參數(shù)資料
型號(hào): CS1001-9RD9B1
廠商: POWER-ONE INC
元件分類: 電源模塊
英文描述: 1-OUTPUT DC-DC REG PWR SUPPLY MODULE
封裝: METAL, CASE S02, MODULE
文件頁(yè)數(shù): 11/33頁(yè)
文件大小: 438K
代理商: CS1001-9RD9B1
Table 12: H15 connector pin allocation
Pin
Connector type H15
No.
AS to LS1000
AS to LS2000
4
Vo1+
Pos. output 1
Vo2+
Pos. output 2
6
Vo1+
Vo2+
8
Vo1–
Neg. output 1
Vo2–
Neg. output 2
10
Vo1–
Vo2–
12
S+
Sense
Vo1+
Pos. output 1
14
S–
Sense
Vo1–
Neg. output 1
16
R
1
Control of
Vo
R
1
Control of
Vo1
18
i
Inhibit
i
Inhibit
20
D
3
Save data
D
3
Safe data
V
3
ACFAIL
22
T
5
Current share
T
5
Current share
24
2
Protective earth
26
Vi+ N
4
Pos. input
Vi+ N
4
Pos. input
28
Neutral line
4
Neutral line
4
30
Vi– L
4
Neg. input
Vi– L
4
Neg. input
32
Phase line
4
Phase line
4
1 Not connected, if option P is fitted.
2 Leading pin (pre-connecting).
3 Option D excludes option V and vice versa. Pin not connected unless
option D or V is fitted.
4 LS models.
5 Not connected, unless option T is fitted.
S Series Data Sheet
100 Watt AC-DC and DC-DC Converters
APR 26, 2006 revised to SEP 25, 2006
Page 19 of 33
www.power-one.com
Safety and Installation Instructions
Connector Pin Allocation
The connector pin allocation table defines the electrical
potentials and the physical pin positions on the H15/H15 S4
connector. Pin no. 24 (protective earth) is a leading pin, ensuring
that it makes contact first.
Installation Instructions
The S Series converters are components, intended exclusively for
inclusion within other equipment by an industrial assembly
operation or by professional installers. Installation must strictly
follow the national safety regulations in compliance with the
enclosure, mounting, creepage, clearance, casualty, markings and
segregation requirements of the end-use application.
Fig. 22
View of converter’s male connector
Connection to the system shall be made via the female connector
H15 (see:
Accessories). Other installation methods may not meet
the safety requirements.
The converters are provided with pin 24 (
), which is reliably
connected with the case. For safety reasons it is essential to
connect this pin to protective earth. See:
Safety of Operator
Accessible Output Circuit.
Input pins 30 and 32 are internally fused. Since this fuse is
designed to protect the converter in case of an overcurrent and
does not necessarily cover all customer needs, an external fuse
suitable for the application and in compliance with the local
requirements might be necessary in the wiring to one or both input
potentials, pins 26 and 28, and/or 30 and 32.
4
32
Type H15
Fixtures for connector
retention clips
(see Accessories)
10090
Important: When the inhibit function is not in use, pin no. 18 (i)
should be connected to pin no. 14 (S–/Vo1–) to enable the output(s).
Do not open the converters, or guarantee will be invalidated.
Due to high current values, some models provide two internally
parallel connected contacts for certain paths (pins 4/6, 8/10, 26/28
and 30/32). It is recommended to connect load and supply to both
female connector pins of each path in order to keep the voltage
drop across the connector pins at an absolute minimum and to
avoid overstress of the connector contacts with currents higher
than 8 A.
Make sure that there is sufficient airflow possible for convection
cooling. This should be verified by measuring the case
temperature when the converter is installed and operated in the
end-use application. The maximum specified case temperature
TCmax shall not be exceeded. See also Thermal Consid-erations.
If the end-product is to be UL certified, the temperature of the main
isolation transformer should be evaluated as part of the end-
product investigation.
Check for hazardous voltages before altering any connections.
Ensure that a converter failure (e.g., by an internal short-circuit)
does not result in a hazardous condition. See also: Safety of
Operator-Accessible Output Circuits.
相關(guān)PDF資料
PDF描述
CS1301-7EPD7B1 1-OUTPUT DC-DC REG PWR SUPPLY MODULE
CS1301-7PD2T 1-OUTPUT DC-DC REG PWR SUPPLY MODULE
CS1301-7PDDT 1-OUTPUT DC-DC REG PWR SUPPLY MODULE
CS1301-9ERD3TB1 1-OUTPUT DC-DC REG PWR SUPPLY MODULE
CS1301-9PD4 1-OUTPUT DC-DC REG PWR SUPPLY MODULE
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
CS-100-206 制造商:Benign Industries 功能描述:1/4IN. IN-LINE VALVE
CS-100-210 制造商:Benign Industries 功能描述:1/4IN. NPT MALE
CS-100-223 制造商:Benign Industries 功能描述:ASSEMBLY PLIERS - 1/4IN.
CS-100-255 制造商:Benign Industries 功能描述:STARTER KIT 1/2IN. BORE
CS-100-257 制造商:Benign Industries 功能描述:HOSE PACK 1/2IN. BORE
主站蜘蛛池模板: 南部县| 瑞丽市| 福建省| 灌云县| 达拉特旗| 鲜城| 青川县| 芮城县| 盐边县| 德保县| 两当县| 博罗县| 乐至县| 门头沟区| 灵台县| 得荣县| 独山县| 乐清市| 亚东县| 常熟市| 长沙县| 玛沁县| 安丘市| 新河县| 霞浦县| 荔波县| 广丰县| 留坝县| 普格县| 云浮市| 吴桥县| 深水埗区| 海阳市| 灵宝市| 重庆市| 邹城市| 霍山县| 招远市| 韶关市| 宁化县| 娄烦县|