOLTAGE
NEGATIVE
OFFSET
ERROR
DAC CODE
0
Figure 8. DAC Transfer Function with Negative Offset
ACTUAL
IDEAL
GAIN ERROR
+
OFFSET ERROR
UPPER
DEADBAND
CODES
OUTPUT
VOLTAGE
POSITIVE
OFFSET
ERROR
DAC CODE
FULL SCALE
0
Figure 9. DAC Transfer Function with Positive Offset (V
REF
= V
DD
)
相關PDF資料
PDF描述
ADT7519ARQZ1-REEL SPI/I2C Compatible, Temperature Sensor, Four Channel ADC and Quad Voltage Output DAC
ADT7519ARQZ1-REEL7 SPI/I2C Compatible, Temperature Sensor, Four Channel ADC and Quad Voltage Output DAC
ADT7516ARQ SPI/I2C Compatible, Temperature Sensor, Four Channel ADC and Quad Voltage Output DAC
ADT7517ARQ SPI/I2C Compatible, Temperature Sensor, Four Channel ADC and Quad Voltage Output DAC
ADT7519ARQ SPI/I2C Compatible, Temperature Sensor, Four Channel ADC and Quad Voltage Output DAC
相關代理商/技術參數
參數描述
ADT7519ARQZ1-REEL 制造商:AD 制造商全稱:Analog Devices 功能描述:SPI/I2C Compatible, Temperature Sensor, Four Channel ADC and Quad Voltage Output DAC
ADT7519ARQZ1-REEL7 制造商:AD 制造商全稱:Analog Devices 功能描述:SPI/I2C Compatible, Temperature Sensor, Four Channel ADC and Quad Voltage Output DAC
ADT7519ARQZ-REEL 功能描述:IC SENSOR TEMP QD ADC/DAC 16QSOP RoHS:是 類別:集成電路 (IC) >> PMIC - 熱管理 系列:- 標準包裝:2,500 系列:SilentSense™ 功能:溫度監控系統(傳感器) 傳感器類型:內部和外部 感應溫度:-55°C ~ 125°C,外部傳感器 精確度:±2°C 本地(最大),±3°C 遠程(最大) 拓撲:ADC(三角積分型),比較器,寄存器庫 輸出類型:I²C?/SMBus? 輸出警報:是 輸出風扇:是 電源電壓:2.7 V ~ 5.5 V 工作溫度:-55°C ~ 125°C 安裝類型:表面貼裝 封裝/外殼:8-TSSOP,8-MSOP(0.118",3.00mm 寬) 供應商設備封裝:8-MSOP 包裝:帶卷 (TR) 其它名稱:MIC284-2BMMTRMIC284-2BMMTR-ND
ADT7519ARQZ-REEL7 功能描述:IC SENSOR TEMP QD ADC/DAC 16QSOP RoHS:是 類別:集成電路 (IC) >> PMIC - 熱管理 系列:- 標準包裝:2,500 系列:SilentSense™ 功能:溫度監控系統(傳感器) 傳感器類型:內部和外部 感應溫度:-55°C ~ 125°C,外部傳感器 精確度:±2°C 本地(最大),±3°C 遠程(最大) 拓撲:ADC(三角積分型),比較器,寄存器庫 輸出類型:I²C?/SMBus? 輸出警報:是 輸出風扇:是 電源電壓:2.7 V ~ 5.5 V 工作溫度:-55°C ~ 125°C 安裝類型:表面貼裝 封裝/外殼:8-TSSOP,8-MSOP(0.118",3.00mm 寬) 供應商設備封裝:8-MSOP 包裝:帶卷 (TR) 其它名稱:MIC284-2BMMTRMIC284-2BMMTR-ND
ADT7519ARZQ 制造商:Analog Devices 功能描述: