- 324 -
HT11G
THRU
HT18G
1.0 AMP. Glass Passivated High Efficient Rectifiers
Voltage Range
50 to 1000 Volts
Current
1.0 Ampere
TS-1
Features
Low forward voltage drop
High current capability
High reliability
High surge current capability
Mechanical Data
Case: Molded plastic TS-1
Epoxy: UL 94V-O rate flame retardant
Lead: Axial leads, solderable per MIL-STD-
202, Method 208 guaranteed
Polarity: Color band denotes cathode end
High temperature soldering guaranteed:
260
o
C/10 seconds/.375”,(9.5mm) lead
lengths at 5 lbs., (2.3kg) tension
Mounting position: Any
Weight: 0.20 gram
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25
℃
ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
Type Number
Symbol HT
11G
50 100 200 300 400 600 800 1000
35
70 140 210 280 420 560 700
50 100 200 300 400 600 800 1000
HT
12G
HT
13G
HT
14G
HT
15G
HT
16G
HT
17G
HT
18G
Units
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
V
RRM
V
RMS
V
DC
V
V
V
Maximum DC Blocking Voltage
Maximum Average Forward Rectified
Current .375 (9.5mm) Lead Length
@T
A
= 55
℃
Peak Forward Surge Current, 8.3 ms Single
Half Sine-wave Superimposed on Rated
Load (JEDEC method )
Maximum Instantaneous Forward Voltage
@ 1.0A
Maximum DC Reverse Current
@ T
A
=25
℃
at Rated DC Blocking Voltage
@ T
A
=125
℃
Maximum Reverse Recovery Time (Note 1)
Typical Junction Capacitance (Note 2)
Typical Thermal Resistance (Note 3)
I
(AV)
1.0
A
I
FSM
30
A
V
F
1.0
1.3
1.7
V
I
R
5.0
150
uA
uA
nS
pF
℃
/W
℃
℃
Trr
Cj
R
θ
JA
T
J
T
STG
50
15
75
10
95
Operating Temperature Range
-65 to +150
-65 to +150
Storage Temperature Range
Notes: 1.
Reverse Recovery Test Conditions: I
F
=0.5A, I
R
=1.0A, I
RR
=0.25A
2. Measured at 1 MHz and Applied Reverse Voltage of 4.0 V D.C.
3. Mount on cu-Pad Size 5mm x 5mm on PCB.