欧美成人免费电影,国产欧美一区二区三区精品酒店,精品国产a毛片,色网在线免费观看

參數資料
型號: CS1001-9EPV3TB1
廠商: POWER-ONE INC
元件分類: 電源模塊
英文描述: 1-OUTPUT DC-DC REG PWR SUPPLY MODULE
封裝: METAL, CASE S02, MODULE
文件頁數: 13/33頁
文件大小: 438K
代理商: CS1001-9EPV3TB1
S Series Data Sheet
100 Watt AC-DC and DC-DC Converters
APR 26, 2006 revised to SEP 25, 2006
Page 20 of 33
www.power-one.com
Table 14: Isolation
Characteristic
Input to
Output to
Unit
case + output(s)
case
output
Electric
Factory test >1 s
2.8
1
1.4
0.14
kVDC
strength
AC test voltage equivalent to factory test
2.0
1.0
0.1
kVAC
test voltage
Insulation resistance at 500 VDC
300
2
300
2
100
M
Ω
1 In accordance with EN 50116 and IEC/EN 60950 subassemblies are pretested with 5.6 kVDC.
2 Tested at 500 VDC.
Isolation
The electric strength test is performed in the factory as routine
test in accordance with EN 50116, IEC/EN 60950 and UL 1950
and should not be repeated in the field. Power-One will not
honor any guarantee claims resulting from electric strength field
tests.
LS-models Operated at Greater than 63 Hz
Above 63 Hz the earth leakage current may exceed 3.5 mA, the
maximum specified in IEC/EN 60950. The built-in Y-caps are
only approved for
≤ 100 Hz. Frequencies greater than 350 Hz
are only permitted for Vi ≤ 200 VAC.
Characteristic
Class I
Unit
LS1000, LS2000
Maximum earth
Permissible according to IEC/EN 60950
3.5
mA
leakage current
Specified value at 264 V, 50 Hz
1.43
Table 13: Leakage Currents for LS-models
Standards and Approvals
The converters are UL recognized according to UL 1950,
CAN/CSA C22.2 No. 950-95, and TV approved to IEC/EN
60950 standards.
The converters correspond to Class I equipment and have been
evaluated for:
Building in,
Basic insulation between input and case based on 250 V and
double or reinforced insulation or an earthed part between
input and output.
The use in a pollution degree 2 environment,
Connecting the input to a primary or secondary circuit which
is subject to a maximum transient rating of 2500 V.
The converters are subject to manufacturing surveillance in
accordance with the above mentioned UL and ISO 9001:2000
standards.
Railway Applications
The S Series converters have been designed according to
the Railway Standards EN50155 and EN50121. All boards
and components are coated with a protective lacquer.
Cleaning Agents
In order to avoid possible damage, any penetration of
cleaning fluids must be prevented, since the power
supplies are not hermetically sealed.
Protection Degree
Condition: Female connector fitted to the converter.
IP 30:
All models except those with option P and option
D,
or V with potentiometer.
IP 20:
All models exhibiting a potentiometer.
相關PDF資料
PDF描述
CS1001-9ERD1B1 1-OUTPUT DC-DC REG PWR SUPPLY MODULE
CS1001-9ERD3 1-OUTPUT DC-DC REG PWR SUPPLY MODULE
CS1001-9PD8B1 1-OUTPUT DC-DC REG PWR SUPPLY MODULE
CS1001-9PDDB1 1-OUTPUT DC-DC REG PWR SUPPLY MODULE
CS1001-9RD2T 1-OUTPUT DC-DC REG PWR SUPPLY MODULE
相關代理商/技術參數
參數描述
CS1001-9ER 制造商:Power-One 功能描述:DCDC - Bulk
CS1001-9ERT 制造商:MELCHER 功能描述: 制造商:MELCHER 功能描述:POWER SUPPLY 制造商:Power-One 功能描述:POWER SUPPLY
CS-100-206 制造商:Benign Industries 功能描述:1/4IN. IN-LINE VALVE
CS-100-210 制造商:Benign Industries 功能描述:1/4IN. NPT MALE
CS-100-223 制造商:Benign Industries 功能描述:ASSEMBLY PLIERS - 1/4IN.
主站蜘蛛池模板: 蒙阴县| 石林| 吉安县| 丹阳市| 瑞丽市| 如皋市| 景宁| 屏东县| 禹城市| 浑源县| 兴业县| 龙岩市| 金昌市| 花莲县| 冀州市| 仁布县| 黑河市| 榆社县| 博白县| 绵阳市| 巫溪县| 天台县| 陆丰市| 西青区| 封丘县| 偃师市| 凤凰县| 桂东县| 延长县| 梅州市| 娱乐| 金沙县| 太原市| 越西县| 栾川县| 虎林市| 南城县| 阿城市| 德江县| 霍山县| 图木舒克市|