- 454 -
FRAF801G
THRU
FRAF807G
Isolation 8.0 AMPS. Glass Passivated Fast Recovery Rectifiers
Voltage Range
50 to 1000 Volts
Current
8.0 Amperes
ITO-220AC
Features
Low forward voltage drop
High current capability
High reliability
High surge current capability
Mechanical Data
Cases: ITO-220AC molded plastic
Epoxy: UL 94V-0 rate flame retardant
Terminals: Leads solderable per
MIL-STD-202, Method 208 guaranteed
Polarity: As marked
High temperature soldering guaranteed:
260
℃
/10 seconds 0.25”,(6.35mm) from case.
Mounting position: Any
Weight: 2.24 grams
Mounting torque: 5 in – 1bs. max.
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25
℃
ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
Type Number
Symbol
FRAF
801G
50
35
50
FRAF
802G
100
70
100
FRAF
803G
200
140
200
FRAF
804G
400
280
400
FRAF
805G
600
420
600
FRAF
806G
800 1000
560
800 1000
FRAF
807G
Units
Maximum Recurrent Peak Reverse Voltage
V
RRM
V
RMS
V
DC
V
V
V
Maximum RMS Voltage
700
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
@T
C
= 55
℃
Peak Forward Surge Current, 8.3 ms Single Half
Sine-wave Superimposed on Rated Load (JEDEC
method )
Maximum Instantaneous Forward Voltage @ 8.0A
I
(AV)
8.0
A
I
FSM
150
A
V
F
1.3
5.0
100
V
uA
uA
nS
pF
℃
/
W
℃
Maximum DC Reverse Current @ T
C
=25
℃
at Rated DC Blocking Voltage @ T
C
=125
℃
Maximum Reverse Recovery Time ( Note 2 )
Typical Junction Capacitance ( Note 1 ) T
J
=25
℃
I
R
Trr
Cj
R
θ
JC
T
J
,T
STG
150
250
500
60
5.0
Typical Thermal Resistance (Note 3)
Operating and Storage Temperature Range
Notes: 1. Measured at 1 MHz and Applied Reverse Voltage of 4..0 Volts D.C.
2. Reverse Recovery Test Conditions: I
=0.5A, I
=1.0A, I
=0.25A
3. Thermal Resistance from Junction to Case, with Heatsink size 2” x 3” x 0.25” Al-Plate
-65 to +150