欧美成人免费电影,国产欧美一区二区三区精品酒店,精品国产a毛片,色网在线免费观看

參數(shù)資料
型號: CM1901-7ERV2H
廠商: POWER-ONE INC
元件分類: 電源模塊
英文描述: 1-OUTPUT 50 W DC-DC REG PWR SUPPLY MODULE
封裝: METAL, CASE M02, MODULE
文件頁數(shù): 9/25頁
文件大小: 569K
代理商: CM1901-7ERV2H
Cassette Style
DC-DC Converters
M Series
Edition 01/01.2001
17/25
Table 14: Pin allocation
Electrical determination
A…LM 1000
C...LMZ 1000
A…LM 2000
C...LMZ 2000
A…LM 3000
C...LMZ 3000
Pin
Ident
Pin
Ident
Pin
Ident
Pin
Ident
Pin
Ident
Pin
Ident
Inhibit control input
2
i
2
i
2
i
2
i
2
i
2
i
Safe Data or ACFAIL
5
D or V
5
D or V
5
D or V
5
D or V
5
D or V
5
D or V
Output voltage (positive)
8
Vo1+
8
Vo1+
8
Vo3+
8
Vo3+
Output voltage (negative)
11
Vo1–
11
Vo1–
11
Vo3–
11
Vo3–
Control input + 1
14
R
14
R
Control input –
17
G
17
G
Output voltage (positive)
14
Vo2+
14
Vo2+
14
Vo2+
14
Vo2+
Output voltage (negative)
17
Vo2–
17
Vo2–
17
Vo2–
17
Vo2–
Output voltage (positive)
20
Vo1+
20
Vo1+
20
Vo1+
20
Vo1+
20
Vo1+
20
Vo1+
Output voltage (negative)
23
Vo1–
23
Vo1–
23
Vo1–
23
Vo1–
23
Vo1–
23
Vo1–
Protective earthing 2
26
DC input voltage 3
29
Vi+
29
Vi+
29
Vi+
29
Vi+
29
Vi+
29
Vi+
DC input voltage
32
Vi–
32
Vi–
32
Vi–
32
Vi–
32
Vi–
32
Vi–
AC input voltage 4
29
N
29
N
29
N
29
N
29
N
29
N
AC input voltage
32
P
32
P
32
P
32
P
32
P
32
P
1 This function is not simultaneously available with option P
3 AM, BM, CM, DM, EM, FM and CMZ, DMZ types
2 Leading pin (pregrounding)
4 LM and LMZ types
Safety and Installation Instructions
Connector Pin Allocation
The connector pin allocation table defines the electrical
potentials and the physical pin positions on the H11 con-
nector. Pin no. 26, the protective earth pin present on all
AM…LM (class I equipment) DC-DC converters is leading,
ensuring that it makes contact with the female connector
first.
32 29 26 23 20 17 14 11 85 2
10015
Fig. 17
View of male H11 connector.
Installation Instructions
The M series DC-DC converters are components, intended
exclusively for inclusion within other equipment by an in-
dustrial assembly operation or by professional installers. In-
stallation must strictly follow the national safety regulations
in compliance with the enclosure, mounting, creepage,
clearance, casualty, markings and segregation require-
ments of the end-use application. See also:
Technical Infor-
mation: Installation and Application.
Connection to the system shall be made via the female con-
nector H11 (see
Accessories). Other installation methods
may not meet the safety requirements.
AM...LM DC-DC converters (class I equipment) are pro-
vided with pin no. 26 (
), which is reliably connected with
their case. For safety reasons it is essential to connect this
pin with the protective earth of the supply system if required
in:
Safety of operator accessible output circuit .
An input fuse is built-in in the connection from pin no. 32
(Vi– or P ) of the unit. Since this fuse is designed to protect
the unit in case of an overcurrent and does not necessarily
cover all customer needs, an external fuse suitable for the
application and in compliance with the local requirements
might be necessary in the wiring to one or both input pins
(no. 29 and/or no. 32).
Important: Whenever the inhibit function is not in use,
pin 2 (i) should be connected to pin 23 (Vo1–) to enable
the output(s).
Do not open the modules, or guarantee will be invali-
dated.
Make sure that there is sufficient air flow possible for con-
vection cooling. This should be verified by measuring the
case temperature when the unit is installed and operated in
the end-use application. The maximum specified case tem-
perature
TC max shall not be exceeded. See also: Thermal
Considerations.
If the end-product is to be UL certified, the temperature of
the main isolation transformer should be evaluated as part
of the end-product investigation.
Protection Degree
Condition: Female connector fitted to the unit.
IP 40: All units, except those with options P, A or K, and
except those with option D or V with potentiometer.
IP 30: All units fitted with options A or K, except those with
option P, and except those with option D or V with
potentiometer.
IP 20: All units fitted with option P, or with option D or V with
potentiometer.
Cleaning Agents
In order to avoid possible damage, any penetration of liq-
uids (e.g. cleaning fluids) is to be prevented, since the
power supplies are not hermetically sealed.
相關(guān)PDF資料
PDF描述
CM1901-9ERV2HF 1-OUTPUT 50 W DC-DC REG PWR SUPPLY MODULE
CM1901-9PV0AH 1-OUTPUT 50 W DC-DC REG PWR SUPPLY MODULE
CM2320-7EPV3H 2-OUTPUT 50 W DC-DC REG PWR SUPPLY MODULE
CM2320-9PF 2-OUTPUT 50 W DC-DC REG PWR SUPPLY MODULE
CM2540-7EPV0F 2-OUTPUT 50 W DC-DC REG PWR SUPPLY MODULE
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
CM1901-7R 功能描述:EURO-CASSETTE 50W 48V RoHS:否 類別:電源 - 外部/內(nèi)部(非板載) >> DC DC Converters 系列:* 標(biāo)準(zhǔn)包裝:1 系列:Quint 類型:隔離 輸入電壓:24V 輸出:24V 輸出數(shù):1 輸出 - 1 @ 電流(最大):24 VDC @ 50A 輸出 - 2 @ 電流(最大):- 輸出 - 3 @ 電流(最大):- 輸出 - 4 @ 電流(最大):- 功率(瓦特):1200W 安裝類型:底座安裝 工作溫度:0°C ~ 40°C 效率:- 封裝/外殼:模塊 尺寸/尺寸:4.33" L x 9.09" W x 6.14" H(110mm x 231mm x 156mm) 包裝:散裝 電源(瓦特)- 最大:1200W 批準(zhǔn):- 其它名稱:277-69722866365-NDQUINT-BAT/24DC/12AH
CM1901-9R 制造商:Power-One 功能描述:ACDC - Bulk
CM1906 制造商:CML 制造商全稱:Chicago Miniature Lamp,inc 功能描述:T-3 1/4 Miniature Bayonet Base
CM19070K 制造商:Arcolectric 功能描述:
CM1908 制造商:CML 制造商全稱:Chicago Miniature Lamp,inc 功能描述:T-3 1/4 Miniature Bayonet Base
主站蜘蛛池模板: 瑞安市| 河曲县| 突泉县| 中西区| 无为县| 湛江市| 漯河市| 盐山县| 阜平县| 南京市| 南通市| 健康| 宝坻区| 汉中市| 永仁县| 凯里市| 永丰县| 沁源县| 个旧市| 大田县| 昭通市| 巴林右旗| 巴青县| 安徽省| 垫江县| 大宁县| 惠安县| 永新县| 安仁县| 湟源县| 南投县| 石家庄市| 五华县| 仁寿县| 廉江市| 浙江省| 宝坻区| 梁河县| 孟州市| 通州市| 旺苍县|