參數資料
型號: Q67100-Q960
廠商: SIEMENS AG
英文描述: 1M x 36-Bit Dynamic RAM Module (2M x 18-Bit Dynamic RAM Module)
中文描述: 100萬× 36位動態RAM模塊(2米× 18位動態隨機存儲器模塊)
文件頁數: 13/53頁
文件大小: 418K
代理商: Q67100-Q960
HYB 39S64400/800/160BT(L)
64-MBit Synchronous DRAM
Data Book
13
12.99
command is necessary. A minimum
t
RC
time is required between two automatic refreshes in a burst
refresh mode. The same rule applies to any access command after the automatic refresh operation.
The chip has an on-chip timer and the Self Refresh mode is available. It enters the mode when RAS,
CAS, and CKE are low and WE is high at a clock timing. All of external control signals including the
clock are disabled. Returning CKE to high enables the clock and initiates the refresh exit operation.
After the exit command, at least one
t
RC
delay is required prior to any access command.
DQM Function
DQM has two functions for data I/O read and write operations. During reads, when it turns to “high”
at a clock timing, data outputs are disabled and become high impedance after two clock delay (DQM
Data Disable Latency
t
DQZ
). It also provides a data mask function for writes. When DQM is activated,
the write operation at the next clock is prohibited (DQM Write Mask Latency
t
DQW
= zero clocks).
Suspend Mode
During normal access mode, CKE is held high enabling the clock. When CKE is low, it freezes the
internal clock and extends data read and write operations. One clock delay is required for mode
entry and exit (Clock Suspend Latency
t
CSL
).
Power Down
In order to reduce standby power consumption, a power down mode is available. All banks must be
precharged and the necessary Precharge delay (
t
RP
) must occur before the SDRAM can enter the
Power Down mode. Once the Power Down mode is initiated by holding CKE low, all of the receiver
circuits except CLK and CKE are gated off. The Power Down mode does not perform any refresh
operations, therefore the device can’t remain in Power Down mode longer than the Refresh period
(
t
REF
) of the device. Exit from this mode is performed by taking CKE “high”. One clock delay is
required for mode entry and exit.
Auto Precharge
Two methods are available to precharge SDRAMs. In an automatic precharge mode, the CAS
timing accepts one extra address, CA10, to determine whether the chip restores or not after the
operation. If CA10 is high when a Read Command is issued, the
Read with Auto-Precharge
function is initiated. If CA10 is high when a Write Command is issued, the
Write with Auto-
Precharge
function is initiated. The SDRAM automatically enters the precharge operation two
clocks after the last data in.
Precharge Command
There is also a separate precharge command available. When RAS and WE are low and CAS is
high at a clock timing, it triggers the precharge operation. Three address bits, BA0, BA1 and A10 are
used to define banks as shown in the following list. The precharge command can be imposed one
clock before the last data out for CAS latency = 2 and two clocks before the last data out for CAS
latency = 3. Writes require a time delay
t
WR
from the last data out to apply the precharge command.
相關PDF資料
PDF描述
Q67100-Q961 1M x 36-Bit Dynamic RAM Module (2M x 18-Bit Dynamic RAM Module)
Q67100-Q954 2M x 36-Bit Dynamic RAM Module
Q67100-Q955 2M x 36-Bit Dynamic RAM Module
Q67100-Q956 2M x 36-Bit Dynamic RAM Module
Q67100-Q850 512kx8-Bit Dynamic RAM
相關代理商/技術參數
參數描述
Q67100-Q961 制造商:INFINEON 制造商全稱:Infineon Technologies AG 功能描述:1M x 36-Bit Dynamic RAM Module (2M x 18-Bit Dynamic RAM Module)
Q67100-Q971 制造商:INFINEON 制造商全稱:Infineon Technologies AG 功能描述:4M x 1-Bit Dynamic RAM
Q67100-Q973 制造商:INFINEON 制造商全稱:Infineon Technologies AG 功能描述:1M x 4-BIT DYNAMIC RAM LOW POWER 1M x 4-BIT DYNAMIC RAM
Q67100-Q976 制造商:INFINEON 制造商全稱:Infineon Technologies AG 功能描述:2M x 32-Bit Dynamic RAM Module
Q67100-Q977 制造商:INFINEON 制造商全稱:Infineon Technologies AG 功能描述:2M x 32-Bit Dynamic RAM Module
主站蜘蛛池模板: 察隅县| 鹿邑县| 陵水| 镇雄县| 邯郸市| 龙里县| 香格里拉县| 兰州市| 锡林郭勒盟| 商南县| 苍梧县| 始兴县| 江源县| 仪陇县| 建宁县| 白朗县| 丰县| 剑阁县| 财经| 杂多县| 金寨县| 太白县| 宽甸| 渑池县| 麻栗坡县| 南投市| 霍林郭勒市| 岳池县| 水城县| 剑阁县| 边坝县| 洛浦县| 屏东市| 凤山市| 阳江市| 界首市| 运城市| 美姑县| 砀山县| 噶尔县| 朝阳市|