欧美成人免费电影,国产欧美一区二区三区精品酒店,精品国产a毛片,色网在线免费观看

參數(shù)資料
型號(hào): LC72705E
元件分類(lèi): 消費(fèi)家電
英文描述: SPECIALTY CONSUMER CIRCUIT, PQFP44
封裝: QFP-44
文件頁(yè)數(shù): 12/14頁(yè)
文件大小: 165K
代理商: LC72705E
Frame synchronization error protection count
This IC detects the four unique BIC inflection points that exist in a single frame, and increments or decrements the
protection counter depending on whether or not the IC internal frame synchronization counter matches. The data values
are set in the same way as those for the block synchronization protection count are set, namely data in which 1 has been
subtracted from the desired protection count must be transferred. The frame synchronization default values are 8 for
forward protection and 2 for backward protection.
Control registers
These registers are used to set the IC operating mode. These are described later.
Notes
— The address bits DI12 to DI15 are ignored.
— Addresses other than those listed above (for example location 0110) are special addresses used for test mode and
other special IC functions. Do not set these locations.
— The default values are the values reloaded into the internal registers when a reset signal (RST) is received. These
values are the recommended values for normal operation, and normally do not need to be modified. If only the
default values are used, there is no need to provide data transfer routines in the external CPU or microcontroller.
Layer 4 CRC Check Circuit
This is a function provided for data group error detection, i.e. layer 4 CRC. After the stipulated number of bytes of data
group data and a 16-bit CRC error check word are transferred, the CRC4 pin outputs a high level if there were no errors.
The CRC4 pin outputs a high level if all the bits in the IC internal CRC check register were 0. When using this function
to perform the layer 4 CRC check, the IC internal CRC check register must be initialized before a single data group data
unit is transferred. This register is initialized by sending bit 7 of the control register. Note that since this flag is not
automatically reset to 0, the application must return it to 0 before transferring layer 4 CRC check data. If there were no
errors in any of the received data groups, the CRC register will always be all zeros after the CRC check of a single data
group. Therefore, the above control register initialization will not be necessary as long as there are no errors in the layer 4
CRC. The data length of the transferred data group data is in units of 8 bits. Also note that while there is no upper limit
on the amount of data transferred in a single operation, data transfers may also be divided into multiple transfer
operations.
No. 5744-7/14
LC72705E
Note: *Both forward and backward protection counts are 3.
Figure 1 Block Synchronization Protection Operation (forward
→ backward → forward)
Received data
Synchronization
counter BIC position
Reset
相關(guān)PDF資料
PDF描述
LC72706E SPECIALTY CONSUMER CIRCUIT, PQFP44
LC72707E SPECIALTY CONSUMER CIRCUIT, PQFP44
LC72708E SPECIALTY CONSUMER CIRCUIT, PQFP44
LC72708E SPECIALTY CONSUMER CIRCUIT, PQFP44
LC72709E SPECIALTY CONSUMER CIRCUIT, PQFP44
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
LC72706 制造商:SANYO 制造商全稱(chēng):Sanyo Semicon Device 功能描述:FM Multiplex Receiver IC Supporting All Worldwide Standards
LC72706E 制造商:SANYO 制造商全稱(chēng):Sanyo Semicon Device 功能描述:FM Multiplex Receiver IC Supporting All Worldwide Standards
LC72707 制造商:SANYO 制造商全稱(chēng):Sanyo Semicon Device 功能描述:FM Multiplex Receiver IC Supporting All Worldwide Standards
LC72707E 制造商:SANYO 制造商全稱(chēng):Sanyo Semicon Device 功能描述:FM Multiplex Receiver IC Supporting All Worldwide Standards
LC72708 制造商:SANYO 制造商全稱(chēng):Sanyo Semicon Device 功能描述:FM Multiplex Broadcast Reception IC for Mobile VICS Systems
主站蜘蛛池模板: 兰州市| 普兰店市| 高密市| 迁西县| 孟州市| 三河市| 馆陶县| 都匀市| 高平市| 通江县| 乐安县| 明星| 二连浩特市| 菏泽市| 揭东县| 武安市| 临泉县| 巴青县| 梓潼县| 彭州市| 井研县| 湛江市| 曲水县| 达孜县| 鸡西市| 三江| 漳平市| 大厂| 谢通门县| 肇东市| 溧阳市| 龙泉市| 平昌县| 金门县| 维西| 桑植县| 长阳| 五指山市| 华容县| 吉首市| 高密市|