LA76818A
No.8047-28/44
Deflection Block Test Conditions
Input signal
Symbol
Test point
Input signal
Test method
Bus conditions
Horizontal free-running
frequency
fH
27
Y IN:
No signal
Connect a frequency counter to the output of pin
27 (H out) and measure the horizontal free-running
frequency.
Horizontal pull-in range
fH PULL
42
YIN:
Horizontal/
vertical sync
signal
PAL
Using an oscilloscope, monitor the horizontal sync
signal which is input to the Y IN (pin 42) and the pin
27 output (H out) and vary the horizontal signal
frequency to measure the pull-in range.
Horizontal output
pulse length
Hduty
27
Y IN:
Horizontal/
vertical sync
signal
PAL
Measure the voltage for the pin 27 horizontal
output pulse’s low-level period.
Horizontal output pulse
saturation voltage
V Hsat
27
Y IN:
Horizontal/
vertical sync
signal
PAL
Measure the voltage for the pin 27 horizontal
output pulse’s low-level period.
50
(PAL)
Vertical
free-running
period
60
(NTSC)
VFR50
VFR60
23
Y IN:
No signal
Measure the vertical output period T at pin 23
T
×15.625kHz (PAL)
T
×15.734kHz (NTSC)
CDMODE: 001
(PAL)
CDMODE: 002
(NTSC)
PAL
Horizontal
output pulse
NTSC)
HPHCEN
(PAL)
(NTSC)
27
42
Y IN:
Horizontal/
vertical sync
signal
PAL
NTSC
Measure the delay time from to the rise of the pin
27 horizontal output pulse to the fall of the Y IN
horizontal sync signal.
Horizontal position
adjustment range
HPHrange
27
42
Y IN:
Horizontal/
vertical sync
signal
PAL
With H PHASE: 0 and 31, measure the delay time
from the rise of the pin 27 horizontal output pulse
to the fall of the Y IN horizontal sync signal and
calculate the difference from H PHCEN.
H PHASE: 00000
H PHASE: 11111
Continued on next page.
Measuring
HPHCEN
20IRE
2.5V
Horizontal output
T
2.5V
Vertical output
HPHCEN
20IRE
2.5V
Horizontal output