GU-E PhotoMOS (AQW414EH)
1
2
3
4
8
7
6
5
GU-E PhotoMOS
(AQW414EH)
General use and economy type.
DIP (2 Form B) 8-pin type.
Reinforced insulation 5,000V
type.
mm
inch
3.2
.126
6.4
.252
9.86
.388
2.9
.114
6.4
.252
9.86
.388
FEATURES
1. Reinforced insulation 5,000 V type
More than 0.4 mm internal insulation
distance between inputs and outputs.
Con-forms to EN41003, EN60950
(reinforced insulation).
2. Compact 8-pin DIP size
The device comes in a compact
(W)6.4
×
(L)9.86
×
(H)3.2 mm
(W).252
×
(L).388
×
(H).126 inch
, 8-pin DIP
size (through hole terminal type).
3. Applicable for 2 Form B use as well
as two independent 1 Form B use
4. Controls low-level analog signals
PhotoMOS relays feature extremely low
closed-circuit offset voltage to enable
control of low-level analog signals without
distortion.
5. High sensitivity, high speed
response.
Can control a maximum 0.13 A load
current with a 5 mA input current. Fast
operation speed of 0.8 ms (typical).
6. Low-level off state leakage current
TYPICAL APPLICATIONS
Modem
Telephone equipment
Security equipment
Sensors
TYPES
*Indicate the peak AC and DC values.
Note:
For space reasons, the SMD terminal shape indicator "A" and the package type indicator "X" and "Z" are omitted from the seal.
Type
I/O isolation
voltage
Output rating*
Part No.
Packing quantity
Through hole
terminal
Surface-mount terminal
Load
voltage
Load
current
Tube packing style
Tape and reel packing style
Picked from the
1/2/3/4-pin side
Tube
Tape and
reel
Picked from the
5/6/7/8-pin side
AC/DC
type
Reinforced
5,000 V
400 V
100 mA
AQW414EH
AQW414EHA
AQW414EHAX
AQW414EHAZ
1 tube contains
40 pcs.
1 batch contains
400 pcs.
1,000 pcs.
RATING
1. Absolute maximum ratings (Ambient temperature: 25
Item
LED forward current
LED reverse voltage
Peak forward current
Power dissipation
Load voltage (peak AC)
°
C
77
°
F
)
AQW414EH (A)
50mA
5V
1A
75mW
400 V
Symbol
I
F
V
I
FP
P
V
Remarks
Input
R
f =100 Hz, Duty factor = 0.1%
in
Output
L
Continuous load current
I
L
0.1 A (0.13 A)
Peak AC, DC
( ): in case of using only 1 channel.
100 ms (1 shot), V
Peak load current
Power dissipation
I
P
P
V
T
T
peak
0.3 A
800mW
850mW
5,000 V AC
°
C
–40
°
C
–40
L
= DC
out
Total power dissipation
I/O isolation voltage
T
iso
Temperature
limits
Operating
Storage
opr
–40
–40
°
C to +100
C to +85
°
F to +185
°
F to +212
°
F
°
Non-condensing at low temperatures
stg
°
F
TESTING
All Rights Reserved C
OPYRIGHT
Matsushita Electric Works, Ltd.