144
www.recom-international.com
April-2005
75 Watt
Isolated
Single
&
Dual Output
INNOLINE
DC/DC-Converter
RP75-S_DI
Series
●
Single Output up to 20A
Dual Outputs Total Current up to 15A
up to 100% Load Imblance
●
Input/Output 1.6kVDC Isolation
●
Adjustable Output Voltage, Independently
Regulated Outputs
●
No Minimum Load
●
Industry Standard Footprint
●
Halt Tested
●
Compact 61.0 x 57.91 x 12.7mm Package
●
High Efficiency to 90%
Features
Selection Guide
Notes:
Part Input Output Output Line
Number Voltage Voltage Current Regulation Regulation Current
Single Output
(VDC) (VDC) (A) (mV) (mV) (A) %
Load Input Efficiency
RP75-481.8S 36 – 75 1.8 20 4 6 0.915 86
RP75-482.5S 36 – 75 2.5 20 5 8 1.255 88
RP75-483.3S 36 – 75 3.3 20 7 10 1.618 90
RP75-4805S 36 – 75 5 15 10 15 1.838 90
RP75-4815S 36 – 75 15 5 30 45 1.860 90
Part Input Output Output Line
Number Voltage Voltage Current Regulation Regulation
V1 V2 I1 I2
Dual Output
(VDC) (VDC) (VDC) (A) (A) (mV) (mV) %
Load Efficiency
RP75-483.305DI 36 – 75 5 3.3 15 15 7/10 10/15 88
RP75-483.32.5DI 36 – 75 3.3 2.5 15 15 7/5 10/8 81
RP75-48051.8DI 36 – 75 5 1.8
15 15 10/4 10/15 85
RP75-483.31.8DI 36 – 75 3.3 1.8 15 15 7/4 10/6 81
1. Maximum output deviation is 10% inclusive of remote sense. If remote sense is not being used,
the +Vsense should be connected to its corresponding +Vout and likewise the -Vsense should be connected
to its corresponding -Vout..
2. Measured with a 1uF M/C and a 10uF M/C(for dual outputs) or 1uF M/C and a 10uF T/C(for single outputs).
3.An external filter capacitor is required for normal operation.The capacitor should be capable of handing 1A ripple
current for 48V models. RECOM suggest: Nippon chemi-con KMF series, 220μF/100V, ESR 90m
.
4.The negative / positive logic and length are optional ( see table ).The pin voltage is referenced to negative input.
5. BELLCORE TR-NWT-000332. Case I: 50% Stress,Temperature at Tc=40°C.
(Ground fixed and controlled environment)
6. Heat sink is optional and P/N: 7G-0021, 7G-0022, 7G-0023, 7G-0024.
7.The RP75 meets level A and level B conducted emissions only with external components connected before
the input pin to the converter.
8. Maximum value at nominal input voltage and full load.
9. Single:Typical value at nominal input voltage and full load.
Dual:The efficiency test condition: Nominal input voltage and both outputs current are 7.5A.
10. BASEPLATE GROUNDING:Base-plate should be grounded at one of the four screw bolts prior to operation.
11.The converter is provided by basic insulation.
12.“N” for Negative remote ON/OFF.
13.“P” for
Positive
remote ON/OFF.