欧美成人免费电影,国产欧美一区二区三区精品酒店,精品国产a毛片,色网在线免费观看

參數資料
型號: MC3310
廠商: Electronic Theatre Controls, Inc.
英文描述: Motion Processor
中文描述: 運動處理器
文件頁數: 47/83頁
文件大?。?/td> 1080K
代理商: MC3310
MC3310 Technical Specifications
47
host. HA0 acts as an address bit, and usually is an address bit on the bus. When the host is writing,
HA0 low indicates data and HA0 high indicates a command. When the host is reading, HAO low
indicates data and HA0 high indicates status. Read status is the only transaction allowed while
HRDY is low. During a host write the AND gate (G1:HOST INTERFACE) and two flops latch the
incoming data in the interface latches by driving ~HG1 low from the start of the write transaction
until the first negative clock transition after the first positive transition following the start of the write
cycle. This tail-biting circuit removes the requirement for hold time on the data bus.
HICTLA
Most of the control logic for the host interface is shown on schematic HICTLA. The sequencer at
the top generates HCYC one clock interval after the interface has been accessed and the host has
finished the transaction. The nature of the transaction, rd/wr, command/data, and read status is
preserved in the three flops F13, F8, and F9. Since 16 bit transfers must take place over an 8 bit bus
two transfers are required. The toggle flop is used to determine whether a cycle is the first or second
of the 2 required. The toggle flop may be initialized to the 0 state, which indicates that this is the
first transfer (high byte), by the CP writing a one to host status bit 15. This status bit is read by the
host as the HRDY bit and is not writable by the CP. In addition flop F12 and the associated gating
determine if the present command transaction is the first or second byte of a command. If the
toggle flop gets into the wrong state due to a missed or aborted transfer the next command will set it
back to the correct state. A host write or a CP write, DSIW, enable REG1 and REG2 on the HOST
INTERFACE schematic discussed previously. A host data write generates ~ENHD1 and
~ENHD2 for the data registers on the DATAREG schematic. For host writes ~EN2, ~EN1,
~ENHD2, and ~ENHD1 are also determined by the state of the toggle flop using HIEN and
LOEN. 1CMD is used in this logic to ensure correct behavior when the command is correcting the
state of the toggle. The logic at the bottom of the page generates the CP interrupt, the HRDY and
the HCMDFL. The HCMDFL is used in the CP status to indicate a command. DSIW, the CP
writing to REG1 and REG2 on the HOST INTERFACE schematic clears the interrupt and reasserts
HRDY. HRDY is de-asserted during all host transactions except read status, and stays de-asserted
until the CP has completed the DSIW cycle that clears the interrupt and reasserts HRDY. As
mentioned previously data transfers to and from the host use the data registers and do not interrupt
the CP. The CP knows the number of data transfers that must take place after decoding the
command. It places this number, 0-3, in the 2 least significant bits of the host status register,
HST[1:0]. These become DPNT[1:0] on this page of the schematic and enable an interrupt at 0 for a
read and 1 or 0 for a write. The CP always leaves these bits at 0 unless setting up a multiple word
data transfer. If INTEN is true and LRDST, latched read status, is false, HCYC will generate an
interrupt to the CP. This will also hold HRDY false until after the CP writes to the interface register,
DSIW, thereby generating ~CLRFLGS.
IOPIL8 4
The CP interface is shown in sheet IOPIL8 4. The incoming data DSD[15:0] is latched in the
transparent latches when ~DG1 and ~DG2 go high. This occurs at the completion of a write from
the CP to the I/O chip. The latched data DSI[15:8] and DSI[7:0] go to schematic IOPIL8 1 and
IOPIL16 5. DSI[7:0] also goes to IOPIL16 2. Data from the interface to the CP, DO[15:8] and
DO[7:0] is enabled onto the CP bus, DSD[15:0], by DOE2 and DOE1 respectively. The output
latches, which present the data during a CP read, are always transparent because GOUT is connected
to VDD. The latched I/O in the Actel part contains both input and output latches. The output
latches could be omitted in the CP interface if a different CPLD or FPGA does not have this feature.
The two incoming CP address bits CPA0 and CPA1 are also latched using ~DG3. The 20CK signal
is the clock for the CP. This is a 20 MHz clock derived from a 40 MHz clock input.
相關PDF資料
PDF描述
MC33121 LOW VOLTAGE SUBSCRIBER LOOP INTERFACE CIRCUIT
MC33121FN LOW VOLTAGE SUBSCRIBER LOOP INTERFACE CIRCUIT
MC33121P LOW VOLTAGE SUBSCRIBER LOOP INTERFACE CIRCUIT
MC33151 High Speed Dual MOSFET Drivers
MC33151DR2 High Speed Dual MOSFET Drivers
相關代理商/技術參數
參數描述
MC3310-011-01 制造商:SPC Multicomp 功能描述:SWITCH DPST LATCHING BLACK 制造商:SPC Multicomp 功能描述:SWITCH, DPST, LATCHING, BLACK 制造商:SPC Multicomp 功能描述:SWITCH, PUSHBUTTON, DPST, 16A, 250V; Contact Configuration:DPST; Switch Operation:On-Off; Contact Voltage AC Nom:250V; Contact Current Max:16A; Actuator Style:Rectangular; Switch Terminals:Quick Connect, Solder; Circuitry:DPST ;RoHS Compliant: Yes
MC3310-031-01 制造商:SPC Multicomp 功能描述:SWITCH DPST MOM BLACK 制造商:SPC Multicomp 功能描述:SWITCH, DPST, MOM, BLACK
MC3310-051-02 制造商:SPC Multicomp 功能描述:SWITCH DPST LATCHING RED 制造商:SPC Multicomp 功能描述:SWITCH, DPST, LATCHING, RED 制造商:SPC Multicomp 功能描述:SWITCH, PUSHBUTTON, DPST, 16A, 250V; Contact Configuration:DPST; Switch Operation:On-Off; Contact Voltage AC Nom:250V; Contact Current Max:16A; Actuator Style:Rectangular; Switch Terminals:Quick Connect, Solder; Circuitry:DPST ;RoHS Compliant: Yes
MC3310-051-05 制造商:SPC Multicomp 功能描述:SWITCH DPST LATCHING GREEN 制造商:SPC Multicomp 功能描述:SWITCH, DPST, LATCHING, GREEN 制造商:SPC Multicomp 功能描述:SWITCH, PUSHBUTTON, DPST, 16A, 250V; Contact Configuration:DPST; Switch Operation:On-Off; Contact Voltage DC Nom:250V; Contact Current Max:16A; Actuator Style:Rectangular; Switch Terminals:Quick Connect, Solder; Circuitry:DPST ;RoHS Compliant: Yes
MC33102 制造商:MOTOROLA 制造商全稱:Motorola, Inc 功能描述:Amplifiers and Comparators
主站蜘蛛池模板: 腾冲县| 内江市| 巴东县| 德格县| 青浦区| 中超| 镇安县| 武定县| 井冈山市| 增城市| 自贡市| 金塔县| 大英县| 金沙县| 凤阳县| 百色市| 东宁县| 栖霞市| 文山县| 合作市| 平山县| 晋江市| 克拉玛依市| 蕲春县| 张掖市| 吴川市| 揭西县| 会东县| 鹿泉市| 东乡县| 平谷区| 辰溪县| 玉林市| 双柏县| 竹北市| 古田县| 苏尼特左旗| 三穗县| 温泉县| 洛川县| 法库县|