1
Rating
Value
Units
Power Supply and All Input/Output Pins
-0.3 to +4.0
V
Non-Operating Case Temperature
-50 to +100
o
C
Soldering Temperature (10 seconds)
250
o
C
Absolute Maximum Ratings
Electrical Characteristics (typical values given for 3.0 Vdc power supply, 25
o
C)
Characteristic
Sym
Notes
Minimum
Typical
Maximum
Units
Operating Frequency
f
O
433.72
434.12
MHz
Modulation Type
OOK/ASK
Data Rate
19.2
kbps
Receiver Performance, High Sensitivity Mode
Sensitivity, 1.2 kbps, 10-3 BER, AM Test Method
1
-110.5
dBm
Sensitivity, 1.2 kbps, 10-3 BER, Pulse Test Method
1
-104.5
dBm
Current, 1.2 kbps (R
PR
= 330 K)
2
2.9
mA
Sensitivity, 2.4 kbps, 10-3 BER, AM Test Method
1
-109
dBm
Sensitivity, 2.4 kbps, 10-3 BER, Pulse Test Method
1
-103
dBm
Current, 2.4 kbps (R
PR
= 330 K)
2
3.0
mA
Sensitivity, 19.2 kbps, 10-3 BER, AM Test Method
1
-105
dBm
Sensitivity, 19.2 kbps, 10-3 BER, Pulse Test Method
1
-99
dBm
Current, 19.2 kbps
3.1
mA
Receiver Performance, Low Current Mode
Sensitivity, 1.2 kbps, 10-3 BER, AM Test Method
1
-104
dBm
Sensitivity, 1.2 kbps, 10-3 BER, Pulse Test Method
1
-98
dBm
Current, 1.2 kbps (R
PR
= 2000 K)
2
1.65
mA
RX5500
433.92 MHz
Hybrid
Receiver
Designed for Short-Range Wireless Control Applications
3 V, Low Current Operation plus Sleep Mode
Characterized for Automotive Applications
High EMI Rejection Capability
The RX5500 hybrid receiver is ideal for short-range wireless control applications where robust
operation, small size, low power consumption and low cost are required. The RX5500 employs
RFM’s amplifier-sequenced hybrid (ASH) architecture to achieve this unique blend of character-
istics. All critical RF functions are contained in the hybrid, simplifying and speeding design-in.
The RX5500 is sensitive and stable. A wide dynamic range log detector provides robust perfor-
mance in the presence of on-channel interference or noise. Two stages of SAW filtering provide
excellent receiver out-of-band rejection. The RX5500 generates virtually no RF emissions, facili-
tating compliance with ETSI I-ETS 300 220 and similar regulations.