26
50
30
63
40
100
63
250
160
400
200
630
220
1000
250
0.001
–10.0
0.001
–82
0.001
–56
0.001
–22
0.001
–10
0.001
–4.7
0.001
–1.5
±20%, ±10% standard, ±5%.
–55 ... +100°C
Above +85°C DC and AC voltage derating
is 1.25%/°C.
+85°C
IEC 60068-1, 55/100/56
DIN 40040, FME
–55 ... +100°C
Average relative humidity
≤
75 %
RH = 95% for 30 days per year.
RH = 85% for further days limited by
average value per year, occasional slight
condensation permitted.
1.6 x U
R
VDC for 2s
Max. 2% after a 2 year storage period at a
temperature of +10 ... +40°C and a relative
humidity of 40...60%.
Operational life > 200 000 h.
Failure rate < 3 FIT, T = +40°C, U = 0.5 x U
R
.
Failure criteria according to DIN 44122.
dU/dt according to article table.
For peak to peak voltages lower than
rated voltage (U
< U
), the specified
dU/dt can be multiplied by the factor U
R
/U
PP
.
+400 (±200) ppm/°C at 1 kHz
Approximately 6 nH/cm for the total length
of capacitor winding and the leads.
MMK
Metallized polyester
According to CECC 30401-042, IEC 60384-2, DIN 44122
TYPIC AL APPLIC ATIONS
Bypassing, signal coupling. General
purpose for highest reliability.
C ONS TRUC TION
Metallized polyester film capacitor. Radial
leads of tinned wire are electrically welded
to the contact metal layer on the ends of
the capacitor winding. Encapsulation in
self-extinguishing material meeting the
requirements of UL 94V-0.
TE C HNIC AL DATA
L
H
B
p
l
d
0.5
b
p
d
std I max I
b
5.0 ± 0.4
7.5 ± 0.4
10.0 ± 0.4
15.0 ± 0.4
22.5 ± 0.4
27.5 ± 0.4
37.5 ± 0.5
0.5
0.6
0.6
0.8
0.8
0.8
1.0
4
+1
4
+1
4
+1
4
+1
4
+1
4
+1
4
+1
30
30
30
30
30
30
30
± 0.4
± 0.4
± 0.4
± 0.4
± 0.4
± 0.4
± 0.7
Rated voltage U
R
, VDC
Rated voltage U
R
, VAC
Capacitance, μF
Capacitance tolerance
Category temperature range
Voltage derating
Rated temperature
Climatic category
Test voltage
Capacitance drift
Reliability
Maximum pulse steepness:
Temperature coefficient
Self inductance
NE W OPTIMIZE D S E RIE S IN S MALLE R DIME NS IONS
There are now many parts in the MMK series in smaller sizes than before. The capacitance
range has also been extended. These parts are marked with *in the article table. The size
codes for the bigger old parts are shown in the article table next to the new article code.
Table with all size codes on page 18.