1/7
Table 1: Main Features
DESCRIPTION
Available either in through-hole or surface-mount
packages, the
BTA10
and
BTB10
triac series is
suitable for general purpose AC switching. They
can be used as an ON/OFF function in applica-
tions such as static relays, heating regulation, in-
duction motor starting circuits... or for phase
control operation in light dimmers, motor speed
controllers,...
The snubberless version (W suffix) is specially
recommended for use on inductive loads, thanks
to their high commutation performances.
By using an internal ceramic pad, the BTA series
provides
voltage
insulated
2500V
RMS
) complying with UL standards (File ref.:
E81734).
tab
(rated
at
Symbol
Value
Unit
I
T(RMS)
10
A
V
DRM
/V
RRM
600 and 800
V
I
GT (Q
1
)
25 to 50
mA
BTA10 and BTB10 Series
10A TRIAC
S
REV. 6
February 2006
SNUBBERLESS & STANDARD
Table 2: Order Codes
Part Number
BTA10-xxxxxRG
BTB10-xxxxxRG
Marking
See page table 8 on
page 6
G
A2
A1
G
A2
A2
A1
TO-220AB Insulated
(BTA10)
TO-220AB
(BTB10)
A2
A1
G
Table 3: Absolute Maximum Ratings
Symbol
Parameter
Value
Unit
I
T(RMS)
RMS on-state current (full sine
wave)
TO-220AB
TO-220AB Ins.
F = 50 Hz
F = 60 Hz
t
p
= 10 ms
T
c
= 105°C
T
c
= 95°C
t = 20 ms
t = 16.7 ms
10
A
I
TSM
Non repetitive surge peak on-state
current (full cycle, T
j
initial = 25°C)
I
2
t Value for fusing
Critical rate of rise of on-state cur-
rent I
G
= 2 x I
GT
, t
r
≤
100 ns
Non repetitive surge peak off-state
voltage
100
105
55
A
I
2
t
A
2
s
dI/dt
F = 120 Hz
T
j
= 125°C
50
A/μs
V
DSM
/V
RSM
t
p
= 10 ms
T
j
= 25°C
V
DSM
/V
RSM
+ 100
4
1
V
I
GM
P
G(AV)
T
stg
T
j
Peak gate current
Average gate power dissipation
t
p
= 20 μs
T
j
= 125°C
T
j
= 125°C
A
W
Storage junction temperature range
Operating junction temperature range
- 40 to + 150
- 40 to + 125
°C