198
250 VAC, 50/60 Hz
0.022
–
0.1 μF
± 20%
100
± 30%
1000 V
–
40 to +85
°
C
40/085/56/B
S, N, D, FI, VDE, SEV, UL
The series resistance is defined at 100 kHz
≥
1000 M
Measured at 500 VDC after 2 min, +23
°
C
Max 12 A repetitive. Max 20 A peak for occasional
transients.
The 100% screening factory test is carried out at
3000 VDC. The voltage level is selected to meet the
requirements in applicable equipment standards. All
electrical characteristics are checked after the test.
Recommended voltage
≤
1000 VDC.
The average losses may reach 0.5 W provided the
surface temperature does not exceed + 85
°
C. For
maximum permitted power dissipation vs temperature,
see derating curves.
Curve
Dimensions
1
1
2
3
4
B = 7.3
B = 8.5
B = 9.0
B = 11.3
B = 10.6
PMR210
RC unit, class X1, metallized paper with integrated resistor
0.022
–
0.1 μF, 100
, 250 VAC, +85
°
C
TYPICAL APPLICATIONS
CONSTRUCTION
TECHNICAL DATA
RC unit for use in DC and AC applications
for:
–
contact protection
–
interference suppression of contacts
–
transient suppression
Single layer metallized paper, encapsulated
and impregnated in self-extinguishing
material meeting the requirements of UL
94V-0. The resistance in the metal layer is
utilized as series resistance, integrated
resistor.
Rated voltage
Capacitance range
Capacitance tolerance
Resistance range
Resistance tolerance
Peak pulse voltage
Temperature range
Climatic category
Approvals
Series resistance
Insulation resistance
Pulse current
Test voltage between
terminals
In DC applications
Power ratings
RC unit for safety applications.
Small dimensions
High dU/dt capability.
Self-extinguishing encapsulation. The
material is recognized acc. to UL 94 V-0
Good resistance to ionisation due to
impregnated dielectric.
Excellent self-healing properties. Ensures
long life even when subjected to frequent
overvoltages.
The impregnated paper ensures excellent
stability giving outstanding reliability
properties, especially in applications
having continuous operation.
L
H
B
p ± 0.5
l
d
l: standard: 30 +5/-0 mm
option: short leads, tolerance +0/-1 mm
(standard 6 mm, code R06)
Other lead lengths on request.
C
R
d = 0.8 for p = 15.2 and 20.3
1.0 for p = 25.4
40
T
amb
50
60
70
80
85
°
C
0.5
P
max
W
0
1
2
Maximum allowable power dissipation vs
ambient temperature and case sizes.
3
4