DG381A/384A/387A/390A
Siliconix
S-52880—Rev. C, 28-Apr-97
5
Specifications
a
Test Conditions
Unless Otherwise Specified
V+ = 15 V, V– = –15 V
V
IN
= 0.8 V or 4 V
f
A Suffix
–55 to 125 C
Min
d
B, C Suffix
0 to 70 C
–25 to 85 C
Min
d
Parameter
Symbol
Temp
b
Typ
c
Max
d
Max
d
Unit
Analog Switch
Analog Signal Range
e
V
ANALOG
Full
–15
15
–15
15
V
Drain-Source
On-Resistance
r
DS(on)
V
D
=
10 V, I
S
= –10 mA
Room
Full
30
50
75
50
75
Source Off
Leakage Current
I
S(off)
V
S
=
14 V, V
D
=
14 V
Room
Hot
0.1
–1
–100
1
100
–5
–100
5
100
Drain Off
Leakage Current
I
D(off)
V
S
=
14 V, V
D
=
14 V
Room
Hot
0.1
–1
–100
1
100
–5
–100
5
100
nA
Drain On
Leakage Current
I
D(on)
V
D
= V
S
=
14 V
Room
Hot
0.1
–11
–100
1
100
–5
–100
5
100
Digital Control
Inp
V l
Input Voltage High
Hi h
I
INH
V
IN
= 5 V
Room
Full
–0.001
–1
–1
–1
V
IN
= 15 V
Room
Full
0.001
1
1
1
A
Input Current with
Input Voltage Low
I
INL
V
IN
= 0 V
Room
Full
–0.001
–1
–1
–1
Dynamic Characteristics
Turn-On Time
t
ON
t
OFF
t
OPEN
Q
See Figure 2
Room
150
300
Turn-Off Time
Room
130
250
ns
Break-Before-Make Time
See Figure 3
Room
50
Charge Injection
C
L
= 0.01 F, R
gen
= 0 V
gen
= 0 V
Room
10
pC
Source-Off Capacitance
C
S(off)
C
D(off)
C
D(on)
Room
14
Drain-Off Capacitance
f = 1 MHz; V
S
, V
D
= 0 V
Room
14
Channel-On Capacitance
Room
40
pF
Input Capacitance
C
IN
f = 1 MHz
V
IN
= 0 V
V
IN
= 15 V
Room
6
Room
7
Off-Isolation
OIRR
= 0 V R
V
IN
= 0 V, R
L
= 1 k
V
S
= 1 V
rms
, f = 500 kHz
Room
62
Crosstalk
(Channel-to-Channel)
X
TALK
Room
74
dB
Power Supplies
Positive Supply Current
I+
V
= 4 V (
(All O h
(All Others = 0)
Room
Full
0.23
0.5
1.0
1
mA
Negative Supply Current
I–
IN
p )
Room
Full
–0.001
–10
–100
–100
Positive Supply Current
I+
= 0 8 V (All Inputs)
V
IN
= 0.8 V (All Inputs)
Room
Full
0.001
10
100
100
A
Negative Supply Current
I–
Room
Full
–0.001
–10
–100
–100
Notes:
a.
b.
c.
d.
e.
f.
Refer to PROCESS OPTION FLOWCHART.
Room = 25 C, Full = as determined by the operating temperature suffix.
Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
Guaranteed by design, not subject to production test.
V
IN