代理商: DA101MC-R
KMP_DA100C_C03
Page 1 of 3
Technical enquiries -
email:
mk@murata-ps.com,
tel:
+44 (0)1908 615232
www.murata-ps.com
DA100 Series
Transformers for Digital Audio Data Transmission
For full details go to
www.murata-ps.com/rohs
FEATURES
RoHS compliant
Compatible with leading chip sets
2kVrms isolation
Industry-standard pinout
Surface mount option
UL 94 V-0 package materials
Low profile
Suitable for both 75 & 110Ω circuits
Toroidal construction
Compliant with AES/EBU standards
Fully encapsulated
DESCRIPTION
The Digital Audio Range of transformers is
designed to improve the balance of transmitter
and receiver circuitry in hi-fi equipment,
video games and other applications requiring
high-performance digital audio transmission.
Compliant with AES/EBU recommendations for the
digital audio interface, offering optimised shunt
capacitance between primary and secondary
windings. Capable of operating over the audio
data rate frequency range, providing isolation from
50-60Hz noise.
SELECTION GUIDE
Order Code
T
Primary
Inductance
(10kHz, 50mV)
Max.
Leakage
Inductance
(100kHz, 10mV)
M
P
M
(
T
M
(
Isolation
(Flash tested
for 1 second)
mH
μH
Vμs
dB
dB
Vrms
DA101C
1:1
1.00 - 1.59
0.22
15
46.80
52.10
2000
DA102C
1:1
2.00 - 3.00
0.39
20
40.40
49.70
DA103C
1:1
4.00 - 5.96
0.91
28
36.30
46.40
ORDER CODE DETAILS
Order Code
Package Type
Packaging Type
Quantity
DAXXXC
6 Pin DIL
Tube
50
DAXXXMC
6 Pin SM
Tube
50
DAXXXMC-R
6 Pin SM
Tape & Reel
500
ABSOLUTE MAXIMUM RATINGS
Operating free air temperature range
0°C to 70°C
Storage temperature range
–40°C to 125°C
All specifications typical at T
A
=25°C
TECHNICAL NOTES
ISOLATION
VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Volt-
age’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’
are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed
to provide electrical isolation, to verify the integrity of that
isolation.
All products in this series are 100% production tested at
their stated isolation voltage.
A question commonly asked is, “What is the continuous
voltage that can be applied across the part in normal opera-
tion”
For a part holding no specific agency approvals both input
and output should normally be maintained within SELV limits
i.e. less than 42.4V peak, or 60VDC. The isolation test volt-
age represents a measure of immunity to transient voltages
and the part should never be used as an element of a safety
isolation system. The part could be expected to function cor-
rectly with several hundred volts offset applied continuously
across the isolation barrier; but then the circuitry on both
sides of the barrier must be regarded as operating at an
unsafe voltage and further isolation/insulation systems must
form a barrier between these circuits and any user-acces-
sible circuitry according to safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation
testing of a barrier component can actually degrade
isolation capability, to a lesser or greater degree
depending on materials, construction and environ-
ment. This series has toroidal isolation transformers,
with no additional insulation between primary and
secondary windings of enameled wire. While parts
can be expected to withstand several times the
stated test voltage, the isolation capability does de-
pend on the wire insulation. Any material, including
this enamel (typically polyurethane) is susceptible
to eventual chemical degradation when subject to
very high applied voltages thus implying that the
number of tests should be strictly limited. We there-
fore strongly advise against repeated high voltage
isolation testing, but if it is absolutely required, that
the voltage be reduced by 20% from specified test
voltage.
This consideration equally applies to agency recog-
nized parts rated for better than functional isolation
where the wire enamel insulation is always supple-
mented by a further insulation system of physical
spacing or barriers.
相關PDF資料
PDF描述
DA101C BROADCAST AUDIO TRANSFORMER
DA2319-ALD PULSE TRANSFORMER FOR GATE DRIVE APPLICATION(S)
DA24M 500 W, UNIDIRECTIONAL, 6 ELEMENT, SILICON, TVS DIODE
DAO15S965MTXXXLF 15 CONTACT(S), FEMALE, D SUBMINIATURE CONNECTOR, SOLDER
DAO15S965MXXXLF 15 CONTACT(S), FEMALE, D SUBMINIATURE CONNECTOR, SOLDER
相關代理商/技術參數
參數描述
DA101MR 制造商:CANDD 制造商全稱:C&D Technologies 功能描述:Transformers for Digital Audio Data Transmission
DA101M-R 制造商:Murata Power Solutions 功能描述:Audio Transformer 1:1 2000Vrms Surface Mount
DA101-PB-B 制造商:Carling Technologies 功能描述:D-SERIES TOGGLE SWITCH - Bulk
DA101-PB-B/POLY 制造商:Carling Technologies 功能描述:D-SERIES TOGGLE SWITCH - Bulk
DA101-PB-B-XFO1 制造商:Carling Technologies 功能描述:D-SERIES TOGGLE SWITCH - Bulk
主站蜘蛛池模板: 镇远县| 铜鼓县| 兰州市| 通榆县| 如东县| 常州市| 固安县| 柳州市| 恩平市| 松江区| 岚皋县| 武宁县| 克山县| 河池市| 梨树县| 合山市| 武功县| 芜湖县| 嘉禾县| 曲沃县| 景德镇市| 新河县| 突泉县| 南安市| 福清市| 江陵县| 天柱县| 浠水县| 邛崃市| 米易县| 三明市| 佳木斯市| 通辽市| 加查县| 耒阳市| 白银市| 临夏市| 米脂县| 汉川市| 洛川县| 成武县|