rev 06.14.05
Technical Support: (888) 41ASTEC or (407) 241-2752
Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662
190
Special Features
60 Watts
DPS50 Series
Electrical Specs
CE Mark EMC & LVD
Universal AC input
Fully regulated output
Overload and short circuit protection
Internal remote sense
Constant voltage
High efficiency
High MTBF
IEC320 AC receptacle, 3 pin (type C14)
Built in EMI filter (CISPR 22 Class B)
LED power good indicator
Input power <74 watts
Complies with EN61000-3-2
Input
Input range
90 - 264 VAC (wide range),
127 - 300 VDC
47 - 440 Hz
<50A @ 230 VAC, cold start @ 25C
<2.0A rms @ 115 VAC; <1A @ 230 VAC
>80% @ full load typical, @115VAC
FCC Part 15, Subpart B Class B &
EN55022 (CISPR 22) Class B
Frequency
Inrush current
Input current
Efficiency
EMI/RFI
Safety ground
leakage current
<0.5mA @ 50/60 Hz, 264 VAC input
Output
Maximum Power (Po)
Hold-up time
Overvoltage protection 20% - 45% above nominal output
maximum.
Latching type, recycle AC to reset.
Overload protection
Output short circuit protection
auto recover. Overload protected
@ 120 - 150% above maximum rating.
Cable/connector
DC cable with 2.5 mm center plug
barrel type
DC plug center +v
DC plug outer -v
60W (DPS52, 30W)
10 ms. typical at full load @ 115VAC
Operating temperature: 0°C to +40°C
ambient. Derate each output as 2.5% per
degree from 40° to 60°C. -20°C start up.
Storage temperature: -40°C to +85°C
Electromagnetic susceptability
designed to meet EN61000-4;
-2, -3, -4, -5, -6, -8, -11, level 3
Humidity: Operating; non-condensing; 10%
to 95% RH
Vibration: Three orthogonal axes, 3 sweeps
per axe at 1 oct/min. 2G peak 8 Hz to 500 Hz,
operational
MTBF demonstrated: >550,000 hours at full
load and 25°C ambient conditions
UL
CSA
NEMKO
VDE
CE
CB
CCC
UL 60950-1
CSA-C22.2 No. 60950-1
IEC/EN60950-1
EN60950-1
EMC & LVD
Certificate and report
GB4943
Environmental
Safety
Total Power:
Input Voltage:
127 - 300 VDC, 90 - 264 VAC
# of Outputs:
Single
30 - 60 Watts