5
DG181 Series
SUPPLY
I+
DG181, DG182,
DG190, DG191
V
IN
= 5V
-
1.5
-
-
1.5
-
mA
DG184, DG185
-
0.1
-
-
0.1
-
mA
DG187, DG188
-
0.8
-
-
0.8
-
mA
I-
DG181, DG182,
DG190, DG191
-
-5.0
-
-
-5.0
-
mA
DG184, DG185
-
-4.0
-
-
-4.0
-
mA
DG187, DG188
-
-3.0
-
-
-3.0
-
mA
I
L
DG181, DG182,
DG184, DG185,
DG190, DG191
-
4.5
-
-
4.5
-
mA
DG187, DG188
-
3.2
-
-
3.2
-
mA
I
GND
I+
All
-
-2.0
-
-
-2.0
-
mA
DG181, DG182,
DG190, DG191
V
IN
= 0V
-
1.5
-
-
1.5
-
mA
DG184, DG185
-
3.0
-
-
3.0
-
mA
DG187, DG188
-
0.8
-
-
0.8
-
mA
I-
DG181, DG182,
DG190, DG191
-
-5.0
-
-
-5.0
-
mA
DG184, DG185
-
-5.5
-
-
-5.5
-
mA
DG187, DG188
-
-3.0
-
-
-3.0
-
mA
I
L
DG181, DG182,
DG184, DG185,
DG190, DG191
-
4.5
-
-
4.5
-
mA
DG187, DG188
-
3.2
-
-
3.2
-
mA
I
GND
NOTE:
1. See Switching State Diagrams for V
IN
“ON” and V
IN
“OFF” Test Conditions.
All
-
-2.0
-
-
-2.0
-
mA
Electrical Specifications
Maximum Resistances (R
DS(ON)
MAX)
DEVICE
NUMBER
TEST CONDITIONS
(NOTE 1)
V+ = 15V, V- = -15V, V
L
= 5V
V
D
= -7.5V
V
D
= -10V
V
D
= -7.5V
V
D
= -10V
V
D
= -7.5V
V
D
= -10V
V
D
= -7.5V
V
D
= -10V
MILITARY
TEMPERATURE
-55
o
C
+25
o
C
INDUSTRIAL
TEMPERATURE
-20
o
C
+25
o
C
UNITS
+125
o
C
+85
o
C
DG181
I
S
= -10mA, V
IN
= “ON”
30
30
60
50
50
75
DG182
75
75
100
100
100
150
DG184
30
30
60
50
50
75
DG185
75
75
150
100
100
150
DG187
30
30
60
50
50
75
DG188
75
75
150
100
100
150
DG190
30
30
60
50
50
75
DG191
NOTES:
1. See Switching State Diagrams for V
IN
“ON” and V
IN
“OFF” Test Conditions.
2. Normally the minimum signal handling capability of the DG181 thru DG191 family is 20V peak to peak for the 75
switches and 15V peak-
to-peak for the 30
(refer I
D
and I
S
tests above).
3. For other Analog Signals, the following guidelines can be used: proper switch turn-off requires that V-
≤
V
ANALOG
(peak) - V
P
where V
P
=
7.5V for the 80
switches and V
P
= 5.0V for 75
switches e.g., - 10V minimum (-peak) analog signal and a 75
switch (V
P
= 5V), requires
that V-
≤
-10V -5V = -15V.
75
75
150
100
100
150
Electrical Specifications
V+ = +15V, V- = -15V, V
L
= 5V, Unless Otherwise Specified
(Continued)
PARAMETER
DEVICE
NUMBER
(NOTE 1)
TEST CONDITIONS
A SERIES
+25
o
C
B SERIES
+25
o
C
UNITS
-55
o
C
+125
o
C
-20
o
C
+85
o
C