欧美成人免费电影,国产欧美一区二区三区精品酒店,精品国产a毛片,色网在线免费观看

參數資料
型號: FARM1CN3
廠商: Vicor Corporation
元件分類: DC/DC變換器
英文描述: FARM Filter/ Autoranging Rectifier Module
中文描述: 農場過濾器/自動調節整流模塊
文件頁數: 7/12頁
文件大?。?/td> 314K
代理商: FARM1CN3
Set your site on VICOR at www.vicorpower.com
PRELIMINARY
Vicor Corp.
Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
FARM, Filter/Autoranging Rectifier Module
Rev. 4.7
Page 7 of 12
Bus-OK (BOK) Pin.
(see Fig. 11)
The Bus-OK pin is
intended to provide early-warning power fail information and
is also referenced to the negative output pin.
Caution: There is no input to output isolation in the FARM.
It is
necessary to monitor Bus-OK via an optoisolator if it is to be
used on the secondary (output) side of the converters. A line
isolation transformation should be used when performing scope
measurements. Scope probes should never be applied
simultaneously to the input and output as this will destroy the unit.
Filter.
(see Fig. 12)
An integral input filter consists of a
common mode choke and Y rated capacitors (line-ground)
plus two X rated capacitors (line-line). This filter
configuration provides common mode and differential mode
insertion loss in the frequency range between 100kHz and
30MHz as illustrated in Figure 6.
Hold-up Capacitors.
Hold-up capacitor values should be
determined according to output bus voltage ripple, power fail
hold-up time, and ride-through time
(see Fig. 13)
.
Many applications require the power supply to maintain
output regulation during a momentary power failure of
specified duration, i.e., the converters must hold-up or ride
through such an event while maintaining undisturbed output
voltage regulation. Similarly, many of these same systems
require notification of an impending power failure in order to
allow time to perform an orderly shutdown.
The energy stored on a capacitor which has been charged to
voltage V is:
ε
= 1/2(CV
2
) (1)
ε
= stored energy
C = capacitance
V = voltage across the capacitor
Where:
Energy is given up by the capacitors as they are discharged
by the converters. The energy expended
(the power-time product) is:
ε
= P
t = C(V
12
–V
22
) / 2 (2)
Where: P = operating power
t = discharge interval
V
1
= capacitor voltage at the beginning
of
t
V
2
= capacitor voltage at the end of
t
Rearranging Equation 2 to solve for the required
capacitance:
C = 2P
t / (V
12
–V
22
) (3)
Application Note (continued)
+In
PC (Gate In)
Vicor DC-DC
Converter
PR (Gate Out)
–In
N
EMI GND
N/C
L
+
B OK
ST
EN
150k
15Vdc
cMicro-
Figure 10
—Enable (EN) function
+In
PC (Gate In)
Vicor DC-DC
Converter
PR (Gate Out)
–In
N
EMI GND
N/C
L
+
B OK
ST
EN
cMicro-
15 Vdc
27k
+5 Vdc
Secondary
referenced
Optocoupler DI pkg. 26106
Optocoupler SM pkg. 26109
Figure 11
—Bus OK (BOK) isolated power status indicator
4.7nF
L1
4.7nF
N
EMI GND
N/C
L
+
B OK
ST
EN
.47
μ
F
.099
μ
F
330
μ
H
Figure 12
—Internal filter
相關PDF資料
PDF描述
FARM1CS1 FARM Filter/ Autoranging Rectifier Module
FARM1CS2 FARM Filter/ Autoranging Rectifier Module
FARM1CS3 FARM Filter/ Autoranging Rectifier Module
FARM1T11 FARM Filter/ Autoranging Rectifier Module
FARM1T12 FARM Filter/ Autoranging Rectifier Module
相關代理商/技術參數
參數描述
FARM1CS1 制造商:POWERBOX 制造商全稱:Powerbox 功能描述:AUTORANGING AC INPUT WITH FILTER
FARM1CS2 制造商:POWERBOX 制造商全稱:Powerbox 功能描述:AUTORANGING AC INPUT WITH FILTER
FARM1CS3 制造商:POWERBOX 制造商全稱:Powerbox 功能描述:AUTORANGING AC INPUT WITH FILTER
FARM1E11 制造商:POWERBOX 制造商全稱:Powerbox 功能描述:AUTORANGING AC INPUT WITH FILTER
FARM1E12 制造商:POWERBOX 制造商全稱:Powerbox 功能描述:AUTORANGING AC INPUT WITH FILTER