1/6
MAIN FEATURES:
BTA/BTB10 Series
SNUBBERLESS
& STANDARD
10A TRIAC
S
April 2002 - Ed: 5A
DESCRIPTION
Available either in standard or snubberless
version, the BTA/BTB10 triac series is suitable for
general purpose AC switching. They can be used
as an ON/OFF function in applications such as
static relays, heating regulation, induction motor
starting circuits... or for phase control operation in
light dimmers, motor speed controllers, ...
The snubberless version (W suffix) is specially
recommended for use on inductive loads, thanks
to their high commutation performances.
By using an internal ceramic pad, the BTA series
provides voltage insulated tab (rated at 2500 V
RMS) complying with UL standards (File ref.:
E81734).
Symbol
Value
Unit
I
T(RMS)
10
A
V
DRM
/V
RRM
600 and 800
V
I
GT (Q
1
)
25 to 50
mA
ABSOLUTE MAXIMUM RATINGS
Symbol
Parameter
Value
Unit
I
T(RMS)
RMS on-state current
(full sine wave)
TO-220AB
Tc = 105°C
10
A
TO-220AB Ins.
Tc = 95°C
I
TSM
Non repetitive surge peak on-state
current (full cycle, Tj initial = 25°C)
F = 60 Hz
t = 16.7 ms
105
A
F = 50 Hz
t = 20 ms
100
I
2
t
I
2
t Value for fusing
tp = 10 ms
55
A
2
s
dI/dt
Critical rate of rise of on-state current
I
G
= 2 x I
GT
, tr
≤
100 ns
F = 120 Hz
Tj = 125°C
50
A/μs
V
DSM
/V
RSM
Non repetitive surge peak off-state
voltage
tp = 10 ms
Tj = 25°C
V
DRM
/V
RRM
+ 100
V
I
GM
Peak gate current
tp = 20 μs
Tj = 125°C
4
A
P
G(AV)
Average gate power dissipation
Tj = 125°C
1
W
T
stg
T
j
Storage junction temperature range
Operating junction temperature range
- 40 to + 150
- 40 to + 125
°C
G
A2
A1
G
A2
A2
A1
G
A2
A1
TO-220AB Insulated
(BTA10)
TO-220AB
(BTB10)