45
SMALL DIMENSION (ELECTRONIC) FUSES
ABC
Fast-Acting
Physical Size:
1/4” x 1-1/4”
(6.3mm x 32mm)
Construction:
Ceramic Tube
Voltage Rating: See Below
Interrupting Rating: See Below
Agency Approvals:
UL Listed product meets standard 248-14
UL Listed Guide & File numbers (ABC
1/4-15A): JDYX & E19180.
UL Recognition Guide & File numbers
(ABC 20-30A): JDYX2 & E19180.
CSA Certification Record No: 053787
C 000 & Class No: 1422 01 & 1422
30.
Electrical Characteristics
Current
Rated
AC Interrupting
Rating
Voltage
Rating1
AC (Max.)
DC (Max.)
250V
125V
1/4
250V
125V
35A 10000A
1/2
250V
125V
35A 10000A
3/4
250V
125V
35A 10000A
1
250V
125V
35A 10000A
1-1/2
250V
125V
100A 10000A
2
250V
125V
100A 10000A
2-1/2
250V
125V
100A 10000A
3
250V
125V
100A 10000A
4
250V
125V
200A 10000A
5
250V
125V
200A 10000A
6
250V
125V
200A 10000A
7
250V
125V
200A 10000A
8
250V
125V
200A 10000A
10
250V
125V
200A 10000A
12
250V
125V
200A 10000A
15
250V
125V
750A 10000A
20
250V
125V
400A 1000A
25
125V
–
1000A
30
125V
–
1000A
1Interrupting ratings were measured at 70% - 80% power factor on
AC, and at a time constant described in UL 198L.
CROSS REFERENCE
NEW
OLD
EDISON
BUSS
GOULD
LF
ABC
BBC
ABC
GAB
314
AGC
Fast-Acting
Physical Size:
1/4” x 1-1/4”
(6.3mm x 32mm)
Construction:
Glass Tube, Nickel-
plated brass endcaps.
Voltage Rating: See Below
Interrupting Rating: See Below
Agency Approvals:
UL Listed product meets standard 248-14
UL Listed Card: AGC 1/500-10
UL Recognition Card: AGC 11-30
CSA Component Acceptance Card
(Class No. 1422 30)
CSA Certification Card (Class No.
1422 01)
Electrical Characteristics
Current
Rated
AC Interrupting
Rating
Voltage
Rating1
AC (Max.)
250V
125V
32V
1/20
250V
35V
10000A
1000A
1/16
250V
35V
10000A
1000A
1/10
250V
35V
10000A
1000A
1/8
250V
35V
10000A
1000A
3/16
250V
35V
10000A
1000A
2/10
250V
35V
10000A
1000A
1/4
250V
35V
10000A
1000A
3/10
250V
35V
10000A
1000A
3/8
250V
35V
10000A
1000A
45/100
250V
35V
10000A
1000A
1/2
250V
35V
10000A
1000A
3/4
250V
35V
10000A
1000A
1
250V
35V
10000A
1000A
1-1/4
250V
100A
10000A
1000A
1-1/2
250V
100A
10000A
1000A
2
250V
100A
10000A
1000A
2-1/4
125V
100A
10000A
1000A
2-1/2
125V
100A
10000A
1000A
3
125V
100A
10000A
1000A
4
125V
200A
10000A
1000A
5
125V
200A
10000A
1000A
6
125V
200A
10000A
1000A
7
125V
200A
10000A
1000A
8
125V
200A
10000A
1000A
9
125V
200A
10000A
1000A
10
125V
200A
10000A
1000A
15
32V
–
1000A
20
32V
–
1000A
25
32V
–
1000A
30
32V
–
1000A
1Interrupting ratings were measured at 70% - 80% power factor on
AC, and at a time constant described in UL 198L.
CROSS REFERENCE
NEW
OLD
EDISON
BUSS
GOULD
LF
AGC
BGC
AGC
GGC
312
GBB
Very Fast-Acting
Physical Size:
1/4” x 1-1/4”
(6.3mm x 32mm)
Construction:
Ceramic Tube
Voltage Rating: See Below
Agency Approvals:
UL recognized product meets standard 248-
14
UL Recognized Card: GBB 1-30A (JFHR2,
E56412)
CSA Component Certified Card (Class
1422-01 File 53787)
Product Code & Voltage Rating
Product
Voltage
Code
Rating
AC
DC
GBB-1
250V
125V
GBB-1-1/4
250V
125V
GBB-2
250V
125V
GBB-3
250V
125V
GBB-4
250V
125V
GBB-5
250V
125V
GBB-6
250V
125V
GBB-7
250V
125V
GBB-8
250V
125V
GBB-9
250V
125V
GBB-10
250V
125V
GBB-12
250V
125V
GBB-15
250V
125V
GBB-20
250V
125V
GBB-25
125V
GBB-30
125V
CROSS REFERENCE
NEW
OLD
EDISON
BUSS
GOULD
LF
GBB
—
GBB
None
322
1/4” x 1-1/4” Fast-Acting Fuses