FM75
PRODUCT SPECIFICATION
10
REV. 1.0.5 10/2/03
Serial Data Bus Operation
General Operation
Writing to and reading from the FM75 registers is accom-
plished via the SMBus-compatible two-wire serial interface.
SMBus protocol requires that one device on the bus initiates
and controls all read and write operations. This device is
called the “master” device. The master device also generates
the SCL signal which is the clock signal for all other devices
on the bus. All other devices on the bus are called “slave”
devices. The FM75 is a slave device. Both the master and
slave devices can send and receive data on the bus.
During SMBus operations, one data bit is transmitted per
clock cycle. All SMBus operations follow a repeating nine
clock-cycle pattern that consists of eight bits (one byte) of
transmitted data followed by an acknowledge (ACK) or not
acknowledge (NACK) from the receiving device. Note that
there are no unused clock cycles during any operation—
therefore there must be no breaks in the stream of data and
ACKs/NACKs during data transfers. Conversely having too
few clock cycles can lead to incorrect operation if an
inadvertent 8-bit read from a 16-bit register occurs.
For most operations, SMBus protocol requires the SDA line
to remain stable (unmoving) whenever SCL is high—i.e.,
transitions on the SDA line can only occur when SCL is low.
The exceptions to this rule are when the master device issues
a start or stop signal. Note that the slave device cannot issue
a start or stop condition.
The following are definitions for some general SMBus
terms:
Start Condition:
This condition occurs when the SDA line
transitions from high to low while SCL is high. The master
device uses this condition to indicate that a data transfer is
about to begin.
Stop Condition:
This condition occurs when the SDA line
transitions from low to high while SCL is high. The master
device uses this condition to signal the end of a data transfer.
Acknowledge
and
Not Acknowledge:
When data is trans-
ferred to the slave device it sends an acknowledge (ACK)
after receiving every byte of data. A master device sends an
acknowledge (ACK) following only the first byte read from a
2-byte register. The receiving device sends an ACK by
pulling SDA low for one clock. Following the last byte,
a master device sends a “not acknowledge” (NACK)
followed by a stop condition. A NACK is indicated by
leaving SDA high during the clock after the last byte.
Slave Address
Each slave device on the bus has a unique 7-bit address so
the master can identify which device is being read from or
written to.
The FM75 address is as follows:
The four MSBs of the FM75 address are hardwired to 1001.
The three LSBs are user configurable by tying the A0, A1
and A2 pins to either V
D
D or ground. This provides eight
different FM75 addresses, which allows up to eight FM75s
to be connected to the same bus.
Writing To and Reading From the FM75
All read and write operations must begin with a start signal
generated by the master device. After the start condition, the
master device must immediately send a slave address (7 bits)
followed by a read/write bit. If the slave address matches the
address of the FM75, the FM75 sends an ACK after
receiving the read/write bit by pulling the SDA line low
for one clock. See Figure 8 through Figure 13 for timing
diagrams for all FM75 operations.
Setting the Pointer
For all operations the pointer stored in the Command
Register must be pointing to the register (Temperature,
Configuration, T
OS
or T
HYST
) that is going to be written to
or read from. To change the pointer value in the Command
Register, the read/write bit following the address must be 0.
This indicates that the master will now write new informa-
tion into the Command Register.
After the FM75 sends an ACK in response to receiving the
address and read/write bit, the master device must transmit
an appropriate 8-bit pointer value as explained in the
Registers section of this data sheet. The FM75 will send an
ACK after receiving the new pointer data.
The pointer set operation is illustrated in Figure 8. Anytime a
pointer set is performed, it must be immediately followed by
a read or write operation. Note that the 6 MSBs of the
pointer value must be zero. If the 6 MSBs are not zero, the
FM75 will not send an ACK and will internally terminate the
operation. Also recall that the Command Register retains the
current pointer value between operations. Therefore, once a
register is being pointed to, subsequent read operations do
not require a pointer set cycle. Write operations always
require the pointer be reset.
1
0
0
1
A1
A2
A0
相關PDF資料
PDF描述
FM75M8X Low Voltage 2-Wire Digital Temperature Sensor with Thermal Alarm
FM803MS3X 3-Pin レC Supervisor Device
FM803RP3X 3-Pin レC Supervisor Device
FM803SP3X 3-Pin レC Supervisor Device
FM803TS3X 3-Pin レC Supervisor Device
相關代理商/技術參數
參數描述
FM75_06 制造商:FAIRCHILD 制造商全稱:Fairchild Semiconductor 功能描述:Low-Voltage Two-Wire Digital Temperature Sensor with Thermal Alarm
FM751V-FL 制造商:FORMOSA 制造商全稱:Formosa MS 功能描述:30mA Surface Mount Small Signal Schottky Diode- 40V
FM751V-NL 制造商:FORMOSA 制造商全稱:Formosa MS 功能描述:30mA Surface Mount Small Signal Schottky Diode- 40V
FM754 制造商:BACO Controls Inc 功能描述:
FM75M8 功能描述:板上安裝溫度傳感器 Low Voltage Digital I2C comp Temp Sensor RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關閉: 安裝風格: 封裝 / 箱體: 設備功能:Temperature and Humidity Sensor
主站蜘蛛池模板: 广德县| 广平县| 积石山| 怀远县| 青神县| 二连浩特市| 宜都市| 信阳市| 上栗县| 乌苏市| 深圳市| 兰溪市| 水富县| 兴宁市| 牙克石市| 托克托县| 阿图什市| 茌平县| 章丘市| 呼图壁县| 资兴市| 渭南市| 家居| 泰和县| 安龙县| 沧州市| 通榆县| 绥宁县| 郁南县| 四川省| 德格县| 巴青县| 马山县| 项城市| 宁城县| 临漳县| 壤塘县| 樟树市| 玉屏| 内江市| 辽中县|