欧美成人免费电影,国产欧美一区二区三区精品酒店,精品国产a毛片,色网在线免费观看

參數資料
型號: MAX6695YAUB+
廠商: Maxim Integrated
文件頁數: 13/19頁
文件大小: 293K
描述: IC SENSOR TEMP SMBUS 10-UMAX
產品變化通告: Product Discontinuation 13/Jun/2011
標準包裝: 50
功能: 溫度監控系統(傳感器)
傳感器類型: 內部和外部
感應溫度: -40°C ~ 125°C
精確度: ±3°C(最小值)
拓撲: ADC,多路復用器,寄存器庫
輸出類型: I²C?/SMBus?
輸出警報:
輸出風扇:
電源電壓: 3 V ~ 3.6 V
工作溫度: -40°C ~ 125°C
安裝類型: 表面貼裝
封裝/外殼: 10-TFSOP,10-MSOP(0.118",3.00mm 寬)
供應商設備封裝: 10-uMAX
包裝: 管件
begun, after which the device returns to standby mode.
If a conversion is in progress when a one-shot com-
mand is received, the command is ignored. If a one-
shot command is received in autoconvert mode
(RUN/STOP bit = 0) between conversions, a new con-
version begins, the conversion rate timer is reset, and
the next automatic conversion takes place after a full
delay elapses.
Fault Queue Function
To avoid false triggering of the MAX6695/MAX6696 in
noisy environments, a fault queue is provided, which
can be enabled by setting bit 5 (configuration register)
to 1. Four channel 1 fault or two channel 2 fault events
must occur consecutively before the fault output (OT2)
becomes active. Any reading that breaks the sequence
resets the fault queue counter. If there are three over-
limit readings followed by a within-limit reading, the
remote channel 1 fault queue counter is reset.
Configuration Byte Functions
The configuration byte register (Table 6) is a read-write
register with several functions. Bit 7 is used to mask
(disable) ALERT interrupts. Bit 6 puts the device into
software standby mode (STOP) or autonomous (RUN)
mode. Bit 5, when 1, enables the Fault Queue. Bit 4 is
reserved. Bit 3 is used to select either remote channel 1
or remote channel 2 for reading temperature data or for
setting or reading temperature limits. Bit 2 disables the
SMBus timeout, as well as the Alert Response. Bit 1
masks ALERT interrupt due to channel 2 when high. Bit
0 masks ALERT interrupt due to channel 1 when high.
Status Byte Functions
The status registers (Tables 7 and 8) indicate which (if
any) temperature thresholds have been exceeded and
if there is an open-circuit fault detected with the exter-
nal sense junctions. Status register 1 also indicates
whether the ADC is converting. After POR, the normal
state of the registers bits is zero (except bit 7 of status
register 1), assuming no alert or overtemperature con-
ditions are present. Bits 0 through 6 of status register 1
and bits 1 through 7 of status register 2 are cleared by
any successful read of the status registers, unless the
fault persists. The ALERT output follows the status flag
bit. Both are cleared when successfully read, but if the
condition still exists, they reassert at the end of the next
conversion.
The bits indicating OT1 and OT2 are cleared only on
reading status even if the fault conditions still exist.
Reading the status byte does not clear the OT1 and
OT2 outputs. One way to eliminate the fault condition is
for the measured temperature to drop below the tem-
perature threshold minus the hysteresis value. Another
way to eliminate the fault condition is by writing new
values for the RWO2E, RWO2I, RWO1E, RWO1I, or
HYST registers so that a fault condition is no longer
present.
When autoconverting, if the T
HIGH
and T
LOW
limits are
close together, it is possible for both high-temp and
low-temp status bits to be set, depending on the
amount of time between Status Read operations. In
these circumstances, it is best not to rely on the status
bits to indicate reversals in long-term temperature
changes. Instead, use a current temperature reading to
establish the trend direction.
Dual Remote/Local Temperature Sensors with
SMBus Serial Interface
______________________________________________________________________________________   13
BIT
NAME
POR
STATE
FUNCTION
7(MSB)
MASK1
0
Mask ALERT interrupts when 1.
6
RUN/STOP
0
Standby mode control bit. If 1, immediately stops converting and enters
standby mode. If zero, it converts in either one-shot or timer mode.
5
Fault Queue
0
Fault queue enables when 1. When set to 1, four consecutive faults must occur
before OT2 output is asserted.
4
RFU
0
Reserved.
3
Remote 2 Select
0
0: Read/write remote 1 temperature and set-point values.
1: Read/write remote 2 temperature and set-point values.
2
SMB Timeout Disable
0
When set to 1, it disables the SMBus timeout, as well as the alert response.
1
MASK Alert Channel 2
0
When set to 1, it masks ALERT interrupt due to channel 2.
0
MASK Alert Channel 1
0
When set to 1, it masks ALERT interrupt due to channel 1.
Table 6. Configuration Byte Functions
相關PDF資料
PDF描述
MAX6697UP38+ IC TEMP MON 7CH PREC 20TSSOP
MAX6698UE99+ IC TEMP MONITOR 7CH 16-TSSOP
MAX6699EE34+ IC TEMP MONITOR 5CH 16-QSOP
MAX7500MTA+T IC TEMP SENSOR DGTL 8TDFN
MAX786CAI IC REG QD BCK/LINEAR SYNC 28SSOP
相關代理商/技術參數
參數描述
MAX6695YAUB+ 功能描述:板上安裝溫度傳感器 Remote/Local Temperature Sensor RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關閉: 安裝風格: 封裝 / 箱體: 設備功能:Temperature and Humidity Sensor
MAX6695YAUB+T 功能描述:板上安裝溫度傳感器 Remote/Local Temperature Sensor RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關閉: 安裝風格: 封裝 / 箱體: 設備功能:Temperature and Humidity Sensor
MAX6696AEE 功能描述:板上安裝溫度傳感器 RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關閉: 安裝風格: 封裝 / 箱體: 設備功能:Temperature and Humidity Sensor
MAX6696AEE+ 功能描述:板上安裝溫度傳感器 Remote/Local Temperature Sensor RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關閉: 安裝風格: 封裝 / 箱體: 設備功能:Temperature and Humidity Sensor
MAX6696AEE+T 功能描述:板上安裝溫度傳感器 Remote/Local Temperature Sensor RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關閉: 安裝風格: 封裝 / 箱體: 設備功能:Temperature and Humidity Sensor
主站蜘蛛池模板: 和林格尔县| 万盛区| 济宁市| 金溪县| 迁西县| 确山县| 吉首市| 沙湾县| 邮箱| 沂南县| 延津县| 新田县| 迁安市| 沂南县| 大埔县| 平舆县| 陕西省| 华蓥市| 南靖县| 监利县| 顺义区| 和龙市| 西林县| 出国| 辰溪县| 墨竹工卡县| 南靖县| 黄梅县| 阿勒泰市| 苍梧县| 汨罗市| 重庆市| 雅江县| 达孜县| 辽宁省| 南川市| 定日县| 宣化县| 东莞市| 射阳县| 湖口县|