Si APD
S8890 series
HAMAMATSU PHOTONICS K.K., Solid State Division
1126-1 Ichino-cho, Higashi-ku, Hamamatsu City, 435-8558 Japan, Telephone: (81) 53-434-3311, Fax: (81) 53-434-5184, www.hamamatsu.com
U.S.A.: Hamamatsu Corporation: 360 Foothill Road, P.O.Box 6910, Bridgewater, N.J. 08807-0910, U.S.A., Telephone: (1) 908-231-0960, Fax: (1) 908-231-1218
Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49) 8152-375-0, Fax: (49) 8152-265-8
France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: 33-(1) 69 53 71 00, Fax: 33-(1) 69 53 71 10
United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, United Kingdom, Telephone: (44) 1707-294888, Fax: (44) 1707-325777
North Europe: Hamamatsu Photonics Norden AB: Smidesvgen 12, SE-171 41 Solna, Sweden, Telephone: (46) 8-509-031-00, Fax: (46) 8-509-031-01
Italy: Hamamatsu Photonics Italia S.R.L.: Strada della Moia, 1/E, 20020 Arese, (Milano), Italy, Telephone: (39) 02-935-81-733, Fax: (39) 02-935-81-741
Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions.
Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein.
Type numbers of products listed inthe specification sheets or supplied as samples may have a suffix "(X)" which means tentative specifications or a suffix "(Z)"
which means developmental specifications. 2010 Hamamatsu Photonics K.K.
Cat. No. KAPD1010E02
Jan. 2010 DN
3
s Dimensional outline (unit: mm)
KAPDA0024EA
S8890-02/-05/-10/-15
Chip position accuracy with
respect to the cap center
X, Y
≤±0.3
The glass window may extend a
maximum of 0.2 mm beyond the
upper surface of the cap
(2.5)
(20)
4.2
±
0.2
0.4
MAX.
5.9 ± 0.1
5.08 ± 0.2
S8890-02
0.2
TYPE No.
a
S8890-05
0.5
S8890-10
1.0
S8890-15
1.5
Y
X
8.1 ± 0.1
9.1 ± 0.2
1.5 MAX.
ACTIVE AREA
a
PHOTOSENSITIVE
SURFACE
CASE
0.45
LEAD
KAPDA0025EA
S8890-30
Chip position accuracy with
respect to the cap center
X, Y
≤±0.4
The glass window may extend a
maximum of 0.2 mm beyond the
upper surface of the cap
(2.5)
(15)
4.9
±
0.2
INDEX MARK
1.4
PHOTOSENSITIVE
SURFACE
0.5
MAX.
13.9 ± 0.2
12.35 ± 0.1
10.5 ± 0.1
7.5 ± 0.2
1.0 MAX.
ACTIVE AREA
3.0
CASE
0.45
LEAD
Y