700mA DC-DC Step-Down Converters
with Dual 300mA LDO in 2mm x 2mm CSP
_______________________________________________________________________________________ 3
PARAMETER
CONDITIONS
MIN   TYP   MAX  UNITS
T
A
= +25癈
    0.1     1
LX Leakage Current
V
IN1A
= V
IN1B
= V
IN2
= 5.5V,
V
LX
= 0
T
A
= +85癈
    1     
礎
p-Channel MOSFET Peak Current
Limit
V
LX
= 0
0.8    1.0    1.2     A
n-Channel MOSFET Valley
Current Limit
0.6    0.8    1.0     A
MAX8884Y_
    40     
n-Channel MOSFET
Zero-Crossing Threshold
MAX8884Z_
    60     
mA
Minimum On-Time
   0.07          祍
Minimum Off-Time
   0.06          祍
Power-Up Delay
From V
BUCK_EN
rising to V
LX
rising
    120    250    祍
LDO1, LDO2
SEL = AGND
1.764   1.800   1.836
Output Voltage V
LDO1
V
IN2
= 5.5V, I
LDO_
= 1mA;
V
IN2
= 3.4V, I
LDO_
= 100mA
SEL = IN1_
   2.800    
V
Output Voltage V
LDO2
V
IN2
= 5.5V, I
LDO_
= 1mA;
V
IN2
= 3.4V, I
LDO_
= 100mA
2.770   2.800   2.830    V
Output Current
300     
    mA
Current Limit
V
LDO_
= 0
310    450    750    mA
Dropout Voltage
I
LDO_
= 100mA, T
A
= +25癈 (V
LDO_
2.5V)
    70    200    mV
Line Regulation
V
IN2
stepped from 3.5V to 5.5V, I
LDO_
= 100mA
    2.4          mV
Load Regulation
I
LDO_
stepped from 50礎 to 200mA
    25          mV
Power-Supply Rejection
V
LDO_
/V
IN2
10Hz to 100kHz, V
LDO_
= 1.8V,
C
LDO_
= 2.2礔, I
LDO_
= 30mA
    65          dB
Output Noise
10Hz to 100kHz, V
LDO_
= 1.8V,
C
LDO_
= 2.2礔, I
LDO_
= 30mA
    26         礦
RMS
0 < I
LDO_
< 10mA
    0.1     
10mA < I
LDO_
< 200mA
    1     
Output Capacitor for Stable
Operation
200mA < I
LDO_
< 300mA
    2.2     
礔
Shutdown Output Impedance    V
LDO1_EN
= V
LDO2_EN
= 0
    100     
Power-Up Delay
From V
LDO_EN
rising to V
LDO_
output rising
    150    250    祍
REFBP
REFBP Output Voltage
0 I
REFBP
1礎
1.237   1.250   1.263    V
REFBP Supply Rejection
V
IN2
stepped from 2.55V to 5.5V
    0.2     5     mV
ELECTRICAL CHARACTERISTICS (continued)
(V
IN1A
= V
IN1B
= V
IN2
= V
LDO1_EN
= V
LDO2_EN
= V
BUCK_EN
= 3.6V. T
A
= -40癈 to +85癈, typical values are at T
A
= +25癈, unless
otherwise noted.) (Note 1)
Note 1:All devices are 100% production tested at T
A
= +25癈. Limits over the operating temperature range are guaranteed by
design.