HS SOP 1 Form A (AQY2)
TYPES
Note: For space reasons, the three initial letters of the part number “AQY”, the surface mount terminal indicator “S” and the packing style indicator “X” or “Z” are not marked
on the relay. (Ex. the label for product number AQY232SX is 232.)
* Indicate the peak AC and DC values.
Ratings and packages other than those given above are available by special order. Please contact our sales ofce in your area.
RATING
1. Absolute maximum ratings (Ambient temperature: 25
°C 77°F)
Recommended LED forward
current 2 mA, High Sensitivity
(Low current-consumption),
Miniature SOP4-pin Type
HS SOP 1 Form A
(AQY2)
Output rating*
Package
Part No.
Packing quantity
Load
voltage
Load
current
Tube packing style
Tape and reel packing style
Tube
Tape and reel
Picked from the
1/2-pin side
Picked from the
3/4-pin side
AC/DC
dual use
60V
500mA
SOP4-pin
AQY232S
AQY232SX
AQY232SZ
1 tube contains:
100 pcs.
1 batch contains:
2,000 pcs.
1,000 pcs.
350V
120mA
AQY230S
AQY230SX
AQY230SZ
400V
100mA
AQY234S
AQY234SX
AQY234SZ
Item
Symbol
AQY232S
AQY230S
AQY234S
Remarks
Input
LED forward current
IF
50 mA
LED reverse voltage
VR
5 V
Peak forward current
IFP
1 A
f = 100 Hz, Duty factor = 0.1%
Power dissipation
Pin
75 mW
Output
Load voltage (peak AC)
VL
60 V
350 V
400 V
Continuous load current
IL
0.5 A
0.12 A
0.1 A
Peak AC, DC
Peak load current
Ipeak
1.5 A
0.3 A
0.24 A
100ms (1 shot), VL = DC
Power dissipation
Pout
300 mW
Total power dissipation
PT
350 mW
I/O isolation voltage
Viso
1,500 V AC
Operating temperature
Topr
–40
°C to +85°C –40°F to +185°F
Non-condensing at low temperatures
Storage temperature
Tstg
–40
°C to +100°C –40°F to +212°F
mm inch
FEATURES
1. High sensitivity (Low current-
consumption)
HS type PhotoMOS relays need less than
half LED forward current of other types.
This contributes to energy-saving
working of equipment and longer
operating life for battery.
In case of load voltage 60V type, SOP4-pin
2. Small package (SOP4-pin)
3. 60 V, 350 V and 400 V load voltage
types available
TYPICAL APPLICATIONS
Ideal for battery-powered devices that
need to lengthen operating life.
Also recommended for power-
economizing of testing equipment that
uses many relays.
1. Security equipment
Crime-preventing system: Surveillance
camera, burglar alarm
Disaster-preventing system: Fire alarm,
heat/smoke sensor
2. Measuring instruments
3. Meters (watt-hour, gas, etc.)
4. Telecommunication equipment
5. Industrial equipment
4.4
2.1
4.3
.173
.083
.169
2
4
1
3
Compliance with RoHS Directive
Sensitivity comparison between
HS type and GU type
HS type
(AQY232S)
GU type
(AQY212S)
LED
operate
current
Typical
0.35 mA
0.9 mA
Maximum
0.5 mA
3 mA
Recommended LED
forward current
2 mA
5 mA
New