欧美成人免费电影,国产欧美一区二区三区精品酒店,精品国产a毛片,色网在线免费观看

參數資料
型號: MPSH11RL1
廠商: ON SEMICONDUCTOR
元件分類: 小信號晶體管
英文描述: UHF BAND, Si, NPN, RF SMALL SIGNAL TRANSISTOR, TO-92
封裝: PLASTIC, TO-226AA, 3 PIN
文件頁數: 24/33頁
文件大?。?/td> 291K
代理商: MPSH11RL1
9–19
Reliability and Quality Assurance
Motorola Small–Signal Transistors, FETs and Diodes Device Data
147
148
149
150
151
152
153
154
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39 40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
0
1
2
3
4
5
6
7
UCL = 152.8
= 150.4
LCL = 148.0
UCL = 7.3
= 3.2
LCL = 0
X
R
Figure 4. Example of Process Control Chart Showing Oven Temperature Data
Where D4, D3, and A2 are constants varying by sample size,
with values for sample sizes from 2 to 10 shown in the
following partial table:
n234
56789
10
D4
3.27
2.57
2.28
2.11
2.00
1.92
1.86
1.82
1.78
D3
*
0.08
0.14
0.18
0.22
A2
1.88
1.02
0.73
0.58
0.48
0.42
0.37
0.34
0.31
*For sample sizes below 7, the LCLR would technically be a negative number;
in those cases there is no lower control limit; this means that for a subgroup size
6, six ‘‘identical’’ measurements would not be unreasonable.
Control charts are used to monitor the variability of critical
process parameters. The R chart shows basic problems with
piece to piece variability related to the process. The X chart can
often identify changes in people, machines, methods, etc. The
source of the variability can be difficult to find and may require
experimental design techniques to identify assignable causes.
Some general rules have been established to help determine
when a process is OUT–OF–CONTROL. Figure 5 shows a
control chart subdivided into zones A, B, and C corresponding
to 3 sigma, 2 sigma, and 1 sigma limits respectively. In Figures
6 through 9 four of the tests that can be used to identify
excessive variability and the presence of assignable causes
are shown. As familiarity with a given process increases, more
subtle tests may be employed successfully.
Once the variability is identified, the cause of the variability
must be determined. Normally, only a few factors have a
significant impact on the total variability of the process. The
importance of correctly identifying these factors is stressed in
the following example. Suppose a process variability depends
on the variance of five factors A, B, C, D, and E. Each has a
variance of 5, 3, 2, 1, and 0.4, respectively.
Since:
σ tot =
σ A2 + σ B2 + σ C2 + σ D2 + σ E2
σ tot =
52 + 32 + 22 + 12 +(0.4)2 = 6.3
If only D is identified and eliminated, then:
σ tot =
52 + 32 + 22 + (0.4)2 = 6.2
This results in less than 2% total variability improvement. If
B, C, and D were eliminated, then:
σ tot =
52 + (0.4)2 = 5.02
This gives a considerably better improvement of 23%. If
only A is identified and reduced from 5 to 2, then:
σ tot =
22 + 32 + 22 + 12 + (0.4)2 = 4.3
Identifying and improving the variability from 5 to 2 yields a
total variability improvement of nearly 40%.
Most techniques may be employed to identify the primary
assignable cause(s). Out–of–control conditions may be
correlated to documented process changes. The product may
be analyzed in detail using best versus worst part comparisons
or Product Analysis Lab equipment. Multi–variance analysis
can be used to determine the family of variation (positional,
critical, or temporal). Lastly, experiments may be run to test
theoretical or factorial analysis. Whatever method is used,
assignable causes must be identified and eliminated in the
most expeditious manner possible.
After assignable causes have been eliminated, new control
limits are calculated to provide a more challenging variablility
criteria for the process. As yields and variability improve, it may
become more difficult to detect improvements because they
become much smaller. When all assignable causes have been
eliminated and the points remain within control limits for 25
groups, the process is said to in a state of control.
相關PDF資料
PDF描述
MPSH11RLRA UHF BAND, Si, NPN, RF SMALL SIGNAL TRANSISTOR, TO-92
MPSH11RL UHF BAND, Si, NPN, RF SMALL SIGNAL TRANSISTOR, TO-92
MPSH11RLRE UHF BAND, Si, NPN, RF SMALL SIGNAL TRANSISTOR, TO-92
MPSH81D74Z VHF BAND, Si, PNP, RF SMALL SIGNAL TRANSISTOR, TO-92
MPSH81D27Z VHF BAND, Si, PNP, RF SMALL SIGNAL TRANSISTOR, TO-92
相關代理商/技術參數
參數描述
MPSH16-D20-120V 制造商:Black Box Corporation 功能描述:Outlet-Managed PDU, 16-Outlet, Dual-Circuit, 120 VAC, 20-Amp
MPSH16-D20-120VT 制造商:Black Box Corporation 功能描述:16 OUTLET 120V 20A DUAL CIRCUIT OUTLET METERING
MPSH16-D20-120V-W1 制造商:Black Box Corporation 功能描述:1 YEAR WARRANTY FOR MPSH16-D20-120V
MPSH16-D20-120V-W3 制造商:Black Box Corporation 功能描述:3 YEAR WARRANTY FOR MPSH16-D20-120V
MPSH16-D20-208+V 制造商:Black Box Corporation 功能描述:Outlet-Managed PDU, 16-Outlet, Dual-Circuit, 208+ VAC, 20-Amp
主站蜘蛛池模板: 蓝田县| 龙山县| 温州市| 北京市| 辽阳市| 如皋市| 抚远县| 泽库县| 平塘县| 黑山县| 兴安县| 承德市| 壶关县| 商都县| 盐亭县| 浏阳市| 黔西县| 越西县| 独山县| 荥阳市| 肇庆市| 扶风县| 通河县| 靖江市| 原阳县| 高清| 体育| 大方县| 平泉县| 蒙自县| 杨浦区| 普陀区| 阳高县| 丘北县| 郧西县| 高邑县| 南华县| 大宁县| 哈尔滨市| 铜山县| 襄垣县|