60W Open Frame Single Output
NAD-600X series
Feature:
l
90 to 264Vac universal input range.
l
UL/CUL, TUV, CB safety meet(approval).
l
EMI/RFI meet VDE & FCC limit B.
l
Low cost & compact size.
l
60Watts in127
×
76.2
×
44.1mm Size.
l
2 Year Warranty.
Specifications
: typical at nominal line, full load at 25
°
C.
Input Specifications:
Input voltage:
90 to 264Vac
Input Frequency
: 47 Hz to 63Hz
Input inrush current:
20A at 115Vac
40A at 230Vac
Date: Sep 19,2003 13
General Specifications:
Efficiency:
75% typical at full load
Hold-up time:
15ms @ 115Vac full load
EMI/RFI:
VDE & FCC Class B limits
Dielectric Withstand:
Input/output: 3000Vac
Input/Ground: 1500Vac
Safety Meet(Approval):
UL/CUL UL60950
TUV EN60950
CB IEC950
Switching frequency:
20kHz(reference)
Weight:
350g
Earth leakage:
0.2mA max @ 115Vac
0.4mA max @ 230Vac
Output Specifications:
Output Rating:
See Selection table
Output Voltage Accuracy :
±
5% max.
Line Regulation:
±
1% max.
Load Regulation:
±
1% max.
(Full to half load)
Transient Response
±
1% max.dev.
(Full to half load) 500uS recovery
Temperature Coefficient:
±
0.04% /
°
C
Operating temperature:
0 to +50
°
C
Ripple & Noise:
1% P-P max.
Protections:
b. Over voltage protection
c. Over power protection
d. Short circuit protection
Note:
1.
Vibration test: Three orthogonal axes, random vibration, 10 minutes for each axis.
2.
Maximum output power is 60W.
3.
At least 20% of load is required to obtain stable regulation.
4.
Ripple & noise test method is measured at output terminal across a 0.1uF ceramic cap
& a 10uF tantalum or electrolytic cap in parallel with a 20MHz bandwidth oscilloscope
directly.
Please refer the safety approval status on appendix 1, For latest safety approval status
Please consult YCL or visit
www.ycl.com.tw
MTBF:
100,000hours(MIL-HDBK-217F)
Environmental Specifications:
Storage temperature:
-20 to +85
°
C
Humidity:
5 to 95 % RH non-condensing
Vibration:
2.4G , 5 to 500Hz
Cooling:
Free air convection