FEATURES
Data Sheet No. BRDB-3500P-1B
ADBD-3500P-1B
MECHANICAL SPECIFICATION
SERIES: DB3500P - DB3510P and ADB3504P - ADB3508P
Tel.: (310) 767-1052
Fax: (310) 767-7958
DIOTEC ELECTRONICS CORP.
18020 Hobart Blvd., Unit B
Gardena, CA 90248
U.S.A
F47
PRV Ratings from 50 to 1000 Volts
Surge overload rating to 400 Amps peak
High efficiency
Heat sink integrally mounted in the molded bridge encapsulation
MECHANICAL DATA
MAXIMUM RATINGS & ELECTRICAL CHARACTERISTICS
Ratings at 25 °C ambient temperature unless otherwise specified. Single phase, half wave, 60Hz, resistive or inductive load. For capacitive loads, derate current by 20%.
T
J
, T
STG
I
O
°C
-55 to +150
Average Forward Rectified Current @ T = 55 C (Note 2)
Peak Forward Surge Current (8.3 mSec single half sine wave
superimposed on rated load)
Junction Operating and Storage Temperature Range
PARAMETER (TEST CONDITIONS)
Maximum DC Blocking Voltage
Maximum Peak Recurrent Reverse Voltage
Working Peak Reverse Voltage
Series Number
V
RWM
V
RRM
V
R (RMS)
V
RM
SYMBOL
ADB
3504P 3506P3508P 3500P3501P 3502P 3504P 3506P 3508P 3510P
ADB
ADB
DB
DB
DB
DB
DB
DB
DB
AMPS
UNITS
VOLTS
1000
400
600
800
50
100
200
400
600
800
RMS Reverse Voltage
280
420
560
35
70
140
280
420
700
560
CONTROLLED
AVALANCHE
NON-CONTROLLED
AVALANCHE
Thermal Energy (Rating for Fusing)
I t
2
35
AMPS
SEC
2
I
FSM
R
θ
JC
R
θ
JL
V
FM
Maximum Forward Voltage (Per Diode) at 17.5 Amps DC
VOLTS
VOLTS
n/a
n/a
Mimimum Avalanche Voltage
Maximum Avalanche Voltage
V
(BR) Min
V
(BR) Max
Maximum Reverse Current at Rated V
RM
@ T = 25 C
A
@T = 100 C
A
o
o
I
RM
Minimum Insulation Breakdown Voltage (Circuit to Case)
V
ISO
Typical Thermal Resistance (on Heat Sink); Junction to Ambient
(Note 3)
450
650
850
900 1100 1300
1.1
1
5
μ
A
2500
o
C/W
1.2
0.8
4.97fbrbd35p
664
400
RATINGS
Suffix "T" indicates FAST-ON TERMINALS
Suffix "W" indicates WIRE LEADS
NOTES: (1) Maximum soldering time and temperature = 10 Sec @ 265 C
(2) Unit Mounted on Metal Chassis.
(3) Mounted on an 11.8 in. x 0.06 in. thick (300mm x 1.5mm thick) copper plate.
2
2
Case: Molded plastic, U/L Flammability Rating 94V-0
Terminals: Round silver plated copper pins or fast-on terminals
Soldering: Per MIL-STD 202 Method 208 guaranteed (Note 1)
Polarity: Marked on side of case
Mounting Position: Any. Through hole for #8 screw.
Max. mounting torque = 20 in-lb.
Weight: Fast-on Terminals - 0.7 Ounces (20.0 Grams)
Wire Leads - 0.55 Ounces (16.0 Grams)
D3
D1
D1
BL
HOLE FOR
#8 SCREW
D2
BL
BH
LT
HOLE FOR
#8SCREW
LD
LL
BH
D1
D2
BL
D1
BL
TopView of
HeatSink
Suffix "P" indicates molded PLASTIC with intergrally mounted Heat Sink
Heat Sink
+
_
AC
AC
UL RECOGNIZED - FILE #E141956
Body
Molded
Body
+
_
AC
AC
+
_
AC
AC
相關(guān)PDF資料
PDF描述
DB3500P
DB3501
DB3501P
DB3502
DB3502P
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
DB35005 制造商:DIOTEC 制造商全稱(chēng):Diotec Semiconductor 功能描述:Three-Phase Si-Bridge Rectifiers
DB35-005 制造商:SEMIKRON 制造商全稱(chēng):Semikron International 功能描述:Three-Phase Si-Bridge Rectifiers
DB35-005_06 制造商:SEMIKRON 制造商全稱(chēng):Semikron International 功能描述:Three-Phase Si-Bridge Rectifiers
DB35-005_07 制造商:DIOTEC 制造商全稱(chēng):Diotec Semiconductor 功能描述:Three-Phase Si-Bridge-Rectifiers
DB3500P 制造商:DEC 制造商全稱(chēng):DEC 功能描述:35 AMP SILICON BRIDGE RECTIFIERS
主站蜘蛛池模板: 湖南省| 曲靖市| 体育| 睢宁县| 吉安县| 河北区| 阿克陶县| 唐山市| 工布江达县| 临汾市| 宁陕县| 金堂县| 康保县| 潞西市| 福州市| 灵台县| 奉化市| 丹凤县| 弋阳县| 岑溪市| 鸡泽县| 佳木斯市| 云龙县| 万盛区| 阜康市| 武邑县| 渑池县| 新郑市| 上杭县| 利津县| 沙洋县| 舟山市| 哈尔滨市| 儋州市| 来安县| 香港 | 昂仁县| 辽源市| 平泉县| 饶平县| 辽阳市|